430 research outputs found

    Effects of flow separation and cove leakage on pressure and heat-transfer distributions along a wing-cove-elevon configuration at Mach 6.9

    Get PDF
    External and internal pressure and cold-wall heating-rate distributions were obtained in hypersonic flow on a full-scale heat-sink representation of the space shuttle orbiter wing-elevon-cove configuration in an effort to define effects of flow separation on cove aerothermal environment as a function of cove seal leak area, ramp angle, and free-stream unit Reynolds number. Average free-stream Mach number from all tests was 6.9; average total temperature from all tests was 3360 R; free-stream dynamic pressure ranged from about 2 to 9 psi; and wing angle of attack was 5 deg (flow compression). For transitional and turbulent flow separation, increasing cove leakage progressively increased heating rates in the cove. When ingested mass flow was sufficient to force large reductions in extent of separation, increasing cove leakage reduced heating rates in the cove to those for laminar attached flow. Cove heating-rate distributions calculated with a method that assumed laminar developing channel flow agreed with experimentally obtained distributions within root-mean-square differences that varied between 11 and 36 percent where cove walls were parallel for leak areas of 50 and 100 percent

    The lower main sequence of stars in the solar neighborhood: Model predictions versus observation

    Full text link
    We have used the Simbad database and VizieR catalogue access tools to construct the observational color-absolute magnitude diagrams of nearby K-M dwarfs with precise Hipparcos parallaxes (\sigma_\pi/\pi < 0.05). Particular attention has been paid to removing unresolved double/multiple and variable stars. In addition to archival data, we have made use of nearly 2000 new radial-velocity measurements of K-M dwarfs to identify spectroscopic binary candidates. The main sequences, cleaned from unresolved binaries, variable stars, and old population stars which can also widen the sequence due to their presumably lower metallicity, were compared to available solar-metallicity models. Significant ofsets of most of the model main-sequence lines are seen with respect to observational data, especially for the lower-mass stars. Only the location and slope of the Victoria-Regina and, partly, BaSTI isochrones match the data quite well.Comment: Submitted to JENAM-2011 SpS3 (Saint Petersburg, July 4-8, 2011) Proceeding

    Pressure and heat-transfer distributions in a simulated wing-elevon cove with variable leakage at a free-stream Mach number of 6.9

    Get PDF
    An experimental aerodynamic heating investigation was conducted to determine effects of hot boundary-layer ingestion into the cove on the windward surface between a wing and elevon for cove seal leak areas nominally between 0 and 100 percent of cove entrance area. Pressure and heating-rate distributions were obtained on the wing and elevon surfaces and on the cove walls of a full-scale model that represented a section of the cove region on the space shuttle orbiter. Data were obtained for both attached and separated turbulent boundary layers upstream of the unswept cove entrance. Average free-stream Mach number was 6.9, average free-stream unit Reynolds numbers were 1.31 x 10 to the 6th power and 4.40 x 10 to the 6th power per meter (0.40 x 10 to the 6th power and 1.34 x 10 to the 6th power per foot), and average total temperature was 1888 K (3400 R). Cove pressures and heating rates varied as a function of seal leak area independent of leak aspect ratio. Although cove heating rates for attached flow did not appear intolerable, it was postulated that convective heating in the cove may increase with time. For separated flow, the cove environment was considered too severe for unprotected interior structures of control surfaces

    Loading and heating of a large flat plate at Mach 7 in the Langley 8-foot high-temperature structures tunnel

    Get PDF
    Surface pressure and cold-wall heating rate distributions (wall-temperature to total-temperature ratio approximately 0.2) were obtained on a large, flat calibration panel at a nominal Mach number of 7 in an 8-foot high-temperature structures tunnel. Panel dimensions were 42.5 by 60.0 in. Test objectives were: (1) to map available flat-plate loading and heating provided by the facility and (2) to determine effectiveness of leading-edge bluntness, boundary-layer trips, and aerodynamic fences in generating a uniform, streamwise turbulent flow field over the test surface of a flat-sided panel holder

    Effects of configuration modifications on aerodynamic characteristics of tension shell shapes at Mach 3.0

    Get PDF
    Configuration modifications of tension shell shapes to improve aerodynamic characteristics at Mach 3 by delaying onset of flow separatio

    Techniques for aerothermal tests of large, flightweight thermal protection panels in a Mach 7 wind tunnel

    Get PDF
    Thermal performance and structural integrity are experimentally evaluated in the Langley 8-ft high temperature structures tunnel, which uses a combustion products test medium to provide realistic combinations of aerodynamic heating and loading. Recently developed techniques provide independent control of rate and magnitude of surface heating and differential pressure, protection against adverse acoustics buffeting during facility starting and stopping, programed radiant heating before exposing test panels to the high energy stream, and infrared radiometry for detailed surface temperatures. These techniques were verified repeatedly by return of useful data on metallic and nonmetallic panel concepts of reusable surface insulation
    corecore