1,909 research outputs found
Rotational sensitivity of the "G-Pisa" gyrolaser
G-Pisa is an experiment investigating the possibility to operate a high
sensitivity laser gyroscope with area less than for improving the
performances of the mirrors suspensions of the gravitational wave antenna
Virgo. The experimental set-up consists in a He-Ne ring laser with a 4 mirrors
square cavity. The laser is pumped by an RF discharge where the RF oscillator
includes the laser plasma in order to reach a better stability. The contrast of
the Sagnac fringes is typically above 50% and a stable regime has been reached
with the laser operating both single mode or multimode. The effect of hydrogen
contamination on the laser was also checked. A low-frequency sensitivity, below
, in the range of has been
measured.Comment: 6 pages, 6 figures, presented at the EFTF-IFCS joint conference 200
Spatial variability of switchgrass (Panicum virgatum L.) yield as related to soil parameters in a small field
The harvested biomass of switchgrass (Panicum virgatum L.) is generally much lower than its potential; this may be due to several factors including not recovering all the biomass at harvest, weed competition, pests, disease and spatial variation of soil features. The objective of this research was to quantify the yield spatial variation of switchgrass and relate it to soil parameters, in a field of about 5 ha, in 2004 and 2005. Several thematic maps of soil parameters and biomass yield were produced using GIS and geostatistical methods. Soil parameters changed consistently within very short distances and biomass yield varied from 3 to more than 20 Mg ha(-1). This remarkable variation indicates that the potential for increasing switchgrass productivity is a real prospect. Furthermore, spatial variation of yield showed similar patterns in the 2 years (r = 0.38**), and therefore a major influence of site characteristics on switchgrass yield can be assumed to occur. Significant correlations were found between biomass yield and soil N, P, moisture and pH as well as between soil parameters. Some soil parameters such as sand content showed patchy spatial distribution. Conversely, a reliable spatial dependence could not be identified for other parameters such as P. Further research is needed
A 1.82 m^2 ring laser gyroscope for nano-rotational motion sensing
We present a fully active-controlled He-Ne ring laser gyroscope, operating in
square cavity 1.35 m in side. The apparatus is designed to provide a very low
mechanical and thermal drift of the ring cavity geometry and is conceived to be
operative in two different orientations of the laser plane, in order to detect
rotations around the vertical or the horizontal direction. Since June 2010 the
system is active inside the Virgo interferometer central area with the aim of
performing high sensitivity measurements of environmental rotational noise. So
far, continuous not attempted operation of the gyroscope has been longer than
30 days. The main characteristics of the laser, the active remote-controlled
stabilization systems and the data acquisition techniques are presented. An
off-line data processing, supported by a simple model of the sensor, is shown
to improve the effective long term stability. A rotational sensitivity at the
level of ten nanoradiants per squareroot of Hz below 1 Hz, very close to the
required specification for the improvement of the Virgo suspension control
system, is demonstrated for the configuration where the laser plane is
horizontal
Prevention of Chemotherapy-Induced Anemia and Thrombocytopenia by Constant Administration of Stem Cell Factor
Purpose: Chemotherapy-induced apoptosis of immature hematopoietic cells is a major cause of anemia and thrombocytopenia in cancer patients. Although hematopoietic growth factors such as erythropoietin and colony-stimulating factors cannot prevent the occurrence of drug-induced myelosuppression, stem cell factor (SCF) has been previously shown to protect immature erythroid and megakaryocytic cells in vitro from drug-induced apoptosis. However, the effect of SCF in vivo as a single myeloprotective agent has never been elucidated.
Experimental Design: The ability of SCF to prevent the occurrence of chemotherapy-induced anemia and thrombocytopenia was tested in a mouse model of cisplatin-induced myelosuppression. To highlight the importance of maintaining a continuous antiapoptotic signal in immature hematopoietic cells, we compared two treatment schedules: in the first schedule, SCF administration was interrupted during chemotherapy treatment and resumed thereafter, whereas in the second schedule, SCF was administered without interruption for 7 days, including the day of chemotherapy treatment.
Results: The administration of SCF to cisplatin-treated mice could preserve bone marrow integrity, inhibit apoptosis of erythroid and megakaryocytic precursors, prevent chemotherapy-induced anemia, and rapidly restore normal platelet production. Treatment with SCF increased the frequency of Bcl-2/Bcl-XL\u2013 positive bone marrow erythroid cells and sustained Akt activation in megakaryocytes. Myeloprotection was observed only when SCF was administered concomitantly with cisplatin and kept constantly present during the days following chemotherapy treatment.
Conclusions: SCF treatment can prevent the occurrence of chemotherapy-induced anemia and thrombocytopenia in mice, indicating a potential use of this cytokine in the supportive therapy of cancer patients
Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium
The mirror relative motion of a suspended Fabry-Perot cavity is studied in
the frequency range 3-10 Hz. The experimental measurements presented in this
paper, have been performed at the Low Frequency Facility, a high finesse
optical cavity 1 cm long suspended to a mechanical seismic isolation system
identical to that one used in the VIRGO experiment. The measured relative
displacement power spectrum is compatible with a system at thermal equilibrium
within its environmental. In the frequency region above 3 Hz, where seismic
noise contamination is negligible, the measurement distribution is stationary
and Gaussian, as expected for a system at thermal equilibrium. Through a simple
mechanical model it is shown that: applying the fluctuation dissipation theorem
the measured power spectrum is reproduced below 90 Hz and noise induced by
external sources are below the measurement.Comment: 11 pages, 9 figures, 2 tables, to be submitte
The GINGER Project and status of the ring-laser of LNGS
A ring-laser attached to the Earth measures the absolute angular velocity of the Earth summed
to the relativistic precessions, de Sitter and Lense-Thirring. GINGER (Gyroscopes IN GEneral
Relativity) is a project aiming at measuring the LenseThirring effect with a ground based detector;
it is based on an array of ring-lasers. Comparing the Earth angular velocity measured
by IERS and the measurement done with the GINGER array, the Lense-Thirring effect can be
evaluated. Compared to the existing space experiments, GINGER provides a local measurement,
not the averaged value and it is unnecessary to model the gravitational field. It is a proposal,
but it is not far from being a reality. In fact the GrossRing G of the Geodesy Observatory of
Wettzell has a sensitivity very close to the necessary one. G ofWettzell is part of the IERS system
which provides the measure of the Length Of the DAY (LOD); G provides information on the fast
component of LOD. In the last few years, a roadmap toward GINGER has been outlined. The
experiment G-GranSasso, financed by the INFN Commission II, is developing instrumentations
and tests along the roadmap of GINGER. In this short paper the main activities of G-GranSasso
and some results will be presented. The first results of GINGERino will be reported, GINGERino
is the large ring-laser installed inside LNGS and now in the commissioning phase. Ring-lasers
provide as well important informations for geophysics, in particular the rotational seismology,
which is an emerging field of science. GINGERino is one of the three experiments of common
interest between INFN and INGV
General relativistic Sagnac formula revised
The Sagnac effect is a time or phase shift observed between two beams of
light traveling in opposite directions in a rotating interferometer. We show
that the standard description of this effect within the framework of general
relativity misses the effect of deflection of light due to rotational inertial
forces. We derive the necessary modification and demonstrate it through a
detailed analysis of the square Sagnac interferometer rotating about its
symmetry axis in Minkowski space-time. The role of the time shift in a Sagnac
interferometer in the synchronization procedure of remote clocks as well as its
analogy with the Aharanov-Bohm effect are revised.Comment: 11 pages, 3 figure
- …