1,677 research outputs found
Infiltration into inclined fibrous sheets
The flow from line and point sources through an inclined fibrous sheet is studied experimentally and theoretically for wicking from a saturated region and flow from a constant-flux source. Wicking from a saturated line generates a wetted region whose length grows diffusively, linearly or tends to a constant, depending on whether the sheet is horizontal or inclined downwards or upwards. A constant-flux line source generates a wetted region which ultimately grows linearly with time, and is characterized by a capillary fringe whose thickness depends on the relative strength of the source, gravitational and capillary forces. Good quantitative agreement is observed between experiments and similarity solutions.Capillary-driven and constant-flux source flows issuing from a point on a horizontal sheet generate a wetted patch whose radius grows diffusively in time. The flow is characterized by the relative strength of the source and spreading induced by the action of capillary forces, gamma. As gamma increases, the fraction of the wetted region which is saturated increases. Wicking from a saturated point corresponds to gamma = gamma(c), and spreads at a slower rate than from a line source. For gamma < gamma(c), the flow is partially saturated everywhere. Good agreement is observed between measured moisture profiles, rates of spreading, and similarity solutions.Numerical solutions are developed for point sources on inclined sheets. The moisture profile is characterized by a steady region circumscribed by a narrow boundary layer across which the moisture content rapidly changes. An approximate analytical solution describes the increase in the size of the wetted region with time and source strength; these conclusions are confirmed by numerical calculations. Experimental measurements of the downslope length are observed to be slightly in excess of theoretical predictions, though the dependence on time, inclination and flow rate obtained theoretically is confirmed. Experimental measurements of cross-slope width are in agreement with numerical results and solutions for short and long times. The affect of a percolation threshold is observed to ultimately arrest cross-slope transport, placing a limitation on the long-time analysis
Quantitative LEED I-V and ab initio study of the Si(111)-3x2-Sm surface structure and the missing half order spots in the 3x1 diffraction pattern
We have used Low Energy Electron Diffraction (LEED) I-V analysis and ab
initio calculations to quantitatively determine the honeycomb chain model
structure for the Si(111)-3x2-Sm surface. This structure and a similar 3x1
recontruction have been observed for many Alkali-Earth and Rare-Earth metals on
the Si(111) surface. Our ab initio calculations show that there are two almost
degenerate sites for the Sm atom in the unit cell and the LEED I-V analysis
reveals that an admixture of the two in a ratio that slightly favours the site
with the lower energy is the best match to experiment. We show that the I-V
curves are insensitive to the presence of the Sm atom and that this results in
a very low intensity for the half order spots which might explain the
appearance of a 3x1 LEED pattern produced by all of the structures with a 3x2
unit cell.Comment: 10 pages, 13 figures. Preliminary work presented at the the APS March
meeting, Baltimore MD, 2006. To be published in Phys. Rev. B. April/May 200
The implications of transporting architecture on human health
This is the author accepted manuscript.Where modern buildings are unable to maintain the internal environment to within comfort levels they often rely on mechanical systems to become habitable. This could be due to bad design or putting the building in an environment for which it is not suited. Due to climate change it is likely that all buildings will in effect and time be moved to an environment for which it is not suited. In this work the effects of changes in climate on the internal environment will be explored and an index to define how moveable a construction might be, will be developed.The authors would like to thank the EPSRC for their support [grant ref: EP/J002380/1
A comparison between Gaussian Process emulation and Genetic Algorithms for optimising energy use of buildings
Computing speed has increased greatly over recent years. Building designers can now simulate complex building models in a short time. However, even with short simulation times, building optimisation routines can still take too long for some applications. In this paper, we compare how well genetic algorithms (GAs) and Gaussian process emulation with sequential optimisation (GPESO) optimise a building to minimise the energy use. The GA approach performs a GA routine on an EnergyPlus model and the GPESO technique creates a Gaussian Process emulator (GPE) also based on the EnergyPlus model. The GPESO uses an expected improvement algorithm to sequentially improve the GPE. The results show that the GPESO technique outperforms the GA in terms of minimising the number of simulations required and the solution obtained.This work was supported by the Engineering and Physical Sciences Research Council [EPSRC grant
number EP/J002380/1]
STM and ab initio study of holmium nanowires on a Ge(111) Surface
A nanorod structure has been observed on the Ho/Ge(111) surface using
scanning tunneling microscopy (STM). The rods do not require patterning of the
surface or defects such as step edges in order to grow as is the case for
nanorods on Si(111). At low holmium coverage the nanorods exist as isolated
nanostructures while at high coverage they form a periodic 5x1 structure. We
propose a structural model for the 5x1 unit cell and show using an ab initio
calculation that the STM profile of our model structure compares favorably to
that obtained experimentally for both filled and empty states sampling. The
calculated local density of states shows that the nanorod is metallic in
character.Comment: 4 pages, 12 figures (inc. subfigures). Presented at the the APS March
meeting, Baltimore MD, 200
An integrated study of parallel valveless micropumps
