12 research outputs found

    Elemental hydrochemistry assessment on its variation and quality status in Langat River, Western Peninsular Malaysia.

    Get PDF
    This paper discusses the hydrochemistry variation and its quality status in Langat River, based on the chemistry of major ions, metal concentrations and suitability for drinking purposes. Water samples were collected from 30 different stations to assess their hydrochemical characteristics. The physico-chemical parameters selected were temperature, electrical conductivity, total dissolved solids (TDS), salinity, dissolved oxygen , pH, redox potential, HCO3, Cl, SO4, NO3, Ca, Na, K, Mg, 27Al, 138Ba, 9Be, 111Cd, 59Co, 63Cu, 52Cr, 57Fe, 55Mn, 60Ni, 208Pb, 80Se and 66Zn to investigate the variation of the constituents in the river water. Most of the parameters comply with the Drinking Water Quality Standard of the World Health Organization and the Malaysian National Standard for Drinking Water Quality by the Malaysia Ministry of Health except for EC, TDS, Cl, HCO3, SO4, Na, Mg, Al, Fe and Se. The results show that the Langat River is unsuitable for drinking purposes directly without treatment

    Shoot chloride exclusion and salt tolerance in grapevine is associated with differential ion transporter expression in roots

    Get PDF
    BACKGROUND: Salt tolerance in grapevine is associated with chloride (Cl-) exclusion from shoots; the rate-limiting step being the passage of Cl- between the root symplast and xylem apoplast. Despite an understanding of the physiological mechanism of Cl- exclusion in grapevine, the molecular identity of membrane proteins that control this process have remained elusive. To elucidate candidate genes likely to control Cl- exclusion, we compared the root transcriptomes of three Vitis spp. with contrasting shoot Cl- exclusion capacities using a custom microarray. RESULTS: When challenged with 50 mM Cl-, transcriptional changes of genotypes 140 Ruggeri (shoot Cl- excluding rootstock), K51-40 (shoot Cl- including rootstock) and Cabernet Sauvignon (intermediate shoot Cl- excluder) differed. The magnitude of salt-induced transcriptional changes in roots correlated with the amount of Cl- accumulated in shoots. Abiotic-stress responsive transcripts (e.g. heat shock proteins) were induced in 140 Ruggeri, respiratory transcripts were repressed in Cabernet Sauvignon, and the expression of hypersensitive response and ROS scavenging transcripts was altered in K51-40. Despite these differences, no obvious Cl- transporters were identified. However, under control conditions where differences in shoot Cl- exclusion between rootstocks were still significant, genes encoding putative ion channels SLAH3, ALMT1 and putative kinases SnRK2.6 and CPKs were differentially expressed between rootstocks, as were members of the NRT1 (NAXT1 and NRT1.4), and CLC families. CONCLUSIONS: These results suggest that transcriptional events contributing to the Cl- exclusion mechanism in grapevine are not stress-inducible, but constitutively different between contrasting varieties. We have identified individual genes from large families known to have members with roles in anion transport in other plants, as likely candidates for controlling anion homeostasis and Cl- exclusion in Vitis species. We propose these genes as priority candidates for functional characterisation to determine their role in chloride transport in grapevine and other plants.Sam W Henderson, Ute Baumann, Deidre H Blackmore, Amanda R Walker, Rob R Walker and Matthew Gilliha

    How safe is diathermy in patients with cochlear implant?

    No full text
    INTRODUCTION: Cochlear implants are surgically inserted electrical devices that enable severely or profoundly deaf individuals to interpret sounds from their environment and communicate more effectively. As a result of their electrical nature, they are susceptible to electromagnetic interference and can be damaged by excessive electrical energy. Surgical diathermy is one source of such potentially damaging energy. The British Cochlear Implant Group guidelines advise that monopolar diathermy should not be used in the head and neck region in patients with cochlear implants and that bipolar diathermy should not be used within 2cm of the implant (http://www.bcig.org.uk/site/public/current/safety.htm).METHODS: A questionnaire was provided to 36 surgeons working in different specialties in the head and neck region, inquiring as to their knowledge of the safety considerations when using diathermy in cochlear implant patients. Thirty-five surgeons provided responses.RESULTS: Overall, 77% of the respondents were unaware of the existence of published guidelines. Even when given an option to seek advice, 11% erroneously felt it was safe to use monopolar diathermy above the clavicles with a cochlear implant in situ and 49% felt that there was no restriction on the use of bipolar diathermy.CONCLUSIONS: There is a significant deficit in the knowledge of safe operating practice in the rapidly expanding population of patients with cochlear implants which threatens patient safety. Through this publication we aim to increase awareness of these guidelines among members of the surgical community and this paper is intended to act as a point of reference to link through to the published safety guidelines

    Poster Session 2The imaging examination and quality assessmentP520Benefit of early basic transthoracic echocardiography (TTE) in emergency patients performed by physicians with low to intermediate TTE experienceP521Appropriateness criteria in echocardiography. A contemporary necessity in clinical practiceP522Interobserver variability in 2d transthoracic echocardiography impact of scanning and reading on total variability results from the STAAB cohort study quality controlP5233D printing for personalised planning of catheter-based left atrial appendage occlusionP524Central obesity: an independent role or synergistic effect to metabolic syndrome on right atrial structure?P525Dynamics of left ventricular volumes and mortality in patients with early and late effect of cardiac resynchronization therapyP526Variability of thoracic aortic diameters according to gender, age and body surface area. Time to forget absolute cut-off values?P527The association of left ventricular outflow tract velocity time integral to all-cause mortality in elderly patients with heart failureP528Left ventricular myocardial performance and atrioventricular coupling in patients with primary arterial hypertensionP529Interest of a combinatory approach based on traditional left ventricular dyssynchrony parameters and cardiac work estimated by pressure-strain loop curves for the prediction of cardiac resynchronizatP530The evaluation of cardiac performance by pressure-strain loops: a useful tool for the identification of cardiac resynchronization therapy respondersP531Left ventricle cardiac function by 2D-speckle tracking echocardiography in diabetes mellitus population: sub-clinical systolic disfunction studyP532Biphasic tissue doppler mitral annular isovolumic contraction velocities are associated with left ventricular function, isovolumic relaxation, and pulmonary wedge pressure in heart failure patientsP533Abnormal left atrial volumes and strains are associated with increased arterial stiffnes in patients with cryptogenic stroke: a novel pathophysiological pathP534Detection of coronary microvascular disease using two-dimensional speckle-tracking echocardiographyP535Predictive value of a bi-dimensional transthoracic echocardiographic sign of " binary image" to identify the anomalous origin of the left circumflex coronary artery from the right coronary sinusP536Systematic review and meta-analysis of screening for coronary artery disease in asymptomatic diabetic patientsP537Noninvasive screening test for diagnosis of nonobstructive coronary artery disease using echocardiographic criteriaP538Early echocardiography after primary angioplasty, important role in predicting left ventricular remodelingP539Prognostic impact of low-flow severe aortic stenosis in Japanese patients undergoing transcatheter aortic valve implantation: the ocean-tavi registryP540Left ventricular outflow tract geometry and its impact on aortic valve area calculations in aortic stenosis using 3D transoesophageal echocardiography and 2D transthoracic echocardiographyP541Impaired left atrial myocardial deformation predicts postoperative atrial fibrillation after aortic valve replacement in patients with aortic stenosisP542Ejection fraction-velocity ratio in predicting symptoms in severe aortic stenosisP543Incremental value of transesophageal echocardiography in conjunction with transthoracic echocardiography in the assessment of aortic stenosis severity

    Full text link
    corecore