36 research outputs found

    Acute kidney injury--forging ahead!

    Get PDF
    Detailed formal protocol with illustrations and extensive bibliography.UT Southwestern--Internal Medicin

    Canagliflozin and renal outcomes in type 2 diabetes and nephropathy

    Get PDF
    BACKGROUND Type 2 diabetes mellitus is the leading cause of kidney failure worldwide, but few effective long-term treatments are available. In cardiovascular trials of inhibitors of sodium–glucose cotransporter 2 (SGLT2), exploratory results have suggested that such drugs may improve renal outcomes in patients with type 2 diabetes. METHODS In this double-blind, randomized trial, we assigned patients with type 2 diabetes and albuminuric chronic kidney disease to receive canagliflozin, an oral SGLT2 inhibitor, at a dose of 100 mg daily or placebo. All the patients had an estimated glomerular filtration rate (GFR) of 30 to <90 ml per minute per 1.73 m2 of body-surface area and albuminuria (ratio of albumin [mg] to creatinine [g], >300 to 5000) and were treated with renin–angiotensin system blockade. The primary outcome was a composite of end-stage kidney disease (dialysis, transplantation, or a sustained estimated GFR of <15 ml per minute per 1.73 m2), a doubling of the serum creatinine level, or death from renal or cardiovascular causes. Prespecified secondary outcomes were tested hierarchically. RESULTS The trial was stopped early after a planned interim analysis on the recommendation of the data and safety monitoring committee. At that time, 4401 patients had undergone randomization, with a median follow-up of 2.62 years. The relative risk of the primary outcome was 30% lower in the canagliflozin group than in the placebo group, with event rates of 43.2 and 61.2 per 1000 patient-years, respectively (hazard ratio, 0.70; 95% confidence interval [CI], 0.59 to 0.82; P=0.00001). The relative risk of the renal-specific composite of end-stage kidney disease, a doubling of the creatinine level, or death from renal causes was lower by 34% (hazard ratio, 0.66; 95% CI, 0.53 to 0.81; P<0.001), and the relative risk of end-stage kidney disease was lower by 32% (hazard ratio, 0.68; 95% CI, 0.54 to 0.86; P=0.002). The canagliflozin group also had a lower risk of cardiovascular death, myocardial infarction, or stroke (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01) and hospitalization for heart failure (hazard ratio, 0.61; 95% CI, 0.47 to 0.80; P<0.001). There were no significant differences in rates of amputation or fracture. CONCLUSIONS In patients with type 2 diabetes and kidney disease, the risk of kidney failure and cardiovascular events was lower in the canagliflozin group than in the placebo group at a median follow-up of 2.62 years

    Cardiovascular outcomes in ESRD: can we do better

    No full text
    Detailed formal protocol with illustrations and extensive bibliography.UT Southwestern--Internal Medicin

    Calcifying vasculature: Does uremia add insult to injury?

    No full text
    Detailed formal protocol with illustrations and extensive bibliography.UT Southwestern--Internal Medicin

    A Multi-Center, Randomized, Controlled, Pivotal Study to Assess the Safety and Efficacy of a Selective Cytopheretic Device in Patients with Acute Kidney Injury.

    Get PDF
    Acute kidney injury (AKI) is a highly morbid condition in critically ill patients that is associated with high mortality. Previous clinical studies have demonstrated the safety and efficacy of the Selective Cytopheretic Device (SCD) in the treatment of AKI requiring continuous renal replacement therapy in the intensive care unit (ICU).A randomized, controlled trial of 134 ICU patients with AKI, 69 received continuous renal replacement therapy (CRRT) alone and 65 received SCD therapy.No significant difference in 60-day mortality was observed between the treated (27/69; 39%) and control patients (21/59; 36%, with six patients lost to follow up) in the intention to treat (ITT) analysis. Of the 19 SCD subjects (CRRT+SCD) and 31 control subjects (CRRT alone) who maintained a post-filter ionized calcium (iCa) level in the protocol's recommended range (≤ 0.4 mmol/L) for greater or equal to 90% of the therapy time, 60-day mortality was 16% (3/19) in the SCD group compared to 41% (11/27) in the CRRT alone group (p = 0.11). Dialysis dependency showed a borderline statistically significant difference between the SCD treated versus control CRRT alone patients maintained for ≥ 90% of the treatment in the protocol's recommended (r) iCa target range of ≤ 0.4 mmol/L with values of, 0% (0/16) and 25% (4/16), respectively (P = 0.10). When the riCa treated and control subgroups were compared for a composite index of 60 day mortality and dialysis dependency, the percentage of SCD treated subjects was 16% versus 58% in the control subjects (p<0.01). The incidence of serious adverse events did not differ between the treated (45/69; 65%) and control groups (40/65; 63%; p = 0·86).SCD therapy may improve mortality and reduce dialysis dependency in a tightly controlled regional hypocalcaemic environment in the perfusion circuit.ClinicalTrials.gov NCT01400893 http://clinicaltrials.gov/ct2/show/NCT01400893

