1,155 research outputs found
Troubling Vulnerability: Designing with LGBT Young People's Ambivalence Towards Hate Crime Reporting
HCI is increasingly working with ?vulnerable? people yet there is a danger that the label of vulnerability can alienate and stigmatize the people such work aims to support. We report our study investigating the application of interaction design to increase rates of hate crime reporting amongst Lesbian, Gay, Bisexual and Transgender young people. During design-led workshops participants expressed ambivalence towards reporting. While recognizing their exposure to hate crime they simultaneously rejected ascription as victim as implied in the act of reporting. We used visual communication design to depict the young people?s ambivalent identities and contribute insights on how these fail and succeed to account for the intersectional, fluid and emergent nature of LGBT identities through the design research process. We argue that by producing ambiguous designed texts, alongside conventional qualitative data, we ?trouble? our design research narratives as a tactic to disrupt static and reductive understandings of vulnerability within HCI
The design of a project to assess bilateral versus unilateral hearing aid fitting
Binaural hearing provides advantages over monaural in several ways, particularly in difficult listening situations. For a person with bilateral hearing loss, the bilateral fitting of hearing aids thus seems like a natural choice. However, surprisingly few studies have been reported in which the additional benefit of bilateral versus unilateral hearing aid use has been investigated based on real-life experiences. Therefore, a project has been designed to address this issue and to find tools to identify people for whom the drawbacks would outweigh the advantages of bilateral fitting. A project following this design is likely to provide reliable evidence concerning differences in benefit between unilateral and bilateral fitting of hearing aids by evaluating correlations between entrance data and outcome measures and final preferences
Potential effects of oilseed rape expressing oryzacystatin-1 (OC-1) and of purified insecticidal proteins on larvae of the solitary bee Osmia bicornis
Despite their importance as pollinators in crops and wild plants, solitary bees have not previously been included in non-target testing of insect-resistant transgenic crop plants. Larvae of many solitary bees feed almost exclusively on pollen and thus could be highly exposed to transgene products expressed in the pollen. The potential effects of pollen from oilseed rape expressing the cysteine protease inhibitor oryzacystatin-1 (OC-1) were investigated on larvae of the solitary bee Osmia bicornis (= O. rufa). Furthermore, recombinant OC-1 (rOC-1), the Bt toxin Cry1Ab and the snowdrop lectin Galanthus nivalis agglutinin (GNA) were evaluated for effects on the life history parameters of this important pollinator. Pollen provisions from transgenic OC-1 oilseed rape did not affect overall development. Similarly, high doses of rOC-1 and Cry1Ab as well as a low dose of GNA failed to cause any significant effects. However, a high dose of GNA (0.1%) in the larval diet resulted in significantly increased development time and reduced efficiency in conversion of pollen food into larval body weight. Our results suggest that OC-1 and Cry1Ab expressing transgenic crops would pose a negligible risk for O. bicornis larvae, whereas GNA expressing plants could cause detrimental effects, but only if bees were exposed to high levels of the protein. The described bioassay with bee brood is not only suitable for early tier non-target tests of transgenic plants, but also has broader applicability to other crop protection products
A survey of insecticide susceptibility in Plutella xylostella (L.) (Lepidoptera: Yponomeutidae) in the Federal District, Brazil.
The level of insecticide susceptibility of strains of Plutella xylostella (L.) from the Federal District was evaluated in 1995 and 1996. A homogeneity in acephate and phentoate susceptibility was observed in the surveyed strains. One strain, highly susceptible to Bacillus thuringiensis lost its susceptibility after 10 insecticide sprays in two generations in the field with a 36-fold increase in its LC50. Movements of the pest could have accounted for the observed results
The crystal structures of disordered crystals of adducts of diphenylmercury with bidentate ligands
Food availability and larval density affect ovarian development in Plutella xylostella (L.)(Lepidoptera: Yponomeutidae).
Assessment of myocardial microstructural dynamics by in vivo diffusion tensor cardiac magnetic resonance
Background: Cardiomyocytes are organized in microstructures termed sheetlets that reorientate during left ventricular thickening. Diffusion tensor cardiac magnetic resonance (DT-CMR) may enable noninvasive interrogation of in vivo cardiac microstructural dynamics. Dilated cardiomyopathy (DCM) is a condition of abnormal myocardium with unknown sheetlet function.
Objectives: This study sought to validate in vivo DT-CMR measures of cardiac microstructure against histology, characterize microstructural dynamics during left ventricular wall thickening, and apply the technique in hypertrophic cardiomyopathy (HCM) and DCM.
