105 research outputs found
Performance evaluation of nursing homes using finite mixtures of logistic models and M-quantile regression for binary data
Structural MRI outcomes and predictors of disease progression in amyotrophic lateral sclerosis
Background and aims: Considering the great heterogeneity of amyotrophic lateral sclerosis (ALS), the identification of accurate prognostic predictors is fundamental for both the clinical practice and the design of treatment trials. This study aimed to explore the progression of clinical and structural brain changes in patients with ALS, and to assess magnetic resonance imaging (MRI) measures of brain damage as predictors of subsequent functional decline. Methods: 50 ALS patients underwent clinical evaluations and 3 T MRI scans at regular intervals for a maximum of 2 years (total MRI scans = 164). MRI measures of cortical thickness, as well as diffusion tensor (DT) metrics of microstructural damage along white matter (WM) tracts were obtained. Voxel-wise regression models and longitudinal mixed-effects models were used to test the relationship between clinical decline and baseline and longitudinal MRI features. Results: The rate of decline of the ALS Functional Rating Scale revised (ALSFRS-r) was significantly associated with the rate of fractional anisotropy (FA) decrease in the body of the corpus callosum (CC). Corticospinal tract (CST) and CC-body alterations had a faster progression in patients with higher baseline ALSFRS-r scores and greater CC-body disruption at baseline. Lower FA of the cerebral peduncle was associated with faster subsequent clinical progression. Conclusions: In this longitudinal study, we identified a significant association between measures of WM damage of the motor tracts and functional decline in ALS patients. Our data suggest that a multiparametric approach including DT MRI measures of brain damage would provide an optimal method for an accurate stratification of ALS patients into prognostic classes
Transcranial static magnetic stimulation for amyotrophic lateral sclerosis: a bicentric, randomised, double-blind placebo-controlled phase 2 trial
Background: Enhanced glutamatergic transmission leading to motor neuron death is considered the major pathophysiological mechanism of amyotrophic lateral sclerosis (ALS). Motor cortex excitability can be suppressed by transcranial static magnetic stimulation (tSMS), thus tSMS can be evaluated as a potential treatment for ALS. The aim of present study was to investigate the efficacy and safety of tSMS in ALS. Methods: In this phase 2 trial, we randomly assigned ALS patients to receive daily tSMS or placebo stimulation over a period of 6 months. For each participant we calculated mean disease monthly progression rate (MPR) as the variation of the total ALS Functional Rating Scale-Revised (ALSRFS-R) score, before the beginning of the treatment (over a period of at least three months) and over the six-month treatment period. The primary efficacy outcome was the difference in MPR before and after the beginning of treatment. Secondary outcomes included safety and tolerability, compliance, and changes in corticospinal output. A long-term follow-up of 18 months was performed in all patients who completed the six-month treatment considering a composite endpoint event (tracheostomy or death). Trial registered at ClinicalTrials.gov, ID: NCT04393467, status: closed. Findings: Forty participants were randomly assigned to real (n = 21) or placebo stimulation (n = 19). Thirty-two participants (18 real and 14 placebo) completed the 6-month treatment. The MPR did not show statistically significant differences between the two arms during the pre-treatment (mean ± Standard deviation; Real: 1.02 ± 0.62, Sham: 1.02 ± 0.57, p-value = 1.00) and treatment period (Real: 0.90 ± 0.55, Sham: 0.94 ± 0.55, p-value = 0.83). Results for secondary clinical endpoints showed that the treatment is feasible and safe, being compliance with tSMS high. The change in corticospinal output did not differ significantly between the two groups. At the end of the long-term follow-up of 18 months, patients of real group had a statistically significant higher tracheostomy-free survival compared with patients of placebo group (Hazard Ratio = 0.27 95% Confidence interval 0.09–0.80, p-value = 0.019). Interpretation: tSMS did not modify disease progression during the 6 months of treatment. However, long-term follow-up revealed a substantial increase in tracheostomy free survival in patients treated with real stimulation supporting the evaluation of tSMS in larger and more prolonged studies. Funding: The “ Fondazione ‘Nicola Irti’ per le opere di carità e di cultura”, Rome, Italy, supported present study
The contact angle of nanofluids as thermophysical property
Droplet volume and temperature affect contact angle significantly. Phase change heat transfer processes of nanofluids – suspensions containing nanometre-sized particles – can only be modelled properly by understanding these effects. The approach proposed here considers the limiting contact angle of a droplet asymptotically approaching zero-volume as a thermophysical property to characterise nanofluids positioned on a certain substrate under a certain atmosphere.
Graphene oxide, alumina, and gold nanoparticles are suspended in deionised water. Within the framework of a round robin test carried out by nine independent European institutes the contact angle of these suspensions on a stainless steel solid substrate is measured with high accuracy. No dependence of nanofluids contact angle of sessile droplets on the measurement device is found. However, the measurements reveal clear differences of the contact angle of nanofluids compared to the pure base fluid.
Physically founded correlations of the contact angle in dependency of droplet temperature and volume are obtained from the data. Extrapolating these functions to zero droplet volume delivers the searched limiting contact angle depending only on the temperature. It is for the first time, that this specific parameter, is understood as a characteristic material property of nanofluid droplets placed on a certain substrate under a certain atmosphere. Together with the surface tension it provides the foundation of proper modelling phase change heat transfer processes of nanofluids
Reliable change indices for the Italian version of the Montreal Cognitive Assessment (MoCA) in non-demented Parkinson’s disease patients
Background:. The present study aimed at deriving regression-based reliable change indices (RCIs) for the Montreal Cognitive Assessment (MoCA) in an Italian cohort of non-demented Parkinson’s disease (PD) patients. Methods: N = 33 consecutive, non-demented PD patients were followed-up at a 5-to-8-month interval (M = 6.6; SD = 0.6) with the MoCA. Practice effects and test-retest reliability were assessed via dependent-sample t-tests and intra-class correlation (ICC) coefficients, respectively. RCIs were derived separately for raw and demographically adjusted MoCA scores according to a standardized regression-based approach by accounting for both baseline confounders (i.e., demographics, disease duration and Unified Parkinson’s Disease Rating Scale scores) and retest interval. Results: No practice effects were found (t(32) = 0.29; p =.778), with acceptable test-retest reliability being detected (ICC = 0.67). MoCA scores at T0 proved to be the only significant predictor of T1 MoCA performances within both the model addressing raw scores and that addressing adjusted scores (ps < 0.001). Conclusions: The present study provides Italian practitioners and researchers with regression-based RCIs for the MoCA in non-demented PD patients, which can be reliably adopted for retest interval ≥ 5 and ≤ 8 months without encountering any practice effect
Genetics and human rights: Two histories: restoring genetic identity after forced disappearance and identity suppression in Argentina and after compulsory isolation for leprosy in Brazil
Ranking Nursing Homes’ Performances Through a Latent Markov Model with Fixed and Random Effects
- …