    Spectral characteristics of urine specimens from healthy human volunteers analyzed using Raman chemometric urinalysis (Rametrix).

    No full text
    Raman chemometric urinalysis (Rametrix™) was used to analyze 235 urine specimens from healthy individuals. The purpose of this study was to establish the "range of normal" for Raman spectra of urine specimens from healthy individuals. Ultimately, spectra falling outside of this range will be correlated with kidney and urinary tract disease. Rametrix™ analysis includes direct comparisons of Raman spectra but also principal component analysis (PCA), discriminant analysis of principal components (DAPC) models, multivariate statistics, and it is available through GitHub as the Rametrix™ LITE Toolbox for MATLAB®. Results showed consistently overlapping Raman spectra of urine specimens with significantly larger variances in Raman shifts, found by PCA, corresponding to urea, creatinine, and glucose concentrations. A 2-way ANOVA test found that age of the urine specimen donor was statistically significant (p < 0.001) and donor sex (female or male identification) was less so (p = 0.0526). With DAPC models and blind leave-one-out build/test routines using the Rametrix™ PRO Toolbox (also available through GitHub), an accuracy of 71% (sensitivity = 72%; specificity = 70%) was obtained when predicting whether a urine specimen from a healthy unknown individual was from a female or male donor. Finally, from female and male donors (n = 4) who contributed first morning void urine specimens each day for 30 days, the co-occurrence of menstruation was found statistically insignificant to Rametrix™ results (p = 0.695). In addition, Rametrix™ PRO was able to link urine specimens with the individual donor with an average of 78% accuracy. Taken together, this study established the range of Raman spectra that could be expected when obtaining urine specimens from healthy individuals and analyzed by Rametrix™ and provides the methodology for linking results with donor characteristics

    Spectral characteristics of urine from patients with end-stage kidney disease analyzed using Raman Chemometric Urinalysis (Rametrix).

    No full text
    Raman Chemometric Urinalysis (RametrixTM) was used to discern differences in Raman spectra from (i) 362 urine specimens from patients receiving peritoneal dialysis (PD) therapy for end-stage kidney disease (ESKD), (ii) 395 spent dialysate specimens from those PD therapies, and (iii) 235 urine specimens from healthy human volunteers. RametrixTM analysis includes spectral processing (e.g., truncation, baselining, and vector normalization); principal component analysis (PCA); statistical analyses (ANOVA and pairwise comparisons); discriminant analysis of principal components (DAPC); and testing DAPC models using a leave-one-out build/test validation procedure. Results showed distinct and statistically significant differences between the three types of specimens mentioned above. Further, when introducing "unknown" specimens, RametrixTM was able to identify the type of specimen (as PD patient urine or spent dialysate) with better than 98% accuracy, sensitivity, and specificity. RametrixTM was able to identify "unknown" urine specimens as from PD patients or healthy human volunteers with better than 96% accuracy (with better than 97% sensitivity and 94% specificity). This demonstrates that an entire Raman spectrum of a urine or spent dialysate specimen can be used to determine its identity or the presence of ESKD by the donor

    Flow chart of the disposition in all of the patients (N = 134) enrolled.

    No full text
    <p>For the purpose of statistical analysis ITT is defined as all control and all treatment, whereas mITT is defined as all control and all treatment with iCa at recommended range >90% of the time.</p
    corecore