747 research outputs found

    New Active Optical Technique Developed for Measuring Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

    Get PDF
    Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a uniformly thick sheet of semitransparent polymer such as Kapton H polyimide, then as atomic oxygen erodes the polymer, the short-circuit current from the photodiode will increase in an exponential manner with fluence. This nonlinear response with fluence results in a lack of sensitivity for measuring low atomic oxygen fluences. However, if one uses a variable-thickness polymer or carbon sample, which is configured as shown in the preceding figure, then a linear response can be achieved for opaque materials using a parabolic well for a circular geometry detector or a V-shaped well for a rectangular-geometry detector. Variable-thickness samples can be fabricated using many thin polymer layers. For semitransparent polymers such as Kapton H polyimide, there is an initial short-circuit current that is greater than zero. This current has a slightly nonlinear dependence on atomic oxygen fluence in comparison to opaque materials such as black Kapton as shown in the graph. For this graph figure, the total thickness of Kapton H was assumed to be 0.03 cm. The photodiode short-circuit current shown in the graph was generated on the basis of preliminary measurements-a total reflectance rho of 0.0424 and an optical absorption coefficient a of 146.5 cm(sup -1). In addition to obtaining on-orbit data, the advantage of this active erosion and erosion yield measurement technique is its simplicity and reliance upon well-characterized fluence witness materials as well as a nearly linear photodiode short-circuit current dependence upon atomic oxygen fluence. The optical technique is useful for measuring either atomic oxygen fluence or erosion, depending on the information desired. To measure the atomic oxygen erosion yield of a test material, one would need to have two photodiode sensors, one for the test material and one that uses a known erosion yield material (such as Kapton) to measure the atomic oxygen fluence

    Thermal Performance Testing of Order Dependancy of Aerogels Multilayered Insulation

    Get PDF
    Robust multilayer insulation systems have long been a goal of many research projects. Such insulation systems must provide some degree of structural support and also mechanical integrity during loss of vacuum scenarios while continuing to provide insulative value to the vessel. Aerogel composite blankets can be the best insulation materials in ambient pressure environments; in high vacuum, the thermal performance of aerogel improves by about one order of magnitude. Standard multilayer insulation (MU) is typically 50% worse at ambient pressure and at soft vacuum, but as much as two or three orders of magnitude better at high vacuum. Different combinations of aerogel and multilayer insulation systems have been tested at Cryogenics Test Laboratory of NASA Kennedy Space Center. Analysis performed at Oak Ridge National Laboratory showed an importance to the relative location of the MU and aerogel blankets. Apparent thermal conductivity testing under cryogenic-vacuum conditions was performed to verify the analytical conclusion. Tests results are shown to be in agreement with the analysis which indicated that the best performance is obtained with aerogel layers located in the middle of the blanket insulation system

    Communications Biophysics

    Get PDF
    Contains reports on five research projects.National Institutes of Health (Grant 5 P01 GM14940-03)National Institutes of Health (Grant 5 TOl GM01555-03)National Aeronautics and Space Administration (Grant NGL 22-009-304

    Communications Biophysics

    Get PDF
    Contains research objectives, summary of research and reports on four research projects.National Institutes of Health (Grant 5 P01 GM14940-05)National Institutes of Health (Grant 5 TOl GM01555-05)National Aeronautics and Space Administration (Grant NGL 22-009-304)B-D ElectrodyneBoston City Hospital Purchase Order 1065

    The Presence of Air in the Vein Branches Gate of Hypovolemia, Case Study

    Get PDF
    The roentgenographic finding hepatic—portal venous gas (HPVG) has been reported extensively in the pediatric and radiology literature. The surgical implications and clinical significance have yet to be fully defined. HPVG appears as a branching radiolucency extending to within 2 cm of the liver capsule. HPVG is associated with necrotic bowel (72%), ulcerative colitis (8%), intra abdominal abscess (6%), small bowel obstruction (3%), and gastric ulcer (3%). Mucosal damage, bowel distention and sepsis predispose to HPVG. The current mortality rate of 75% represents an improvement from previous experience. Analysis of survivors indicates that the finding of HPVG requires urgent surgical exploration except when it is observed in patients with stable ulcerative colitis. In our case the presentation of HPVG is finding at the patient after trauma.. The Patient LL, age 57 appears in front of the emergency service military hospital in serious condition after a trauma with abdominal pain,. In examining the CT the presence of gas in the portal system.Keywords: HPVG, ECN, CT examination, Ischemia, SMA Thrombosis, embolism, etc

    Electrocatalytic Assisted Performance Enhancement for the Na-S Battery in Nitrogen-Doped Carbon Nanospheres Loaded with Fe.

    Get PDF
    Room temperature sodium-sulfur batteries have been considered to be potential candidates for future energy storage devices because of their low cost, abundance, and high performance. The sluggish sulfur reaction and the "shuttle effect" are among the main problems that hinder the commercial utilization of room temperature sodium-sulfur batteries. In this study, the performance of a hybrid that was based on nitrogen (N)-doped carbon nanospheres loaded with a meagre amount of Fe ions (0.14 at.%) was investigated in the sodium-sulfur battery. The Fe ions accelerated the conversion of polysulfides and provided a stronger interaction with soluble polysulfides. The Fe-carbon nanospheres hybrid delivered a reversible capacity of 359 mAh·g-1 at a current density of 0.1 A·g-1 and retained a capacity of 180 mAh·g-1 at 1 A·g-1, after 200 cycles. These results, combined with the excellent rate performance, suggest that Fe ions, even at low loading, are able to improve the electrocatalytic effect of carbon nanostructures significantly. In addition to Na-S batteries, the new hybrid is anticipated to be a strong candidate for other energy storage and conversion applications such as other metal-sulfur batteries and metal-air batteries

    Communications Biophysics

    Get PDF
    Contains research objectives, summary of research and reports on three research projects.National Institutes of Health (Grant 5 PO1 GM14940-04)National Institutes of Health (Grant 5 TOl GM01555-04)National Aeronautics and Space Administration (Grant NGL 22-009-304

    4-(1H-Tetra­zol-5-yl)benzoic acid monohydrate

    Get PDF
    The asymmetric unit of the title compound, C8H6N4O2·H2O, consists of one 4-(1H-tetra­zol-5-yl)benzoic acid mol­ecule and one water mol­ecule. Hydrogen-bonding and π–π stacking (centroid–centroid distance between tetra­zole and benzene rings = 3.78 Å) inter­actions link the mol­ecules into a three-dimensional network
    corecore