171 research outputs found
Stem torsion in total hip replacement: CT measurements in 60 patients
Methods 60 patients requiring total hip arthroplasty were prospectively enrolled in this study. Minimally invasive THR was performed (anterior approach) in a lateral decubitus position and each patient underwent a postoperative CT examination. The position of the stem was evaluated by an independent external institution. Results Stem torsion ranged from -19 degrees retrotorsion to 33 degrees antetorsion. Normal antetorsion (i.e 10-15 degrees according to Tonnis) was present in 5 of 60 patients, so the prevalence of abnormal stem antetorsion was 92% (95% CI: 82-97). We found a stem antetorsion outside the range of 0-25 degrees in 21 of 60 hips. Women had a higher mean stem antetorsion (8.0 degrees (SD 11)) than men (1.5 degrees (SD 10)). Interpretation Postoperative stem antetorsion shows a high variability and is gender-related. We suggest precise assessment of stem antetorsion intraoperatively by means of computer navigation, preparing the femur first. In abnormal stem antetorsion, the cup position can be adjusted using a combined anteversion concept; alternatively, modular femoral components or stems with retroverted or anteverted necks ("retrostem") could be used
Heterogeneity in clinical practices for post-cardiotomy extracorporeal life support: A pilot survey from the PELS-1 multicenter study
Background: High-quality evidence for post-cardiotomy extracorporeal life support (PC-ECLS) management is lacking. This study investigated real-world PC-ECLS clinical practices. Methods: This cross-sectional, multi-institutional, international pilot survey explored center organization, anticoagulation management, left ventricular unloading, distal limb perfusion, PC-ECLS monitoring, and transfusion practices. Twenty-nine questions were distributed among 34 hospitals participating in the Post-cardiotomy Extra-Corporeal Life Support Study. Results: Of the 32 centers [16 low-volume (50%); 16 high-volume (50%)] that responded, 16 (50%) had dedicated ECLS specialists. Twenty-six centers (81.3%) reported using additional mechanical circulatory supports. Anticoagulation practices were highly heterogeneous: 24 hospitals (75%) reported using patients bleeding status as a guide, without a specific threshold in 54.2% of cases. Transfusion targets ranged from 7 to 10 g/dL. Most centers used cardiac venting on a case-by-case basis (78.1%) and regular distal limb perfusion (84.4%). Nineteen (54.9%) centers reported dedicated monitoring protocols, including daily echocardiography (87.5%), Swan-Ganz catheterization (40.6%), cerebral near-infrared spectroscopy (53.1%), and multimodal assessment of limb ischemia. Inspection of the circuit (71.9%), oxygenator pressure drop (68.8%), plasma free hemoglobin (75%), d-dimer (59.4%), lactate dehydrogenase (56.3%), and fibrinogen (46.9%) are used to diagnose hemolysis and thrombosis. Conclusions: This study shows remarkable heterogeneity in clinical practices for PC-ECLS management. More standardized protocols and better implementation of the available evidence are recommended
Blade-plate fixation for distal femoral fractures: A case-control study
AbstractBackgroundThe blade-plate is the earliest of the contemporary internal fixation devices introduced for distal femoral fractures. The recent development of dedicated, fixation devices has considerably limited its use. The objective of this study was to evaluate outcomes after blade-plate fixation and after fixation using other devices.HypothesisOutcomes after blade-plate fixation are similar to those after condylar screw-plate, distal femoral nail, or locking condylar plate fixation.Material and methodsWe reviewed outcomes after 62 patients managed with blade-plate fixation and included in a multicentre retrospective study (n=57) or a multicentre prospective study (n=5) and we compared them to outcomes after fixation using condylar screw-plates (n=82), distal femoral nail (n=219), or locking condylar plates (n=301). The four groups were comparable for age, gender distribution, occupational status, prevalence of skin wounds, patient-related factors, type of accident, and type of fracture. The evaluation relied on the clinical International Knee Society (IKS) score and on radiographs.ResultsNo significant differences existed across the four groups for operative time, blood transfusion use, complications, need for bone grafting, non-union rate, or IKS score values. The early surgical revision rate for removal of the fixation material was 4% with the blade-plate and 16% with the other three fixation devices (P=0.02). Post-operative fracture deformity was similar in the four groups with, however, a higher proportion of residual malalignment in the screw-fixation group. The final anatomic axis was 3.3±1.4° with the blade-plate versus 2.3±3.7° with the other three fixation devices. The blade-plate group had few patients with axial malalignment, and the degree of malalignment was limited to 3° of varus and 10° of valgus at the most, compared to 10° and 18° respectively, with the other three fixation devices.ConclusionDespite the now extremely limited use and teaching of blade-plate fixation, as well as the undeniable technical challenges raised by the implantation of this device, the blade-plate is a simple, strong, and inexpensive fixation method. It remains reliable for the fixation of distal femoral fractures. The disfavour into which the blade-plate is currently falling is not warranted.Level of evidenceIII, case-control study
Association between Intraventricular Position of Inflow Cannula and Clinical Outcomes in LVAD Recipients
International audience83
- …
