222 research outputs found
DNA transport by a micromachined Brownian ratchet device
We have micromachined a silicon-chip device that transports DNA with a
Brownian ratchet that rectifies the Brownian motion of microscopic particles.
Transport properties for a DNA 50mer agree with theoretical predictions, and
the DNA diffusion constant agrees with previous experiments. This type of
micromachine could provide a generic pump or separation component for DNA or
other charged species as part of a microscale lab-on-a-chip. A device with
reduced feature size could produce a size-based separation of DNA molecules,
with applications including the detection of single nucleotide polymorphisms.Comment: Latex: 8 pages, 4 figure
Brownian motion exhibiting absolute negative mobility
We consider a single Brownian particle in a spatially symmetric, periodic
system far from thermal equilibrium. This setup can be readily realized
experimentally. Upon application of an external static force F, the average
particle velocity is negative for F>0 and positive for F<0 (absolute negative
mobility).Comment: 4 pages, 3 figures, to be published in PR
Severe Aortic Stenosis and Myocardial Function: Diagnostic and Prognostic Usefulness of Ultrasonic Integrated Backscatter Analysis
Background— The aim of this study was to assess the myocardial reflectivity pattern in severe aortic valve stenosis through the use of integrated backscatter (IBS) analysis. Patients with aortic stenosis (AS) were carefully selected in the Department of Cardiology.
Methods and Results— Thirty-five subjects (AS: valve orifice ≤1 cm2; 12 female; mean age, 71.8±6.2 years) and 25 healthy subjects were studied. All subjects of the study had conventional 2D-Doppler echocardiography and IBS. Backscatter signal was sampled at the septum and posterior wall levels. Patients with AS were divided into 2 groups: 16 patients with initial signs of congestive heart failure and a depressed left ventricular systolic function (DSF) (ejection fraction [EF] range, 35% to 50%) and 19 asymptomatic patients with normal left ventricular systolic function (NSF) (EF >50%). Myocardial echo intensity (pericardium related) was significantly higher at the septum and posterior wall levels in DSF than in NSF and in control subjects. IBS variation, as an expression of variation of the signal, appeared to be significantly lower in AS with DSF than in NSF and in control subjects, at both the septum and posterior wall levels. Patients with DSF underwent aortic valve replacement, and, during surgical intervention, a septal myocardial biopsy was made for evaluation of myocardium/fibrosis ratio. Abnormally increased echo intensity was detected in left ventricular pressure overload by severe aortic stenosis and correlated with increase of myocardial collagen content (operating biopsy).
Conclusions— One year after aortic valve replacement, we observed a significant reduction of left ventricular mass, and, only if pericardial indexed IBS value (reduction of interstitial fibrosis) decreased, it was possible to observe an improvement of EF and of IBS variation
Disorder Induced Diffusive Transport In Ratchets
The effects of quenched disorder on the overdamped motion of a driven
particle on a periodic, asymmetric potential is studied. While for the
unperturbed potential the transport is due to a regular drift, the quenched
disorder induces a significant additional chaotic ``diffusive'' motion. The
spatio-temporal evolution of the statistical ensemble is well described by a
Gaussian distribution, implying a chaotic transport in the presence of quenched
disorder.Comment: 10 pages, 4 EPS figures; submitted to Phys. Rev. Letter
Research on mesophilic aerobic microorganisms and enterobacteriaceae in cultivated and commercialized agaricus bisporus
Algorithms for the mitigation of space weather threats at low latitudes, contributing to the extension of EGNOS over Africa
New basic insights on the potential of chitosan-based medical device for improving functional recovery after radical prostatectomy
- …
