124 research outputs found
Strings of droplets propelled by coherent waves
Bouncing walking droplets possess fascinating properties due to their
peculiar wave/particule interaction. In order to study such walkers in a 1d
system, we considered the case of one or more droplets in an annular cavity. We
show that, in this geometry, walking droplets form a string of synchronized
bouncing droplets that share a common coherent wave propelling the group at a
speed faster than single walkers. The formation of this coherent wave and the
collective behavior of droplets is captured by a model.Comment: 5 Pages, 5 Figures, 2 supplementary movies (identical), supplementary
.pdf fil
Waveguides for walking droplets
When gently placing a droplet onto a vertically vibrated bath, a drop can
bounce without coalescing. Upon increasing the forcing acceleration, the
droplet is propelled by the wave it generates and becomes a walker with a well
defined speed. We investigate the confinement of a walker in different
rectangular cavities, used as waveguides for the Faraday waves emitted by
successive droplet bounces. By studying the walker velocities, we discover that
1d confinement is optimal for narrow channels of width of . We also propose an analogy with waveguide models based on the
observation of the Faraday instability within the channels.Comment: 8 pages, 6 figure
Recommended from our members
Pulse-Encoded Ultrasound Imagine of the Vitreous With an Annular Array
The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved 20-MHz five-element annular array ultrasound transducer, implemented a synthetic-focusing algorithm to extend the depth-of-field, and used a pulse-encoding strategy to increase sensitivity. The authors evaluated a human subject with a recent posterior vitreous detachment and compared the annular array with conventional 10-MHz ultrasound and spectral-domain optical coherence tomography. With synthetic focusing and chirp pulse-encoding, the array allowed visualization of the formed and fluid components of the vitreous with improved sensitivity and resolution compared with the conventional B-scan. Although optical coherence tomography allowed assessment of the posterior vitreoretinal interface, the ultrasound array allowed evaluation of the entire vitreous body
Recommended from our members
Non-Planar Pad-Printed Think-Film Focused High-Frequency Ultrasonic Transducers for Imaging and Therapeutic Applications
Pad-printed thick-film transducers have been shown to be an interesting alternative to lapped bulk piezoceramics, because the film is deposited with the required thickness, size, and geometry, thus avoiding any subsequent machining to achieve geometrical focusing. Their electromechanical properties are close to those of bulk ceramics with similar composition despite having a higher porosity. In this paper, padprinted high-frequency transducers based on a low-loss piezoceramic composition are designed and fabricated. High-porosity ceramic cylinders with a spherical top surface are used as the backing substrate. The transducers are characterized in view of imaging applications and their imaging capabilities are evaluated with phantoms containing spherical inclusions and in different biological tissues. In addition, the transducers are evaluated for their capability to produce high-acoustic intensities at frequencies around 20 MHz. High-intensity measurements, obtained with a calibrated hydrophone, show that transducer performance is promising for applications that would require the same device to be used for imaging and for therapy. Nevertheless, the transducer design can be improved, and simulation studies are performed to find a better compromise between low-power and high-power performance. The size, geometry, and constitutive materials of optimized configurations are proposed and their feasibility is discussed
Correspondence - Characterization of the effective performance of a high-frequency annular-array-based imaging system using anechoic-pipe phantoms
A resolution integral (RI) method based on anechoic-pipe, tissue-mimicking phantoms was used to compare the detection capabilities of high-frequency imaging systems based on a single-element transducer, a state-of-the-art, 256-element linear array or a 5-element annular array. All transducers had a central frequency of 40 MHz with similar conventionally measured axial and lateral resolutions (about 50 and 85 μm, respectively). Using the RI metric, the annular array achieved the highest performance (RI = 60), followed by the linear array (47) and the single-element transducer (24). Results showed that the RI metric could be used to efficiently quantify the effective transducer performance and compare the image quality of different systems
Palaeoproteomic phylogenetic analysis
Pleistocene Pongo teeth show substantial variation in size and morphology, fueling taxonomic debates about the paleodiversity of the genus. We investigated prominent features of the enamel-dentine-junction junction (EDJ)–phylogenetically informative internal structures–of 71 fossil Pongo lower molars from various sites by applying geometric morphometrics and conducted paleoproteomic analyses from enamel proteins to attempt to identify extinct orangutan species. Forty-three orangutan lower molars representing Pongo pygmaeus and Pongo abelii were included for comparison. The shape of the EDJ was analyzed by placing five landmarks on the tip of the main dentine horns, and 142 semilandmarks along the marginal ridges connecting the dentine horns. Paleoproteomic analyses were conducted on 15 teeth of Late Pleistocene Pongo using high-resolution tandem mass spectrometry. The geometric morphometric results show variations in EDJ shape regarding aspects of the height and position of the dentine horns and connecting ridges. Despite the issue of molar position and sample size, modern molars are distinguished from fossil counterparts by their elongated tooth outline and narrowly positioned dentine horns. Proteomic results show that neither a distinction of P. pygmaeus and P. abelii, nor a consistent allocation of fossil specimens to extant species is feasible. Based on the EDJ shape, the (late) Middle to Late Pleistocene Pongo samples from Vietnam share the same morphospace, supporting the previous allocation to P. devosi, although substantial overlap with Chinese fossils could also indicate close affinities with P. weidenreichi. The hypothesis that both species represent one chronospecies cannot be ruled out. Two fossil specimens, one from Tam Hay Marklot (Laos, Late Pleistocene), and another from Sangiran (Java, Early to Middle Pleistocene), along with some specimens within the Punung sample (Java), exhibit affinities with Pongo abelii. The Punung fossils might represent a mix of early Late Pleistocene and later specimens (terminal Pleistocene to Holocene) related to modern Pongo. The taxonomy and phylogeny of the complete Punung sample needs to be further investigated.Peer reviewe
Cross-validated classification results in frequencies based on M1–M2
Cross-validated classification results in frequencies based on M1–M2.Peer reviewe
Cross-validated classification results in percentages based on M3
Cross-validated classification results in percentages based on M3.Peer reviewe
- …
