24 research outputs found

    Similar Performance of Trabectome and Ahmed Glaucoma Devices in a Propensity Score-matched Comparison

    Get PDF
    Purpose: To apply propensity score matching to Ahmed glaucoma drainage implants (AGI) to trabectome-mediated ab interno trabeculectomy (AIT). Recent data suggest that AIT can produce results similar to AGI traditionally reserved for more severe glaucoma. Methods: AGI and AIT patients with at least 1 year of follow-up were included. The primary outcome measures were intraocular pressure (IOP), glaucoma medications, and a Glaucoma Index (GI) score. GI reflected glaucoma severity based on visual field, the number of preoperative medications, and preoperative IOP. Score matching used a genetic algorithm consisting of age, sex, type of glaucoma, concurrent phacoemulsification, baseline number of medications, and baseline IOP. Patients without a close match were excluded. Results: Of 152 patients, 34 AIT patients were matched to 32 AGI patients. Baseline characteristics including ethnicity, IOP, the number of medications, glaucoma type, the degree of visual field loss and GI were not significantly different between AIT and AGI. AIT had a preoperative IOP of 23.6±8.1 mm Hg compared with 26.5+10.6 mm Hg for AGI. At 12 months, the mean IOP was 15.0±9 mm Hg for AIT versus 15.0±4 mm Hg for AGI (P=0.8), whereas the number of drops was 2.3±2.2 for AIT versus 3.6±1.3 for AGI (P=0.016). Only 6 AIT patients (17.6%) required further surgery within the first 12 months versus 9 (28%) for AGI. Success, defined as IOP<21 mm Hg, <20% reduction and no reoperation, was achieved in 76% of AIT versus 69% of AGI (P=0.48). Complications occurred in 13% of AGI and 0.8% of AIT. Conclusions: A propensity score-matched comparison of AIT and AGI showed an equivalent IOP reduction through 1 year. Surprisingly, the AGI group required more glaucoma medications than the AIT group at 6 and 12 months

    Individual Canine Airway Response Variability to a Deep Inspiration

    Get PDF
    In healthy individuals, a DI can reverse (bronchodilation) or prevent (bronchoprotection) induced airway constriction. For individuals with asthma or COPD, these effects may be attenuated or absent. Previous work showed that the size and duration of a DI affected the subsequent response of the airways. Also, increased airway tone lead to increased airway size variability. The present study examined how a DI affected the temporal variability in individual airway baseline size and after methacholine challenge in dogs using High-Resolution Computed Tomography. Dogs were anesthetized and ventilated, and on 4 separate days, HRCT scans were acquired before and after a DI at baseline and during a continuous intravenous infusion of methacholine (Mch) at 3 dose rates (17, 67, and 200 μg/min). The Coefficient of Variation was used as an index of temporal variability in airway size

    Development of Clinical Markers to Avoid Unnecessary Temporal Artery Biopsy in Giant Cell Arteritis

    No full text
    Giant cell arteritis (GCA) is a medium-to-large vessel vasculitis that, untreated, can cause blindness, myocardial infarction, and cerebral ischemia. Presentation may be highly nonspecific, resulting in potentially morbid treatment with steroids and temporal artery biopsy (TAB)

    Continuous flow chemistry

    No full text

    Training strategies and outcomes of ab interno trabeculectomy with the trabectome

    No full text
    Plasma-mediated ab interno trabeculectomy with the trabectome was first approved by the US Food and Drug Administration in 2004 for use in adult and pediatric glaucomas. Since then, increased clinical experience and updated outcome data have led to its expanded use, including a range of glaucomas and angle presentations, previously deemed to be relatively contraindicated. The main benefits are a high degree of safety, ease, and speed compared to traditional filtering surgery and tube shunts. The increasing burden of glaucoma and expanding life expectancy has resulted in demand for well-trained surgeons. In this article, we discuss the results of trabectome surgery in standard and nonstandard indications. We present training strategies of the surgical technique that include a pig eye model, and visualization exercises that can be performed before and at the conclusion of standard cataract surgery in patients who do not have glaucoma. We detail the mechanism of enhancing the conventional outflow pathway and describe methods of visualization and function testing.</ns4:p

    Visual Outcomes of Diabetics and Prognostic Factors in Non -Arteritic Ischaemic Optic Neuropathy (.pdf)

    No full text
    Diabetics have a greater risk of non arteritic ischemic optic neuropathy (NAION) but visual outcomes compared with non-diabetics are unknown. Aims: To compare visual outcomes, prevalence of bilateral /sequential ION and risk factors for NAION in diabetics and non diabetics. To identify prognostic factors for poor visual outcomes in NAIO

    Training strategies and outcomes of ab interno trabeculectomy with the trabectome [version 2; referees: 2 approved]

    No full text
    Plasma-mediated ab interno trabeculectomy with the trabectome was first approved by the US Food and Drug Administration in 2004 for use in adult and pediatric glaucomas. Since then, increased clinical experience and updated outcome data have led to its expanded use, including a range of glaucomas and angle presentations, previously deemed to be relatively contraindicated. The main benefits are a high degree of safety, ease, and speed compared to traditional filtering surgery and tube shunts. The increasing burden of glaucoma and expanding life expectancy has resulted in demand for well-trained surgeons. In this article, we discuss the results of trabectome surgery in standard and nonstandard indications. We present training strategies of the surgical technique that include a pig eye model, and visualization exercises that can be performed before and at the conclusion of standard cataract surgery in patients who do not have glaucoma. We detail the mechanism of enhancing the conventional outflow pathway and describe methods of visualization and function testing
    corecore