21,734 research outputs found
Neuroprotective Mechanism of Lycium barbarum Polysaccharides against Hippocampal-Dependent Spatial Memory Deficits in a Rat Model of Obstructive Sleep Apnea
published_or_final_versio
SUMMERTIME TROPOSPHERIC OBSERVATIONS RELATED TO NXOY DISTRIBUTIONS AND PARTITIONING OVER ALASKA - ARCTIC BOUNDARY-LAYER EXPEDITION 3A
Sorafenib dose escalation is not uniformly associated with blood pressure elevations in normotensive patients with advanced malignancies.
Hypertension after treatment with vascular endothelial growth factor (VEGF) receptor inhibitors is associated with superior treatment outcomes for advanced cancer patients. To determine whether increased sorafenib doses cause incremental increases in blood pressure (BP), we measured 12-h ambulatory BP in 41 normotensive advanced solid tumor patients in a randomized dose-escalation study. After 7 days' treatment (400 mg b.i.d.), mean diastolic BP (DBP) increased in both study groups. After dose escalation, group A (400 mg t.i.d.) had marginally significant further increase in 12-h mean DBP (P = 0.053), but group B (600 mg b.i.d.) did not achieve statistically significant increases (P = 0.25). Within groups, individuals varied in BP response to sorafenib dose escalation, but these differences did not correlate with changes in steady-state plasma sorafenib concentrations. These findings in normotensive patients suggest BP is a complex pharmacodynamic biomarker of VEGF inhibition. Patients have intrinsic differences in sensitivity to sorafenib's BP-elevating effects
ATMOSPHERIC MEASUREMENTS OF PEROXYACETYL NITRATE AND OTHER ORGANIC NITRATES AT HIGH-LATITUDES - POSSIBLE SOURCES AND SINKS
Recommended from our members
A case study of transport of tropical marine boundary layer and lower tropospheric air masses to the northern midlatitude upper troposphere
Low-ozone (<20 ppbv) air masses were observed in the upper troposphere in northern midlatitudes over the eastern United States and the North Atlantic Ocean on several occasions in October 1997 during the NASA Subsonic Assessment, Ozone and Nitrogen Oxide Experiment (SONEX) mission. Three cases of low-ozone air masses were shown to have originated in the tropical Pacific marine boundary layer or lower troposphere and advected poleward along a warm conveyor belt during a synoptic-scale disturbance. The tropopause was elevated in the region with the low-ozone air mass. Stratospheric intrusions accompanied the disturbances. On the basis of storm track and stratospheric intrusion climatologies, such events appear to be more frequent from September through March than the rest of the year. Copyright 2000 by the American Geophysical Union
Investigation of the functional roles of host cell proteins involved in Coronavirus infection using highly specific and scalable RNA interference (RNAi) approach
Since its identification in the 1990s, the RNA interference (RNAi) pathway has proven extremely useful in elucidating the function of proteins in the context of cells and even whole organisms. In particular, this sequence-specific and powerful loss-of-function approach has greatly simplified the study of the role of host cell factors implicated in the life cycle of viruses. Here, we detail the RNAi method we have developed and used to specifically knock down the expression of ezrin, an actin binding protein that was identified by yeast two-hybrid screening to interact with the Severe Acute Respiratory Syndrome Coronavirus (SARS-CoV) spike (S) protein. This method was used to study the role of ezrin, specifically during the entry stage of SARS-CoV infection
Fuel for the Work Required: A Theoretical Framework for Carbohydrate Periodization and the Glycogen Threshold Hypothesis.
Deliberately training with reduced carbohydrate (CHO) availability to enhance endurance-training-induced metabolic adaptations of skeletal muscle (i.e. the 'train low, compete high' paradigm) is a hot topic within sport nutrition. Train-low studies involve periodically training (e.g., 30-50% of training sessions) with reduced CHO availability, where train-low models include twice per day training, fasted training, post-exercise CHO restriction and 'sleep low, train low'. When compared with high CHO availability, data suggest that augmented cell signalling (73% of 11 studies), gene expression (75% of 12 studies) and training-induced increases in oxidative enzyme activity/protein content (78% of 9 studies) associated with 'train low' are especially apparent when training sessions are commenced within a specific range of muscle glycogen concentrations. Nonetheless, such muscle adaptations do not always translate to improved exercise performance (e.g. 37 and 63% of 11 studies show improvements or no change, respectively). Herein, we present our rationale for the glycogen threshold hypothesis, a window of muscle glycogen concentrations that simultaneously permits completion of required training workloads and activation of the molecular machinery regulating training adaptations. We also present the 'fuel for the work required' paradigm (representative of an amalgamation of train-low models) whereby CHO availability is adjusted in accordance with the demands of the upcoming training session(s). In order to strategically implement train-low sessions, our challenge now is to quantify the glycogen cost of habitual training sessions (so as to inform the attainment of any potential threshold) and ensure absolute training intensity is not compromised, while also creating a metabolic milieu conducive to facilitating the endurance phenotype
A holographic system for subsea recording and analysis of plankton and other marine particles
We report here details of the design, development, initial testing and field-deployment of the HOLOMAR system for in-situ subsea holography and analysis of marine plankton and nonliving particles. HOLOMAR comprises a submersible holographic camera ("HoloCam") able to record in-line and off-axis holograms at depths down to 100 m, together with specialised reconstruction hardware ("HoloScan") linked to custom image processing and classification software. The HoloCam consists of a laser and power supply, holographic recording optics and holographic plate holders, a water-tight housing and a support frame. It utilises two basic holographic geometries, in-line and off-axis such that a wide range of species, sizes and concentrations can be recorded. After holograms have been recorded and processed they are reconstructed in full three-dimensional detail in air in a dedicated replay facility. A computer-controlled microscope, using video cameras to record the image at a given depth, is used to digitise the scene. Specially written software extracts a binarised image of an object in its true focal plane and is classified using a neural network. The HoloCam was deployed on two separate cruises in a Scottish sea loch (Loch Etive) to a depth of 100 m and over 300 holograms were recorded
Wireless monitoring of liver hemodynamics in vivo
Liver transplants have their highest technical failure rate in the first two weeks following surgery. Currently, there are limited devices for continuous, real-time monitoring of the graft. In this work, a three wavelengths system is presented that combines near-infrared spectroscopy and photoplethysmography with a processing method that can uniquely measure and separate the venous and arterial oxygen contributions. This strategy allows for the quantification of tissue oxygen consumption used to study hepatic metabolic activity and to relate it to tissue stress. The sensor is battery operated and communicates wirelessly with a data acquisition computer which provides the possibility of implantation provided sufficient miniaturization. In two in vivo porcine studies, the sensor tracked perfusion changes in hepatic tissue during vascular occlusions with a root mean square error (RMSE) of 0.135 mL/min/g of tissue. We show the possibility of using the pulsatile wave to measure the arterial oxygen saturation similar to pulse oximetry. The signal is also used to extract the venous oxygen saturation from the direct current (DC) levels. Arterial and venous oxygen saturation changes were measured with an RMSE of 2.19% and 1.39% respectively when no vascular occlusions were induced. This error increased to 2.82% and 3.83% when vascular occlusions were induced during hypoxia. These errors are similar to the resolution of a commercial oximetry catheter used as a reference. This work is the first realization of a wireless optical sensor for continuous monitoring of hepatic hemodynamics. © 2014 Akl et al
Recommended from our members
ATMOSPHERIC CHEMISTRY IN THE ARCTIC AND SUB-ARCTIC - INFLUENCE OF NATURAL FIRES, INDUSTRIAL EMISSIONS, AND STRATOSPHERIC INPUTS
- …