Methods: In vivo DT-CMR was acquired throughout the cardiac cycle in healthy swine, followed by in situ and ex vivo DT-CMR, then validated against histology. In vivo DT-CMR was performed in 19 control subjects, 19 DCM, and 13 HCM patients.
Results: In swine, a DT-CMR index of sheetlet reorientation (E2A) changed substantially (E2A mobility ∼46°). E2A changes correlated with wall thickness changes (in vivo r2 = 0.75; in situ r2 = 0.89), were consistently observed under all experimental conditions, and accorded closely with histological analyses in both relaxed and contracted states. The potential contribution of cyclical strain effects to in vivo E2A was ∼17%. In healthy human control subjects, E2A increased from diastole (18°) to systole (65°; p < 0.001; E2A mobility = 45°). HCM patients showed significantly greater E2A in diastole than control subjects did (48°; p < 0.001) with impaired E2A mobility (23°; p < 0.001). In DCM, E2A was similar to control subjects in diastole, but systolic values were markedly lower (40°; p < 0.001) with impaired E2A mobility (20°; p < 0.001).
Conclusions: Myocardial microstructure dynamics can be characterized by in vivo DT-CMR. Sheetlet function was abnormal in DCM with altered systolic conformation and reduced mobility, contrasting with HCM, which showed reduced mobility with altered diastolic conformation. These novel insights significantly improve understanding of contractile dysfunction at a level of noninvasive interrogation not previously available in humans
Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification--a multi-vendor study.
PURPOSE: Eddy current induced velocity offsets are of concern for accuracy in cardiovascular magnetic resonance (CMR) volume flow quantification. However, currently known theoretical aspects of eddy current behavior have not led to effective guidelines for the optimization of flow quantification sequences. This study is aimed at identifying correlations between protocol parameters and the resulting velocity error in clinical CMR flow measurements in a multi-vendor study. METHODS: Nine 1.5T scanners of three different types/vendors were studied. Measurements were performed on a large stationary phantom. Starting from a clinical breath-hold flow protocol, several protocol parameters were varied. Acquisitions were made in three clinically relevant orientations. Additionally, a time delay between the bipolar gradient and read-out, asymmetric versus symmetric velocity encoding, and gradient amplitude and slew rate were studied in adapted sequences as exploratory measurements beyond the protocol. Image analysis determined the worst-case offset for a typical great-vessel flow measurement. RESULTS: The results showed a great variation in offset behavior among scanners (standard deviation among samples of 0.3, 0.4, and 0.9 cm/s for the three different scanner types), even for small changes in the protocol. Considering the absolute values, none of the tested protocol settings consistently reduced the velocity offsets below the critical level of 0.6 cm/s neither for all three orientations nor for all three scanner types. Using multilevel linear model analysis, oblique aortic and pulmonary slices showed systematic higher offsets than the transverse aortic slices (oblique aortic 0.6 cm/s, and pulmonary 1.8 cm/s higher than transverse aortic). The exploratory measurements beyond the protocol yielded some new leads for further sequence development towards reduction of velocity offsets; however those protocols were not always compatible with the time-constraints of breath-hold imaging and flow-related artefacts. CONCLUSIONS: This study showed that with current systems there was no generic protocol which resulted into acceptable flow offset values. Protocol optimization would have to be performed on a per scanner and per protocol basis. Proper optimization might make accurate (transverse) aortic flow quantification possible for most scanners. Pulmonary flow quantification would still need further (offline) correction.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are
Motivational engagement in first-time hearing aid users: a feasibility study
Objective: To assess (1) the feasibility of incorporating the Ida Institute’s Motivation Tools into a UK audiology service, (2) the potential benefits of motivational engagement in first-time hearing aid users, and (3) predictors of hearing aid and general health outcome measures.
Design: A feasibility study using a single-centre, prospective, quasi-randomized controlled design with two arms. The Ida Institute’s Motivation Tools formed the basis for motivational engagement. Study sample: First-time hearing aid users were recruited at the initial hearing assessment appointment. The intervention arm underwent motivational engagement (M+, n = 32), and a control arm (M-, n = 36) received standard care only. Results: The M+ group showed greater self-efficacy, reduced anxiety, and greater engagement with the audiologist at assessment and fitting appointments. However, there were no significant between-group differences 10-weeks post-fitting. Hearing-related communication scores predicted anxiety, and social isolation scores predicted depression for the M+ group. Readiness to address hearing difficulties predicted hearing aid outcomes for the M- group. Hearing sensitivity was not a predictor of outcomes. Conclusions: There were some positive results from motivational engagement early in the patient journey. Future research should consider using qualitative methods to explore whether there are longer-term benefits of motivational engagement in hearing aid users
- …
