176 research outputs found

    Estimates for the background of the ATHENA X-IFU instrument: the cosmic rays contribution

    Get PDF
    The background of the ATHENA X-IFU instrument is evaluated by Geant4 simulations. A new, highly detailed, mass model of the X-IFU and of its cryostat has been produced, a new model for the Galactic Cosmic Ray protons in L2 has been developed from satellite data, and a set of physics models tuned to ATHENA needs has been refined through extensive validations against experimental results. We are going to report the latest results in the estimate of the background of the X-IFU instrument, obtained after the update of all the elements of the Geant4 simulations and of the post processing software

    ATHENA Italian Management Plan

    Get PDF
    The scope of this management plan (MP) is to describe the management of the Italian team in the ATHENA space mission and to clarify roles and responsibilities within the Italian team. Objective of this document is to provide a structured and consistent approach to the Italian management of the ATHENA project to be compliant with the ESA programmatic development. This MP considers all the project management activities that are addressed by the ESA standard ECSS-M-ST-10C “Space project management” in the framework of the Italian Collaboration in the ATHENA mission. The Funding Agency (FA) responsible for the national contribution to the mission is the Italian Space Agency (ASI)

    The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector

    Get PDF
    The Cryogenic AntiCoincidence detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4-pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC demonstration model, a prototype aimed to probe the critical technologies of the detector, i.e., the suspended absorber with an active area of 1 cm2; the low energy threshold of 20 keV; and the operation connected to a 50 mK thermal bath with a power dissipation less than 40 nW. Here, we report the test performed on the first CryoAC DM sample (namely, the AC-S10 prototype), showing that it is fully compliant with its requirements

    The evaluation of the CUSP scientific performance by a GEANT4 Monte Carlo simulation

    Full text link
    The CUbesat Solar Polarimeter (CUSP) project is a CubeSat mission orbiting the Earth aimed to measure the linear polarization of solar flares in the hard X-ray band by means of a Compton scattering polarimeter. CUSP will allow to study the magnetic reconnection and particle acceleration in the flaring magnetic structures of our star. CUSP is a project in the framework of the Alcor Program of the Italian Space Agency aimed to develop new CubeSat missions. It is approved for a Phase B study. In this work, we report on the accurate simulation of the detector's response to evaluate the scientific performance. A GEANT4 Monte Carlo simulation is used to assess the physical interactions of the source photons with the detector and the passive materials. Using this approach, we implemented a detailed CUSP Mass Model. In this work, we report on the evaluation of the detector's effective area as a function of the beam energy.Comment: Proceeding of SPIE Conference "Astronomical Telescopes+ Instrumentation", Yokohama (Japan), 16-21 June 202

    The multi-physics analysis and design of CUSP, a two CubeSat constellation for Space Weather and Solar flares X-ray polarimetry

    Full text link
    The CUbesat Solar Polarimeter (CUSP) project aims to develop a constellation of two CubeSats orbiting the Earth to measure the linear polarization of solar flares in the hard X-ray band by means of a Compton scattering polarimeter on board of each satellite. CUSP will allow to study the magnetic reconnection and particle acceleration in the flaring magnetic structures. CUSP is a project approved for a Phase B study by the Italian Space Agency in the framework of the Alcor program aimed to develop CubeSat technologies and missions. In this paper we describe the a method for a multi-physical simulation analysis while analyzing some possible design optimization of the payload design solutions adopted. In particular, we report the mechanical design for each structural component, the results of static and dynamic finite element analysis, the preliminary thermo-mechanical analysis for two specific thermal cases (hot and cold orbit) and a topological optimization of the interface between the platform and the payload.Comment: Proceeding of SPIE Conference "Astronomical Telescopes+ Instrumentation", Yokohama (Japan), 16-21 June 202

    ATHENA X-IFU Demonstration Model: First Joint Operation of the Main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)

    Get PDF
    The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which work in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons

    How future surgery will benefit from SARS-COV-2-related measures: a SPIGC survey conveying the perspective of Italian surgeons

    Get PDF
    COVID-19 negatively affected surgical activity, but the potential benefits resulting from adopted measures remain unclear. The aim of this study was to evaluate the change in surgical activity and potential benefit from COVID-19 measures in perspective of Italian surgeons on behalf of SPIGC. A nationwide online survey on surgical practice before, during, and after COVID-19 pandemic was conducted in March-April 2022 (NCT:05323851). Effects of COVID-19 hospital-related measures on surgical patients' management and personal professional development across surgical specialties were explored. Data on demographics, pre-operative/peri-operative/post-operative management, and professional development were collected. Outcomes were matched with the corresponding volume. Four hundred and seventy-three respondents were included in final analysis across 14 surgical specialties. Since SARS-CoV-2 pandemic, application of telematic consultations (4.1% vs. 21.6%; p < 0.0001) and diagnostic evaluations (16.4% vs. 42.2%; p < 0.0001) increased. Elective surgical activities significantly reduced and surgeons opted more frequently for conservative management with a possible indication for elective (26.3% vs. 35.7%; p < 0.0001) or urgent (20.4% vs. 38.5%; p < 0.0001) surgery. All new COVID-related measures are perceived to be maintained in the future. Surgeons' personal education online increased from 12.6% (pre-COVID) to 86.6% (post-COVID; p < 0.0001). Online educational activities are considered a beneficial effect from COVID pandemic (56.4%). COVID-19 had a great impact on surgical specialties, with significant reduction of operation volume. However, some forced changes turned out to be benefits. Isolation measures pushed the use of telemedicine and telemetric devices for outpatient practice and favored communication for educational purposes and surgeon-patient/family communication. From the Italian surgeons' perspective, COVID-related measures will continue to influence future surgical clinical practice

    The CUbesat Solar Polarimeter (CUSP) mission overview

    Full text link
    The CUbesat Solar Polarimeter (CUSP) project is a future CubeSat mission orbiting the Earth aimed to measure the linear polarization of solar flares in the hard X-ray band, by means of a Compton scattering polarimeter. CUSP will allow us to study the magnetic reconnection and particle acceleration in the flaring magnetic structures of our star. The project is in the framework of the Italian Space Agency Alcor Program, which aims to develop new CubeSat missions. CUSP is approved for a Phase B study that will last for 12 months, starting in mid-2024. We report on the current status of the CUSP mission project as the outcome of the Phase A.Proceeding of SPIE Conference Astronomical Telescopes+ Instrumentation , Yokohama (Japan), 16-21 June 2024. arXiv admin note: substantial text overlap with arXiv:2208.0621

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin
    corecore