1,472 research outputs found
Gravitational Wave Radiation from Compact Binary Systems in the Jordan-Brans-Dicke Theory
In this paper we analyze the signal emitted by a compact binary system in the Jordan-Brans-Dicke theory. We compute the scalar and tensor components of the power radiated by the source and study the scalar waveform. Eventually we consider the detectability of the scalar component of the radiation by interferometers and resonant-mass detectors
Quark nuggets search using 2350 Kg gravitational waves aluminum bar detectors
The gravitational wave resonant detectors can be used as detectors of quark
nuggets, like nuclearites (nuclear matter with a strange quark). This search
has been carried out using data from two 2350 Kg, 2 K cooled, aluminum bar
detectors: NAUTILUS, located in Frascati (Italy), and EXPLORER, that was
located in CERN Geneva (CH). Both antennas are equipped with cosmic ray shower
detectors: signals in the bar due to showers are continuously detected and used
to characterize the antenna performances. The bar excitation mechanism is based
on the so called thermo-acoustic effect, studied on dedicated experiments that
use particle beams. This mechanism predicts that vibrations of bars are induced
by the heat deposited in the bar from the particle. The geometrical acceptance
of the bar detectors is 19.5 sr, that is smaller than that of other
detectors used for similar searches. However, the detection mechanism is
completely different and is more straightforward than in other detectors. We
will show the results of ten years of data from NAUTILUS (2003-2012) and 7
years from EXPLORER (2003-2009). The experimental limits we obtain are of
interest because, for nuclearites of mass less than grams, we find a
flux smaller than that one predicted considering nuclearites as dark matter
candidates.Comment: presented to the 33rd International Cosmic Ray Conference Rio de
Janeiro 201
Measurement of the thermal expansion coefficient of an Al-Mg alloy at ultra-low temperatures
We describe a result coming from an experiment based on an Al-Mg alloy (~ 5%
Mg) suspended bar hit by an electron beam and operated above and below the
termperature of transition from superconducting to normal state of the
material. The amplitude of the bar first longitudinal mode of oscillation,
excited by the beam interacting with the bulk, and the energy deposited by the
beam in the bar are the quantities measured by the experiment. These
quantities, inserted in the equations describing the mechanism of the mode
excitation and complemented by an independent measurement of the specific heat,
allow us to determine the linear expansion coefficient of the material.Comment: 13 pages, 4 figure
Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K
We present the performances and the strain sensitivity of the first spherical
gravitational wave detector equipped with a capacitive transducer and read out
by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K.
We characterized the detector performance in terms of thermal and electrical
noise in the system output sygnal. We measured a peak strain sensitivity of
at 2942.9 Hz. A strain sensitivity of better than
has been obtained over a bandwidth of 30 Hz. We expect
an improvement of more than one order of magnitude when the detector will
operate at 50 mK. Our results represent the first step towards the development
of an ultracryogenic omnidirectional detector sensitive to gravitational
radiation in the 3kHz range.Comment: 8 pages, 5 figures, submitted to Physical Review
Analysis of 3 years of data from the gravitational wave detectors EXPLORER and NAUTILUS
We performed a search for short gravitational wave bursts using about 3 years
of data of the resonant bar detectors Nautilus and Explorer. Two types of
analysis were performed: a search for coincidences with a low background of
accidentals (0.1 over the entire period), and the calculation of upper limits
on the rate of gravitational wave bursts. Here we give a detailed account of
the methodology and we report the results: a null search for coincident events
and an upper limit that improves over all previous limits from resonant
antennas, and is competitive, in the range h_rss ~1E-19, with limits from
interferometric detectors. Some new methodological features are introduced that
have proven successful in the upper limits evaluation.Comment: 12 pages, 12 figure
Effect of cosmic rays on the resonant gravitational wave detector NAUTILUS at temperature T=1.5 K
The interaction between cosmic rays and the gravitational wave bar detector
NAUTILUS is experimentally studied with the aluminum bar at temperature of
T=1.5 K. The results are compared with those obtained in the previous runs when
the bar was at T=0.14 K. The results of the run at T = 1.5 K are in agreement
with the thermo-acoustic model; no large signals at unexpected rate are
noticed, unlike the data taken in the run at T = 0.14 K. The observations
suggest a larger efficiency in the mechanism of conversion of the particle
energy into vibrational mode energy when the aluminum bar is in the
superconductive status.Comment: 7 pages, 3 figures, 2 tables. Accepted by Physics Letters
Dark Matter searches using gravitational wave bar detectors: quark nuggets and newtorites
Many experiments have searched for supersymmetric WIMP dark matter, with null
results. This may suggest to look for more exotic possibilities, for example
compact ultra-dense quark nuggets, widely discussed in literature with several
different names. Nuclearites are an example of candidate compact objects with
atomic size cross section. After a short discussion on nuclearites, the result
of a nuclearite search with the gravitational wave bar detectors Nautilus and
Explorer is reported. The geometrical acceptance of the bar detectors is 19.5
sr, that is smaller than that of other detectors used for similar
searches. However, the detection mechanism is completely different and is more
straightforward than in other detectors. The experimental limits we obtain are
of interest because, for nuclearites of mass less than g, we find a
flux smaller than that one predicted considering nuclearites as dark matter
candidates. Particles with gravitational only interactions (newtorites) are
another example. In this case the sensitivity is quite poor and a short
discussion is reported on possible improvements.Comment: published on Astroparticle Physics Sept 25th 2016 replaced fig 1
MiniGRAIL progress report 2004
The MiniGRAIL detector was improved. The sphere was replaced by a slightly larger one, having a diameter of 68 cm (instead of 65 cm), reducing the resonant frequency by about 200 Hz to around 2.9 kHz. The last four masses of the attenuation system were machined to increase their resonant frequency and improve the attenuation around the resonant frequency of the sphere. In the new sphere, six holes were machined on the TIGA positions for easy mounting of the transducers. During the last cryogenic run, two capacitive transducers and a calibrator were mounted on the sphere. The first transducer was coupled to a double-stage SQUID amplifier having a commercial quantum design SQUID as a first stage and a DROS as a second stage. The second transducer was read by a single-stage quantum design SQUID. During the cryogenic run, the sphere was cooled down to 4 K. The two-stage SQUID had a flux noise of about 1.6 μ0 Hz−1/2. The detector was calibrated and the sensitivity curve of MiniGRAIL was determined
Particle acoustic detection in gravitational wave aluminum resonant antennas
The results on cosmic rays detected by the gravitational antenna NAUTILUS
have motivated an experiment (RAP) based on a suspended cylindrical bar, which
is made of the same aluminum alloy as NAUTILUS and is exposed to a high energy
electron beam. Mechanical vibrations originate from the local thermal expansion
caused by warming up due to the energy lost by particles crossing the material.
The aim of the experiment is to measure the amplitude of the fundamental
longitudinal vibration at different temperatures. We report on the results
obtained down to a temperature of about 4 K, which agree at the level of about
10% with the predictions of the model describing the underlying physical
process.Comment: RAP experiment, 16 pages, 7 figure
- …
