764 research outputs found

    Safety of the Deferral of Coronary Revascularization on the Basis of Instantaneous Wave-Free Ratio and Fractional Flow Reserve Measurements in Stable Coronary Artery Disease and Acute Coronary Syndromes.

    Get PDF
    OBJECTIVES: The aim of this study was to investigate the clinical outcomes of patients deferred from coronary revascularization on the basis of instantaneous wave-free ratio (iFR) or fractional flow reserve (FFR) measurements in stable angina pectoris (SAP) and acute coronary syndromes (ACS). BACKGROUND: Assessment of coronary stenosis severity with pressure guidewires is recommended to determine the need for myocardial revascularization. METHODS: The safety of deferral of coronary revascularization in the pooled per-protocol population (n = 4,486) of the DEFINE-FLAIR (Functional Lesion Assessment of Intermediate Stenosis to Guide Revascularisation) and iFR-SWEDEHEART (Instantaneous Wave-Free Ratio Versus Fractional Flow Reserve in Patients With Stable Angina Pectoris or Acute Coronary Syndrome) randomized clinical trials was investigated. Patients were stratified according to revascularization decision making on the basis of iFR or FFR and to clinical presentation (SAP or ACS). The primary endpoint was major adverse cardiac events (MACE), defined as the composite of all-cause death, nonfatal myocardial infarction, or unplanned revascularization at 1 year. RESULTS: Coronary revascularization was deferred in 2,130 patients. Deferral was performed in 1,117 patients (50%) in the iFR group and 1,013 patients (45%) in the FFR group (p < 0.01). At 1 year, the MACE rate in the deferred population was similar between the iFR and FFR groups (4.12% vs. 4.05%; fully adjusted hazard ratio: 1.13; 95% confidence interval: 0.72 to 1.79; p = 0.60). A clinical presentation with ACS was associated with a higher MACE rate compared with SAP in deferred patients (5.91% vs. 3.64% in ACS and SAP, respectively; fully adjusted hazard ratio: 0.61 in favor of SAP; 95% confidence interval: 0.38 to 0.99; p = 0.04). CONCLUSIONS: Overall, deferral of revascularization is equally safe with both iFR and FFR, with a low MACE rate of about 4%. Lesions were more frequently deferred when iFR was used to assess physiological significance. In deferred patients presenting with ACS, the event rate was significantly increased compared with SAP at 1 year.info:eu-repo/semantics/publishedVersio

    Combined optical coherence tomography morphologic and fractional flow reserve hemodynamic assessment of non- culprit lesions to better predict adverse event outcomes in diabetes mellitus patients: COMBINE (OCT–FFR) prospective study. Rationale and design

    Get PDF
    Contains fulltext : 172158.pdf (publisher's version ) (Open Access)BACKGROUND: Fractional flow reserve (FFR) is a widely used tool for the identification of ischaemia-generating stenoses and to guide decisions on coronary revascularisation. However, the safety of FFR-based decisions in high-risk subsets, such as patients with Diabetes Mellitus (DM) or vulnerable stenoses presenting thin-cap fibro-atheroma (TCFA), is unknown. This study will examine the impact of optical coherence tomography (OCT) plaque morphological assessment and the identification of TCFA, in combination with FFR to better predict clinical outcomes in DM patients. METHODS: COMBINE (OCT-FFR) is a prospective, multi-centre study investigating the natural history of DM patients with >/=1 angiographically intermediate target lesion in three subgroups of patients; patients with FFR negative lesions without TCFA (group A) and patients with FFR negative lesions with TCFA (group B) as detected by OCT and to compare these two groups with each other, as well as to a third group with FFR-positive, PCI-treated intermediate lesions (group C). The study hypothesis is that DM patients with TCFA (group B) have a worse outcome than those without TCFA (group A) and also when compared to those patients with lesions FFR </=0.80 who underwent complete revascularisation. The primary endpoint is the incidence of target lesion major adverse cardiac events (MACE); a composite of cardiac death, myocardial infarction or rehospitalisation for unstable/progressive angina in group B vs. group A. CONCLUSION: COMBINE (OCT-FFR) is the first prospective study to examine whether the addition of OCT plaque morphological evaluation to FFR haemodynamic assessment of intermediate lesions in DM patients will better predict MACE and possibly lead to new revascularisation strategies. Trial Registration Netherlands Trial Register: NTR5376

    Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial.

