25 research outputs found

    Study of the reaction e^{+}e^{-} -->J/psi\pi^{+}\pi^{-} via initial-state radiation at BaBar

    Get PDF
    We study the process e+eJ/ψπ+πe^+e^-\to J/\psi\pi^{+}\pi^{-} with initial-state-radiation events produced at the PEP-II asymmetric-energy collider. The data were recorded with the BaBar detector at center-of-mass energies 10.58 and 10.54 GeV, and correspond to an integrated luminosity of 454 fb1\mathrm{fb^{-1}}. We investigate the J/ψπ+πJ/\psi \pi^{+}\pi^{-} mass distribution in the region from 3.5 to 5.5 GeV/c2\mathrm{GeV/c^{2}}. Below 3.7 GeV/c2\mathrm{GeV/c^{2}} the ψ(2S)\psi(2S) signal dominates, and above 4 GeV/c2\mathrm{GeV/c^{2}} there is a significant peak due to the Y(4260). A fit to the data in the range 3.74 -- 5.50 GeV/c2\mathrm{GeV/c^{2}} yields a mass value 4244±54244 \pm 5 (stat) ±4 \pm 4 (syst)MeV/c2\mathrm{MeV/c^{2}} and a width value 11415+16114 ^{+16}_{-15} (stat)±7 \pm 7(syst)MeV\mathrm{MeV} for this state. We do not confirm the report from the Belle collaboration of a broad structure at 4.01 GeV/c2\mathrm{GeV/c^{2}}. In addition, we investigate the π+π\pi^{+}\pi^{-} system which results from Y(4260) decay

    Observation of the Gamma-Ray Binary HESS J0632+057 with the HESS, MAGIC, and VERITAS Telescopes

    Get PDF
    The results of gamma-ray observations of the binary system HESS J0632 + 057 collected during 450 hr over 15 yr, between 2004 and 2019, are presented. Data taken with the atmospheric Cherenkov telescopes H.E.S.S., MAGIC, and VERITAS at energies above 350 GeV were used together with observations at X-ray energies obtained with Swift-XRT, Chandra, XMM-Newton, NuSTAR, and Suzaku. Some of these observations were accompanied by measurements of the H alpha emission line. A significant detection of the modulation of the very high-energy gamma-ray fluxes with a period of 316.7 +/- 4.4 days is reported, consistent with the period of 317.3 +/- 0.7 days obtained with a refined analysis of X-ray data. The analysis of data from four orbital cycles with dense observational coverage reveals short-timescale variability, with flux-decay timescales of less than 20 days at very high energies. Flux variations observed over a timescale of several years indicate orbit-to-orbit variability. The analysis confirms the previously reported correlation of X-ray and gamma-ray emission from the system at very high significance, but cannot find any correlation of optical H alpha parameters with fluxes at X-ray or gamma-ray energies in simultaneous observations. The key finding is that the emission of HESS J0632 + 057 in the X-ray and gamma-ray energy bands is highly variable on different timescales. The ratio of gamma-ray to X-ray flux shows the equality or even dominance of the gamma-ray energy range. This wealth of new data is interpreted taking into account the insufficient knowledge of the ephemeris of the system, and discussed in the context of results reported on other gamma-ray binary systems

    Energy Distribution of Electrons Excited by Slow Particles in Solids

    No full text

    The Correlates of Body Composition with Heart Rate Recovery after Step Test: An Exploratory Study of Malaysian Adolescents

    Get PDF
    BACKGROUND: In adults, heart rate recovery is a predictor of mortality, while in adolescents it is associated with cardio-metabolic risk factors. The aim of this study was to examine the relationship between body composition measures and heart rate recovery (HRR) after step test in Malaysian secondary school students. METHODS: In the Malaysian Health and Adolescents Longitudinal Research Team (MyHEART) study, 1071 healthy secondary school students, aged 13 years old, participated in the step test. Parameters for body composition measures were body mass index z-score, body fat percentage, waist circumference, and waist height ratio. The step test was conducted by using a modified Harvard step test. Heart rate recovery of 1 minute (HRR1min) and heart rate recovery of 2 minutes (HRR2min) were calculated by the difference between the peak pulse rate during exercise and the resting pulse rate at 1 and 2 minutes, respectively. Analysis was done separately based on gender. Pearson correlation analysis was used to determine the association between the HRR parameters with body composition measures, while multiple regression analysis was used to determine which body composition measures was the strongest predictor for HRR. RESULTS: For both gender groups, all body composition measures were inversely correlated with HRR1min. In girls, all body composition measures were inversely correlated with HRR2min, while in boys all body composition measures, except BMI z-score, were associated with HRR2min. In multiple regression, only waist circumference was inversely associated with HRR2min (p=0.024) in boys, while in girls it was body fat percentage for HRR2min (p=0.008). CONCLUSION: There was an inverse association between body composition measurements and HRR among apparently healthy adolescents. Therefore, it is important to identify cardio-metabolic risk factors in adolescent as an early prevention of consequent adulthood morbidity. This reiterates the importance of healthy living which should start from young

    A Systematic Review and Meta-Analysis of Fecal Contamination and Inadequate Treatment of Packaged Water

    Get PDF
    <div><p>Background</p><p>Packaged water products provide an increasingly important source of water for consumption. However, recent studies raise concerns over their safety.</p><p>Objectives</p><p>To assess the microbial safety of packaged water, examine differences between regions, country incomes, packaged water types, and compare packaged water with other water sources.</p><p>Methods</p><p>We performed a systematic review and meta-analysis. Articles published in English, French, Portuguese, Spanish and Turkish, with no date restrictions were identified from online databases and two previous reviews. Studies published before April 2014 that assessed packaged water for the presence of <i>Escherichia coli</i>, thermotolerant or total coliforms were included provided they tested at least ten samples or brands.</p><p>Results</p><p>A total of 170 studies were included in the review. The majority of studies did not detect fecal indicator bacteria in packaged water (78/141). Compared to packaged water from upper-middle and high-income countries, packaged water from low and lower-middle-income countries was 4.6 (95% CI: 2.6–8.1) and 13.6 (95% CI: 6.9–26.7) times more likely to contain fecal indicator bacteria and total coliforms, respectively. Compared to all other packaged water types, water from small bottles was less likely to be contaminated with fecal indicator bacteria (OR = 0.32, 95%CI: 0.17–0.58) and total coliforms (OR = 0.10, 95%CI: 0.05, 0.22). Packaged water was less likely to contain fecal indicator bacteria (OR = 0.35, 95%CI: 0.20, 0.62) compared to other water sources used for consumption.</p><p>Conclusions</p><p>Policymakers and regulators should recognize the potential benefits of packaged water in providing safer water for consumption at and away from home, especially for those who are otherwise unlikely to gain access to a reliable, safe water supply in the near future. To improve the quality of packaged water products they should be integrated into regulatory and monitoring frameworks.</p></div
    corecore