106 research outputs found
Isospin transport in 84Kr + 112,124Sn collisions at Fermi energies
Isotopically resolved fragments with Z<=20 have been studied with high
resolution telescopes in a test run for the FAZIA collaboration. The fragments
were produced by the collision of a 84Kr beam at 35 MeV/nucleon with a n-rich
(124Sn) and a n-poor (112Sn) target. The fragments, detected close to the
grazing angle, are mainly emitted from the phase-space region of the
projectile. The fragment isotopic content clearly depends on the n-richness of
the target and it is a direct evidence of isospin diffusion between projectile
and target. The observed enhanced neutron richness of light fragments emitted
from the phase-space region close to the center of mass of the system can be
interpreted as an effect of isospin drift in the diluted neck region.Comment: 8 pages, 7 figure
The new ALEPH Silicon Vertex Detector
The ALEPH collaboration, in view of the importance of effective vertex detection for the Higgs boson search at LEP 2, decided to upgrade the previous vertex detector. Main changes were an increased length (±20 cm), a higher granularity for rφ view (50 µm), a new preamplifier (MX7 rad hard chip), a polymide (upilex) fan-out on z side to carry the signals from the strips to the front-end electronics outside the fiducial region reducing consequently the passive material in the central region by a factor of two. The detector, the running experience and its performance will be described
Rhodococcus equi Pneumonia in Kidney Transplant Recipient Affected by Acute Intermittent Porphyria: A Case Report
Rhodococcus equi is a gram-positive coccobacillus responsible for severe infections in patients with weakened immune systems. R equi generally causes pnumonia that may evolve into fatal systemic infection if left untreated. Here, we present a case of a 67-year-old woman affected by acute intermittent porphyria (AIP) who developed R equi pneumonia 7 months after kidney transplant. Although clinical features at presentation were nonspecific, lung computed tomography showed right perihilar consolidation with a mass-like appearance causing bronchial obstruction. Appropriate antibiotic including intravenous meropenem and oral azithromycin that was then switched to oral levofloxacin and oral azithromycin along with reduction of immunosuppressive therapy resolved pneumonia without provoking an acute attack of porphyria. AIP limited the choice of antibiotics for the treatment of R equi infection because some potentially porphyrinogenic antibacterial agents were avoided. Based on this experience, azithromycin and meropenem can be safely administered for the treatment of R Equi infection in patients with AIP
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to neq/cm. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations
CMS physics technical design report : Addendum on high density QCD with heavy ions
Peer reviewe
Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade
The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment's silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to Phi(eq) = 2x10(16) cm(-2), and an ionising dose of approximate to 5 MGy after an integrated luminosity of 3000 fb(-1). Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 mu m thick p-bulk pad diodes and strip sensors irradiated up to fluences of Phi(eq) = 1.3 x 10(16) cm(-2) are shown.Peer reviewe
The CMS Phase-1 pixel detector upgrade
The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.Peer reviewe
- …
