Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty
<p>Abstract</p> <p>Background</p> <p>As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem.</p> <p>Methods</p> <p>Clinical data and radiographs were reviewed from a single center for 97 randomly selected cases implanted with the Mallory-Head Porous femoral component during primary total hip arthroplasty. Measurements were taken from preoperative and long-term follow-up radiographs averaging 14 years postoperative. Average changes in the proximal, middle and diaphyseal zones were determined.</p> <p>Results</p> <p>On anteroposterior radiographs, the proximal cortical thickness was unchanged medially and the lateral zone increased 1.3%. Middle cortical thickness increased 4.3% medially and 1.2% laterally. Distal cortical thickness increased 9.6% medially and 1.9% laterally. Using the anteroposterior radiographs, canal fill at 100 mm did not correlate with bony changes at any level (Spearman's rank correlation coefficient of -0.18, 0.05, and 0.00; p value = 0.09, 0.67, 0.97). On lateral radiographs, the proximal cortical thickness increased 1.5% medially and 0.98% laterally. Middle cortical thickness increased 2.4% medially and 1.3% laterally. Distal cortical thickness increased 3.5% medially and 2.1% laterally. From lateral radiographs, canal fill at 100 mm correlated with bony hypertrophy at the proximal, mid-level, and distal femur (Spearman's rank correlation coefficient of 0.85, 0.33, and 0.28, respectively; p value = 0.001, 0.016, and 0.01, respectively).</p> <p>Conclusion</p> <p>Stress shielding is minimized with the Mallory-Head titanium tapered femoral stem with circumferential proximal plasma-sprayed coating in well-fixed and well-functioning total hip arthroplasty. Additionally, the majority of femora demonstrated increased cortical thickness in all zones around the stem prosthesis. Level of Evidence: Therapeutic Level III.</p
Periprosthetic fracture caused by stress shielding after implantation of a femoral condyle endoprosthesis in a transfemoral amputee—a case report
Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty
Background The diagnosis of hip pain after total hip replacement (THR)
represents a highly challenging question that is of increasing concern to
orthopedic surgeons. This retrospective study assesses bone scintigraphy with
Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of
patients. Methods Bone SPECT/CT datasets of 23 patients (mean age 68.9 years)
with a painful hip after THR were evaluated. Selection of the patients
required an inconclusive radiograph, normal serum levels of inflammatory
parameters (CRP and ESR) or a negative aspiration of the hip joint prior to
the examination. The standard of reference was established by an
interdisciplinary adjudication-panel using all imaging data and clinical
follow-up data (>12 month). Pathological and physiological uptake patterns
were defined and applied. Results The cause of pain in this study group could
be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5),
spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1),
septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n =
5) cases the cause of hip pain could not be identified. SPECT/CT imaging
correctly identified the cause of pain in (n = 13) cases, in which the
integrated CT-information led to the correct diagnosis in (n = 4) cases,
mainly through superior anatomic correlation. Loosening was correctly assessed
in all cases with a definite diagnosis. Conclusions SPECT/CT of THA reliably
detects or rules out loosening and provides valuable information about
heterotopic ossifications. Furthermore differential diagnoses may be detected
with a whole-body scan and mechanical or osseous failure is covered by CT-
imaging. SPECT/CT holds great potential for imaging-based assessment of
painful prostheses
Revision total hip arthroplasty using the Zweymuller femoral stem
Background: A variety of femoral stem designs have been reported to be successful in revision total hip arthroplasty without consensus as to optimal design. We evaluated the clinical and radiographic outcomes in a consecutive series of femoral revisions using a wedge-shape, tapered-stem design at medium and long-term follow-up. Materials and methods: We performed a retrospective review of clinical and radiographic outcomes of twenty-eight consecutive femoral revisions arthroplasties, which were done using the Zweymuller femoral stem. Results: The mean follow-up was 7.4 years (range 2-15 years). No stem re-revision was necessary. All stems were judged to be stable by radiographic criteria at the most recent follow-up. The final mean Harris hip score was 90. There was no difference in Harris hip scores, implant stability, or radiological appearance (distal cortical hypertrophy or proximal stress shielding) of the implants between medium-term (mean 5.7 years) and long-term (mean 12.4 years) follow-up. Conclusions: We found the Zweymuller femoral stem design to be durable for revision hip arthroplasty when there is an intact metaphyseal-diaphyseal junction for adequate press-fit stability at surgery. © Springer-Verlag 2008
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Finite element analysis of cementless femoral stems based on mid- and long-term radiological evaluation
Custom stems for femoral deformity in patients less than 40 years of age: 70 hips followed for an average of 14 years
Background and purpose Femoral deformity associated with osteoarthritis is a challenge for both the surgeon and the implant. Many of the patients with these deformities are young. Standard implants can be difficult to fit into these femurs. We prospectively evaluated the outcome of custom uncemented femoral stems in young patients
Wild chimpanzees modify modality of gestures according to the strength of social bonds and personal network size
Primates form strong and enduring social bonds with others and these bonds have important fitness consequences. However, how different types of communication are associated with different types of social bonds is poorly understood. Wild chimpanzees have a large repertoire of gestures, from visual gestures to tactile and auditory gestures. We used social network analysis to examine the association between proximity bonds (time spent in close proximity) and rates of gestural communication in pairs of chimpanzees when the intended recipient was within 10 m of the signaller. Pairs of chimpanzees with strong proximity bonds had higher rates of visual gestures, but lower rates of auditory long-range and tactile gestures. However, individual chimpanzees that had a larger number of proximity bonds had higher rates of auditory and tactile gestures and lower rates of visual gestures. These results suggest that visual gestures may be an efficient way to communicate with a small number of regular interaction partners, but that tactile and auditory gestures may be more effective at communicating with larger numbers of weaker bonds. Increasing flexibility of communication may have played an important role in managing differentiated social relationships in groups of increasing size and complexity in both primate and human evolution
Congenital hip dysplasia treated by total hip arthroplasty using cementless tapered stem in patients younger than 50 years old: results after 12-years follow-up
Background
Congenital hip dysplasia may lead to severe acetabular and femoral abnormalities that can make total hip arthroplasty a challenging procedure. We assessed a series of patients affected by developmental hip dysplasia treated with total hip arthroplasty using cementless tapered stem and here we report the outcomes at long-term follow-up.
Materials and methods
Twenty-eight patients (24 women and 4 men) aged between 44 and 50 years (mean 47 years) were observed. Clinical evaluation was rated with the Harris Hip Score. Radiographic evaluation consisted in standard anteroposterior and axial view radiographs of the hip. According to Crowe’s classification, 16 hips presented dysplasia grade 1, 14 grade 2, and 4 grade 3. All patients were treated with total hip arthroplasty using a cementless tapered stem (Wagner Cone Prosthesis). Six patients were operated bilaterally, with a totally of 34 hips operated. After surgery, the patients were clinically and radiographically checked at 3, 6, and 12 months and yearly thereafter until an average follow-up of 12 years (range 10–14 years).
Results
Average Harris Hip Score was 56 ± 9 (range 45–69) preoperatively, 90 ± 9 (range 81–100) 12 months after surgery, and 91 ± 8 (range 83–100) at last follow-up. Radiographic evaluation demonstrated excellent osteointegration of the implants. Signs of bone resorption were present in 6 hips, nevertheless no evidence of loosening was observed and none of the implants has been revised.
Conclusions
Even in dysplasic femur, the tapered stem allowed adequate stability and orientation of the implant. We consider tapered stem a suitable option for total hip arthroplasty in developmental hip dysplasia, also in case of young patients, thanks to the favourable long-term results
- …