226 research outputs found
PMT Test Facility at MPIK Heidelberg and Double Chooz Super Vertical Slice
Proceedings supplement for conference poster at Neutrino 2010, Athens,
Greece
Transit Time and Charge Correlations of Single Photoelectron Events in R7081 PMTs
During the calibration phase of the photomultiplier tubes (PMT) for the
Double Chooz experiment the PMT response to light with single photoelectron
(SPE) intensity was analysed. With our setup we were able to measure the
combined transit time and charge response of the PMT and therefore we could
deconstruct and analyse all physical effects having an influence on the PMT
signal. Based on this analysis charge and time correlated probability density
functions were developed to include the PMT response in a Monte Carlo
simulation.Comment: minor changes by referee reques
Transit Time and Charge Correlations of Single Photoelectron Events in R7081 PMTs
During the calibration phase of the photomultiplier tubes (PMT) for the
Double Chooz experiment the PMT response to light with single photoelectron
(SPE) intensity was analysed. With our setup we were able to measure the
combined transit time and charge response of the PMT and therefore we could
deconstruct and analyse all physical effects having an influence on the PMT
signal. Based on this analysis charge and time correlated probability density
functions were developed to include the PMT response in a Monte Carlo
simulation.Comment: minor changes by referee reques
Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment
The hemispherical 10" photomultiplier tube (PMT) R7081 from Hamamatsu
Photonics K.K. (HPK) is used in various experiments in particle and
astroparticle physics. We describe the test and calibration of 474 PMTs for the
reactor antineutrino experiment Double Chooz. The unique test setup at
Max-Planck-Institut f\"ur Kernphysik Heidelberg (MPIK) allows one to calibrate
30 PMTs simultaneously and to characterize the single photo electron response,
transit time spread, linear behaviour and saturation effects, photon detection
efficiency and high voltage calibration
Qualification Tests of the R11410-21 Photomultiplier Tubes for the XENON1T Detector
The Hamamatsu R11410-21 photomultiplier tube is the photodetector of choice
for the XENON1T dual-phase time projection chamber. The device has been
optimized for a very low intrinsic radioactivity, a high quantum efficiency and
a high sensitivity to single photon detection. A total of 248 tubes are
currently operated in XENON1T, selected out of 321 tested units. In this
article the procedures implemented to evaluate the large number of tubes prior
to their installation in XENON1T are described. The parameter distributions for
all tested tubes are shown, with an emphasis on those selected for XENON1T, of
which the impact on the detector performance is discussed. All photomultipliers
have been tested in a nitrogen atmosphere at cryogenic temperatures, with a
subset of the tubes being tested in gaseous and liquid xenon, simulating their
operating conditions in the dark matter detector. The performance and
evaluation of the tubes in the different environments is reported and the
criteria for rejection of PMTs are outlined and quantified.Comment: 24 pages, 16 figure
Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment
The hemispherical 10" photomultiplier tube (PMT) R7081 from Hamamatsu
Photonics K.K. (HPK) is used in various experiments in particle and
astroparticle physics. We describe the test and calibration of 474 PMTs for the
reactor antineutrino experiment Double Chooz. The unique test setup at
Max-Planck-Institut f\"ur Kernphysik Heidelberg (MPIK) allows one to calibrate
30 PMTs simultaneously and to characterize the single photo electron response,
transit time spread, linear behaviour and saturation effects, photon detection
efficiency and high voltage calibration
Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment
The hemispherical 10" photomultiplier tube (PMT) R7081 from Hamamatsu
Photonics K.K. (HPK) is used in various experiments in particle and
astroparticle physics. We describe the test and calibration of 474 PMTs for the
reactor antineutrino experiment Double Chooz. The unique test setup at
Max-Planck-Institut f\"ur Kernphysik Heidelberg (MPIK) allows one to calibrate
30 PMTs simultaneously and to characterize the single photo electron response,
transit time spread, linear behaviour and saturation effects, photon detection
efficiency and high voltage calibration
The BNO-LNGS joint measurement of the solar neutrino capture rate in 71Ga
We describe a cooperative measurement of the capture rate of solar neutrinos
by the reaction 71Ga(\nu_e,e^-)71Ge. Extractions were made from a portion of
the gallium target in the Russian-American Gallium Experiment SAGE and the
extraction samples were transported to the Gran Sasso laboratory for synthesis
and counting at the Gallium Neutrino Observatory GNO. Six extractions of this
type were made and the resultant solar neutrino capture rate was 64
^{+24}_{-22} SNU, which agrees well with the overall result of the gallium
experiments. The major purpose of this experiment was to make it possible for
SAGE to continue their regular schedule of monthly solar neutrino extractions
without interruption while a separate experiment was underway to measure the
response of 71Ga to neutrinos from an 37Ar source. As side benefits, this
experiment proved the feasibility of long-distance sample transport in ultralow
background radiochemical experiments and familiarized each group with the
methods and techniques of the other.Comment: 7 pages, no figures; minor additions in version
Searching for sterile neutrinos in ice
Oscillation interpretation of the results from the LSND, MiniBooNE and some
other experiments requires existence of sterile neutrino with mass eV
and mixing with the active neutrinos . It has
been realized some time ago that existence of such a neutrino affects
significantly the fluxes of atmospheric neutrinos in the TeV range which can be
tested by the IceCube Neutrino Observatory. In view of the first IceCube data
release we have revisited the oscillations of high energy atmospheric neutrinos
in the presence of one sterile neutrino. Properties of the oscillation
probabilities are studied in details for various mixing schemes both
analytically and numerically. The energy spectra and angular distributions of
the events have been computed for the simplest mass, and
mixing schemes and confronted with the IceCube data. An
illustrative statistical analysis of the present data shows that in the
mass mixing case the sterile neutrinos with parameters required by
LSND/MiniBooNE can be excluded at about level. The
mixing scheme, however, can not be ruled out with currently available IceCube
data.Comment: 41 pages, 16 figures. Accepted for publication in JHEP. Minor changes
from the previous versio
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.Comment: 3 pages, no figure
- …
