793 research outputs found

    First observation of a narrow charm-strange meson DsJ(2632) -> Ds eta and D0 K+

    Full text link
    We report the first observation of a charm-strange meson DsJ(2632) at a mass of 2632.6+/-1.6 MeV/c^2 in data from SELEX, the charm hadro-production experiment E781 at Fermilab. This state is seen in two decay modes, Ds eta and D0 K+. In the Ds eta decay mode we observe an excess of 49.3 events with a significance of 7.2sigma at a mass of 2635.9+/-2.9 MeV/c^2. There is a corresponding peak of 14 events with a significance of 5.3sigma at 2631.5+/-1.9 MeV/c^2 in the decay mode D0 K+. The decay width of this state is <17 MeV/c^2 at 90% confidence level. The relative branching ratio Gamma(D0K+)/Gamma(Dseta) is 0.16+/-0.06. The mechanism which keeps this state narrow is unclear. Its decay pattern is also unusual, being dominated by the Ds eta decay mode.Comment: 5 pages, 3 included eps figures. v2 as accepted for publication by PR

    First Observation of the Doubly Charmed Baryon Xi_cc^+

    Full text link
    We observe a signal for the doubly charmed baryon Xi_cc^+ in the charged decay mode Xi_cc^+ --> Lambda_c^+ K- pi+ in data from SELEX, the charm hadro-production experiment at Fermilab. We observe an excess of 15.9 events over an expected background of 6.1 +/- 0.5 events, a statistical significance of 6.3sigma. The observed mass of this state is (3519 +/- 1) MeV/c^2. The Gaussian mass width of this state is 3MeV/c^2, consistent with resolution; its lifetime is less than 33fsec at 90% confidence.Comment: 5 pages, 3 figures, accepted for publication in Physical Review Letter

    Observation of the Cabibbo-suppressed decay Xi_c+ -> p K- pi+

    Full text link
    We report the first observation of the Cabibbo-suppressed charm baryon decay Xi_c+ -> p K- pi+. We observe 150 +- 22 events for the signal. The data were accumulated using the SELEX spectrometer during the 1996-1997 fixed target run at Fermilab, chiefly from a 600 GeV/c Sigma- beam. The branching fractions of the decay relative to the Cabibbo-favored Xi_c+ -> Sigma+ K- pi+ and Xi_c+ -> X- pi+ pi+ are measured to be B(Xi_c+ -> p K- pi+)/B(Xi_c+ -> Sigma+ K- pi+) = 0.22 +- 0.06 +- 0.03 and B(Xi_c+ -> p K- pi+)/B(Xi_c+ -> X- pi+ pi+) = 0.20 +- 0.04 +- 0.02, respectively.Comment: 5 pages, RevTeX, 3 figures (postscript), Submitted to Phys. Rev. Let

    Measurement of the Ds lifetime

    Get PDF
    We report precise measurement of the Ds meson lifetime. The data were taken by the SELEX experiment (E781) spectrometer using 600 GeV/c Sigma-, pi- and p beams. The measurement has been done using 918 reconstructed Ds. The lifetime of the Ds is measured to be 472.5 +- 17.2 +- 6.6 fs, using K*(892)0K+- and phi pi+- decay modes. The lifetime ratio of Ds to D0 is 1.145+-0.049.Comment: 5 pages, 2 figures submitted to Phys. Lett.

    Confirmation of the Double Charm Baryon Xi_cc+ via its Decay to p D+ K-

    Get PDF
    We observes a signal for the double charm baryon Xi_cc+ in the charged decay mode Xi_cc+ -> p D+ K- to complement the previously reported decay Xi_cc+ -> Lambda_c K- pi+ in data from SELEX, the charm hadro-production experiment (E781) at Fermilab. In this new decay mode we observe an excess of 5.62 events over an expected background estimated by event mixing to be 1.38+/-0.13 events. The Poisson probability that a background fluctuation can produce the apparent signal is less than 6.4E-4. The observed mass of this state is (3518+/-3)MeV/c^2, consistent with the published result. Averaging the two results gives a mass of (3518.7+/-1.7)MeV/c^2. The observation of this new weak decay mode confirms the previous SELEX suggestion that this state is a double charm baryon. The relative branching ratio Gamma(Xi_cc+ -> pD+K-)/Gamma(Xi_cc+ -> Lambda_c K- pi+) = 0.36+/-0.21.Comment: 11 pages, 6 included eps figures. v2 includes improved statistical method to determine significance of observation. Submitted to PL

    First Measurement of pi e -> pi e gamma Pion Virtual Compton Scattering

    Full text link
    Pion Virtual Compton Scattering (VCS) via the reaction pi e --> pi e gamma was observed in the Fermilab E781 SELEX experiment. SELEX used a 600 GeV/c pi- beam incident on target atomic electrons, detecting the incident pi- and the final state pi-, electron and gamma. Theoretical predictions based on chiral perturbation theory are incorporated into a Monte Carlo simulation of the experiment and are compared to the data. The number of reconstructed events (9) and their distribution with respect to the kinematic variables (for the kinematic region studied) are in reasonable accord with the predictions. The corresponding pi- VCS experimental cross section is sigma=38.8+-13 nb, in agreement with the theoretical expectation sigma=34.7 nb.Comment: 10 pages, 12 figures, 4 tables, 25 references, SELEX home page is http://fn781a.fnal.gov/, revised July 21, 2002 in response to journal referee Comment

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented
    corecore