    Get PDF
    Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomes of a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesium scaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novo lesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at 6 months, and-if subjects consented-at 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42 patients: in-segment late lumen loss 0.20 ± 0.21 mm vs. 0.25 ± 0.22 mm, P = 0.117, Δ 0.05 ± 0.21 mm (95% CI: -0.01;0.12); in-scaffold late lumen loss 0.37 ± 0.25 mm vs. 0.39 ± 0.27 mm, P = 0.446, Δ 0.03 ± 0.22 (95% CI: -0.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroborated the QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause, one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional event occurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienced a definite or probable scaffold thrombosis. The novel drug-eluting metal absorbable scaffold DREAMS 2G showed a continuous favourable safety profile up to 12 months and stable angiographic parameters between 6 and 12 months. NCT01960504

    Ischemia-Related Lesion Characteristics in Patients With Stable or Unstable Angina

    Get PDF
    Background Postmortem-derived findings support the common beliefs that lipid-rich coronary plaques with a thin, fibrous cap are prone to rupture and that rupture and superimposed thrombosis are the primary mechanisms causing acute coronary syndromes. In vivo imaging with intracoronary techniques may disclose differences in the characterization of atherosclerotic plaques in patients with stable or unstable angina and thus may provide clues to which plaques may rupture and whether rupture and thrombosis are active. Methods and Results We assessed the characteristics of the ischemia-related lesions with coronary angiography and intracoronary angioscopy and determined their compositions with intracoronary ultrasound in 44 patients with unstable and 23 patients with stable angina. The angiographic images were classified as noncomplex (smooth borders) or complex (irregular borders, multiple lesions, thrombus). Angioscopic images were classified as either stable (smooth surface) or thrombotic (red thrombus). The ultrasound characteristics of the lesion were classified as poorly echo-reflective, highly echo-reflective with shadowing, or highly echo-reflective without shadowing. There was a poor correlation between clinical status and angiographic findings. An angiographic complex lesion (n=33) was concordant with unstable angina in 55% (24 of 44); a noncomplex lesion (n=34) was concordant with stable angina in 61% (14 of 23). There was a good correlation between clinical status and angioscopic findings. An angioscopic thrombotic lesion (n=34) was concordant with unstable angina in 68% (30 of 44); a stable lesion (n=33) was concordant with stable angina in 83% (19 of 23). The ultrasound-obtained composition of the plaque was similar in patients with unstable and stable angina. Conclusions Angiography discriminates poorly between lesions in stable and unstable angina. Angioscopy demonstrated that plaque rupture and thrombosis were present in 17% of stable angina and 68% of unstable angina patients. Currently available ultrasound technology does not discriminate stable from unstable plaques

    Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial

    Get PDF
    Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-u

    Reducing Microvascular Dysfunction in Revascularized Patients with ST-Elevation Myocardial Infarction by Off-Target Properties of Ticagrelor versus Prasugrel. Rationale and Design of the REDUCE-MVI Study

    Get PDF
    Microvascular injury is present in a large proportion of patients with ST-elevation myocardial infarction (STEMI) despite successful revascularization. Ticagrelor potentially mitigates this process by exerting additional adenosine-mediated effects. This study aims to determine whether ticagrelor is associated with a better microvascular function compared to prasugrel as maintenance therapy after STEMI. A total of 110 patients presenting with STEMI and additional intermediate stenosis in another coronary artery will be studied after successful percutaneous coronary intervention (PCI) of the infarct-related artery. Patients will be randomized to treatment with ticagrelor or prasugrel for 1 year. FFR-guided PCI of the non-infarct-related artery will be performed at 1 month. Microvascular function will be assessed by measurement of the index of microcirculatory resistance (IMR) in the infarct-related artery and non-infarct-related artery, immediately after primary PCI and after 1 month. The REDUCE-MVI study will establish whether ticagrelor as a maintenance therapy may improve microvascular function in patients after revascularized STEMI
    corecore