188 research outputs found

    Expression of CD80 and CD86 on T lymphocytes and monocytes of asthmatic children

    Get PDF
    Background: For T lymphocytes to get optimally activated, they need costimulatory signals that can be provided efficiently by costimulatory molecules CD80 and CD86Objective: This study was done to assess the expression of costimulatory molecules CD80 and CD86 on T lymphocytes and monocytes of asthmatic children. The effect of clinical grading of asthma and intake of inhaled steroids on the level of their expression was assessed.Methods: The study included 44 asthmatics (12 with acute asthma and 32 in between attacks) and 12 controls. The asthmatic children were classified according to clinical severity into mild (15 cases), moderate (9 cases) and severe (8 cases). Flow cytometry was performed to analyze the expression of CD80 and CD86 on blood T lymphocytes and monocytesResults: The percentage of expression of costimulatory molecules CD80 and CD86 on T lymphocytes and monocytes were statistically higher in asthmatic children whether in acute or in between attacks compared to the control group (p<0.05). This up regulation suggests their critical role in pathogenesis of bronchial allergic inflammation in asthma. The percentage of expression of CD80 and CD86 on monocytes were significantly higher in asthmatics during their acute exacerbations compared to those in between attacks (p<0.05). Comparing the clinical subgroups of asthma, there was no statistically significant difference between mild and moderate asthmatics as regards level of co-expression (p > 0.05); however the difference was statistically significant between mild and severe cases (p <0.05).  Asthmatics on inhaled steroids showed significant lower percentage of CD80 and CD86 expression on T lymphocytes and monocytes.Conclusion: The enhanced expression of both CD80 and CD86 on antigenpresenting cells and T lymphocytes in bronchial asthma is probably  involved in the establishment and maintenance of chronic inflammation of the airways.Key words: Asthma, T lymphocytes, Costimulation, CD80 and CD86

    Spontaneous cervical epidural haematoma: role of antiplatelets

    Get PDF
    Cervical epidural haematomas should be considered in any patient presenting with neck pain and suspected stroke particularly if taking antiplatelets

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Reliability of self-reported health risk factors and chronic conditions questions collected using the telephone in South Australia, Australia

    Get PDF
    Extent: 10p.Background: Accurate monitoring of health conditions and behaviours, and health service usage in the population, using an effective and economical method is important for planning and evaluation. This study examines the reliability of questions asked in a telephone survey by conducting a test/retest analysis of a range of questions covering demographic variables, health risk factors and self-reported chronic conditions among people aged 16 years and over. Methods: A Computer Assisted Telephone Interviewing (CATI) survey on health issues of South Australians was re-administered to a random sub-sample of 154 respondents between 13-35 days (mean 17) after the original survey. Reliability between questions was assessed using Cohen’s kappa and intraclass correlation coefficients. Results: Demographic questions (age, gender, number of adults and children in the household, country of birth) showed extremely high reliability (0.97 to 1.00). Health service use (ICC = 0.90 95% CI 0.86-0.93) and overall health status (Kappa = 0.60 95% CI 0.46-0.75) displayed moderate agreement. Questions relating to self-reported risk factors such as smoking (Kappa = 0.81 95% CI 0.72-0.89) and alcohol drinking (ICC 0.75 = 95% CI 0.63-0.83) behaviour showed good to excellent agreement, while questions relating to self-reported risk factors such as time spent walking for physical activity (ICC 0.47 = 95% CI 0.27-0.61), fruit (Kappaw = 0.60 95% CI 0.45-0.76) and vegetable consumption (Kappaw = 0.50 95% CI 0.32-0.69) showed only moderate agreement. Self-reported chronic conditions displayed substantial to almost perfect agreement (0.72 to 1.00) with the exception of moderate agreement for heart disease (Kappa = 0.82 95% CI 0.57-0.99). Conclusion: These results show the questions assessed to be reliable in South Australia for estimating health conditions and monitoring health related behaviours using a CATI survey.Eleonora Dal Grande, Simon Fullerton and Anne W Taylo

    GW190814: Gravitational Waves from the Coalescence of a 23 Solar Mass Black Hole with a 2.6 Solar Mass Compact Object

    Get PDF
    We report the observation of a compact binary coalescence involving a 22.2–24.3 M⊙ black hole and a compact object with a mass of 2.50–2.67 M⊙ (all measurements quoted at the 90% credible level). The gravitational-wave signal, GW190814, was observed during LIGO's and Virgo's third observing run on 2019 August 14 at 21:10:39 UTC and has a signal-to-noise ratio of 25 in the three-detector network. The source was localized to 18.5 deg2 at a distance of Mpc; no electromagnetic counterpart has been confirmed to date. The source has the most unequal mass ratio yet measured with gravitational waves, , and its secondary component is either the lightest black hole or the heaviest neutron star ever discovered in a double compact-object system. The dimensionless spin of the primary black hole is tightly constrained to ≤0.07. Tests of general relativity reveal no measurable deviations from the theory, and its prediction of higher-multipole emission is confirmed at high confidence. We estimate a merger rate density of 1–23 Gpc−3 yr−1 for the new class of binary coalescence sources that GW190814 represents. Astrophysical models predict that binaries with mass ratios similar to this event can form through several channels, but are unlikely to have formed in globular clusters. However, the combination of mass ratio, component masses, and the inferred merger rate for this event challenges all current models of the formation and mass distribution of compact-object binaries

    Search for Ultra-high-energy Photons from Gravitational Wave Sources with the Pierre Auger Observatory

    Get PDF
    A search for time-directional coincidences of ultra-high-energy (UHE) photons above 10 EeV with gravitational wave (GW) events from the LIGO/Virgo runs O1 to O3 is conducted with the Pierre Auger Observatory. Due to the distinctive properties of photon interactions and to the background expected from hadronic showers, a subset of the most interesting GW events is selected based on their localization quality and distance. Time periods of 1000 s around and 1 day after the GW events are analyzed. No coincidences are observed. Upper limits on the UHE photon fluence from a GW event are derived that are typically at & SIM;7 MeV cm(-2) (time period 1000 s) and & SIM;35 MeV cm(-2) (time period 1 day). Due to the proximity of the binary neutron star merger GW170817, the energy of the source transferred into UHE photons above 40 EeV is constrained to be less than 20% of its total GW energy. These are the first limits on UHE photons from GW sources

    Erratum: "Searches for Gravitational Waves from Known Pulsars at Two Harmonics in 2015–2017 LIGO Data" (2019, ApJ, 879, 10)

    Get PDF
    This is a correction for 2019 ApJ 879 1

    Search for gravitational waves from Scorpius X-1 in the second Advanced LIGO observing run with an improved hidden Markov model

    Get PDF
    We present results from a semicoherent search for continuous gravitational waves from the low-mass x-ray binary Scorpius X-1, using a hidden Markov model (HMM) to track spin wandering. This search improves on previous HMM-based searches of LIGO data by using an improved frequency domain matched filter, the J-statistic, and by analyzing data from Advanced LIGO’s second observing run. In the frequency range searched, from 60 to 650 Hz, we find no evidence of gravitational radiation. At 194.6 Hz, the most sensitive search frequency, we report an upper limit on gravitational wave strain (at 95% confidence) of h95%0=3.47×10−25 when marginalizing over source inclination angle. This is the most sensitive search for Scorpius X-1, to date, that is specifically designed to be robust in the presence of spin wandering
    corecore