This paper was presented at the 2nd Micro and Nano Flows Conference (MNF2009), which was held at Brunel University, West London, UK. The conference was organised by Brunel University and supported by the Institution of Mechanical Engineers, IPEM, the Italian Union of Thermofluid dynamics, the Process Intensification Network, HEXAG - the Heat Exchange Action Group and the Institute of Mathematics and its Applications.We describe an analytical, computational and experimental study of parallel valveless micropumps. A one dimensional model of a parallel micropump is presented and compared with available experimental data. The model confirms the linear decrease of the volume flux with pressure rise which is consistent with the experiments. The computational study showed a similar linear decrease but highlighted the effect of turbulence closures on the rectified mean flow, with the experimental data sitting between the turbulent and laminar closure regimes. The experimental study confirmed the importance of the displacement distance of fluid through the nozzle compared to nozzle length in the setting whether the flow regime is streaming or rectified. General conclusions are made about how to improve the pumping efficiency of micropumps.This study is supported by the Dorothy Hodgkin Postgraduate Award (DHPA) of the Engineering and Physical Sciences Research Council (EPSRC) of United Kingdom and Ebara Research Co. Ltd of Japan
Comparison of multi-year and reference year building simulations
Copyright © 2010 by SAGE PublicationsBuildings are generally modelled for compliance using reference weather years. In the UK these are the test reference year (TRY) used for energy analysis and the design summer year (DSY) used for assessing overheating in the summer. These reference years currently exist for 14 locations around the UK and consist of either a composite year compiled of the most average months from 23 years worth of observed weather data (TRY) or a single contiguous year representing a hot but non-extreme summer (DSY). In this paper, we compare simulations run using the reference years and the results obtained from simulations using the base data sets from which these reference years were chosen. We compare the posterior statistic to the reference year for several buildings examining energy use, internal temperatures, overheating and thermal comfort. We find that while the reference years allow rapid thermal modelling of building designs they are not always representative of the average energy use (TRY) exposed by modelling with many weather years. Also they do not always give an accurate indication of the internal conditions within a building and as such can give a misleading representation of the risk of overheating (DSY). Practical applications: An understanding of the limitations of the current reference years is required to allow creation of updated reference years for building simulation of future buildings. By comparing the reference years to the base data sets of historical data from which they were compiled an understanding of the benefit of multiple simulations in determining risk can be obtained
Assessing the risk of climate change for buildings: A comparison between multi-year and probabilistic reference year simulations
Copyright © 2011 Elsevier. NOTICE: this is the author’s version of a work that was accepted for publication in Building and Environment . Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Building and Environment Vol. 46 (2011), DOI: 10.1016/j.buildenv.2010.12.018Given a changing climate, there is a need to provide data for future years so that practicing engineers can investigate the impact of climate change on particular designs and examine any risk the client might be exposed to. In addition, such files are of use to building scientists in developing generic solutions to problems such as elevated internal temperatures and poor thermal comfort. With the release of the UK Climate Projections (UKCP09) [1], and the publication of a methodology for the creation of probabilistic future reference years using the UKCP09 weather generator [2], it is possible to model future building performance. However, the collapse of the distribution of possibilities inherent in the UKCP09 method into a single reference year or a small number of reference years, potentially means the loss of most of the information about the potential range of the response of the building and of the risk occupants might be subject to. In this paper we model for the first time the internal conditions and energy use of a building with all 3000 example years produced by the UKCP09 weather generator in an attempt to study the full range of response and risk. The resultant histograms and cumulative distribution functions are then used to examine whether single reference years can be used to answer questions about response and risk under a changing climate, or whether a more probabilistic approach is unavoidable
Low energy housing retrofit in North England: Overheating risks and possible mitigation strategies
In the drive to reduce space-heating demand and associated CO2 emissions as well as tackle fuel poverty, dwelling overheating and summer-time occupant thermal discomfort might be the unintended consequences of low-energy building retrofits. This paper presents the findings of a steady-state modelled low energy retrofit dwelling in northern England and its potential current and future climate overheating risks using UK Climate Projections 2009 (UKCP09) scenarios (2050 and 2080 High Emission Scenarios). Predictive findings highlight that retrofitting to low energy standards increases overheating risk over time, unless passive prevention measures are included in the retrofit design. In addition, the steady-state nature of the model might not fully capture the occupants’ exposure to actual future overheating risks. Among the most effective individual passive overheating mitigation strategies are temporary internal shading, permanent external shading, and night-time ventilation. Most effective is a combination of these adaptation measures, so that predictive overheating is minimised in a future changing climate, reducing the uptake of active cooling in retrofitted dwellings. Practical applications: Much research focuses on building overheating risks in the warmer South-east of England. However, this paper highlights how dwelling retrofit in north England (Sheffield) also can lead to increased dwelling overheating risk, unless passive design measures are included in the retrofit design. Among the most effective individual passive overheating mitigation strategies are solar shading devices and increased night-time ventilation, though ideally different measures are combined. Using future climate scenarios highlights that retrofits designed today might not be able to provide occupant thermal comfort in a future warming world
- …
