294 research outputs found

    Ultrasound-guided trans-rectal high-intensity focused ultrasound (HIFU) for advanced cervical cancer ablation is feasible: a case report.

    Get PDF
    High-intensity focused ultrasound (HIFU) is an ablative treatment undergoing assessment for the treatment of benign and malignant disease. We describe the first reported intracavitary HIFU ablation for recurrent, unresectable and symptomatic cervical cancer.A 38 year old woman receiving palliative chemotherapy for metastatic cervical adenocarcinoma was offered ablative treatment from an intracavitary trans-rectal HIFU device (Sonablate® 500). Pre-treatment symptoms included vaginal bleeding and discharge that were sufficient to impede her quality of life. No peri-procedural adverse events occurred. Symptoms resolved completely immediately post-procedure, reappeared at 7 days, increasing to pre-procedural levels by day 30.This first time experience of intracavitary cervical HIFU suggests that it is feasible for palliation of advanced cervical cancer, with no early evidence of unexpected toxicity. Ethical approval had also been granted for the use of per-vaginal access if appropriate. This route, alone or in combination with the rectal route, may provide increased accessibility in future patients with a redesigned device more suited to trans-vaginal ablations.Intracavitary HIFU is a potentially safe procedure for the treatment of cervical cancer and able to provide symptomatic improvement in the palliative setting

    The effect of tumour size on drug transport and uptake in 3-D tumour models reconstructed from magnetic resonance images

    Get PDF
    This work was partially funded by the UK Engineering and Physics Sciences Research Council (EP/I001700/1) to XYX. The funder had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.Peer reviewedPublisher PD

    Safety and treatment volumes achieved following new developments of the magnetic resonance-guided focused ultrasound system in the treatment of uterine fibroids: a cohort study.

    Get PDF
    BACKGROUND: This research investigates whether modifications to the magnetic resonance-guided focused ultrasound ablation of uterine fibroid (MRgFUS) system used resulted in improved treatment volumes of uterine fibroids, while maintaining safety. METHODS: This study is a prospective cohort analysis of 34 women undergoing the ExAblate 2100 MRgFUS treatment for their uterine fibroids. RESULTS: The percentage of non-perfused volume (NPV) achieved with the ExAblate 2100 system was 54.92% compared with 50.49 % with the ExAblate 2000 system over the preceding year (p = 0.543). The ExAblate 2100 system resulted in a greater NPV in hyper-intense fibroids compared with the ExAblate 200 system (43.20% versus 36.33%, p = 0.005). There have been no recorded hospital admissions, no skins burns, and no reported major adverse events since the introduction of this new system. CONCLUSION: Overall, the new system has thus far shown an encouraging safety record and an improvement in non-perfused volumes achieved, especially in hyper-intense fibroids

    Focused Ultrasound Induced Hyperthermia Accelerates and Increases the Uptake of anti-Her2 Antibodies in a Xenograft Model

    Get PDF
    AbstractImage guided drug delivery has gained significant attention during the last few years. Labelling nanoparticles or macromolecules and monitoring their fate in the body provides information that can be used to modulate their biodistribution and improve their pharmacokinetics. In this study we label antibodies and monitor their distribution in the tumours post intravenous injection. Using Focused Ultrasound (FUS, a non-invasive method of hyperthermia) we increase the tumour temperature to 42 °C for a short period of time (3–5 min) and we observe an increased accumulation of labelled antibody. Repetition of focused ultrasound induced hyperthermic treatment increased still further the accumulation of the antibodies in the tumour. This treatment also augmented the accumulation of other macromolecules non-specific in the tumour, such as IgG and albumin. These effects may be used to enhance the therapeutic efficiency of antibodies and/or targeted nanoparticles

    Ethnicity and prediction of cardiovascular disease: performance of QRISK2 and Framingham scores in a U.K. tri-ethnic prospective cohort study (SABRE--Southall And Brent REvisited).

    Get PDF
    OBJECTIVE: To evaluate QRISK2 and Framingham cardiovascular disease (CVD) risk scores in a tri-ethnic U.K. population. DESIGN: Cohort study. SETTING: West London. PARTICIPANTS: Randomly selected from primary care lists. Follow-up data were available for 87% of traced participants, comprising 1866 white Europeans, 1377 South Asians, and 578 African Caribbeans, aged 40-69 years at baseline (1998-1991). MAIN OUTCOME MEASURES: First CVD events: myocardial infarction, coronary revascularisation, angina, transient ischaemic attack or stroke reported by participant, primary care or hospital records or death certificate. RESULTS: During follow-up, 387 CVD events occurred in men (14%) and 78 in women (8%). Both scores underestimated risk in European and South Asian women (ratio of predicted to observed risk: European women: QRISK2: 0.73, Framingham: 0.73; South Asian women: QRISK2: 0.52, Framingham: 0.43). In African Caribbeans, Framingham over-predicted in men and women and QRISK2 over-predicted in women. Framingham classified 28% of participants as high risk, predicting 54% of all such events. QRISK2 classified 19% as high risk, predicting 42% of all such events. Both scores performed poorly in identifying high risk African Caribbeans; QRISK2 and Framingham identified as high risk only 10% and 24% of those who experienced events. CONCLUSIONS: Neither score performed consistently well in all ethnic groups. Further validation of QRISK2 in other multi-ethnic datasets, and better methods for identifying high risk African Caribbeans and South Asian women, are required

    MRI-Guided Focused Ultrasound as a New Method of Drug Delivery

    Get PDF
    Ultrasound-mediated drug delivery under the guidance of an imaging modality can improve drug disposition and achieve site-specific drug delivery. The term focal drug delivery has been introduced to describe the focal targeting of drugs in tissues with the help of imaging and focused ultrasound. Focal drug delivery aims to improve the therapeutic profile of drugs by improving their specificity and their permeation in defined areas. Focused-ultrasound- (FUS-) mediated drug delivery has been applied with various molecules to improve their local distribution in tissues. FUS is applied with the aid of microbubbles to enhance the permeability of bioactive molecules across BBB and improve drug distribution in the brain. Recently, FUS has been utilised in combination with MRI-labelled liposomes that respond to temperature increase. This strategy aims to “activate” nanoparticles to release their cargo locally when triggered by hyperthermia induced by FUS. MRI-guided FUS drug delivery provides the opportunity to improve drug bioavailability locally and therefore improve the therapeutic profiles of drugs. This drug delivery strategy can be directly translated to clinic as MRg FUS is a promising clinically therapeutic approach. However, more basic research is required to understand the physiological mechanism of FUS-enhanced drug delivery.</jats:p

    Tremor assessment scales before, during and after MRgFUS for essential tremor–results, recommendations and implications

    Get PDF
    Background: neurosurgical interventions such as MR-guided focused ultrasound (MRgFUS) are increasingly deployed for treatment of essential tremor. Objective: to make recommendations for monitoring treatment effects during and after MRgFUS based on our investigation of correlations between different scales of tremor severity. Methods: twenty-five clinical assessments were collected from thirteen patients before and after unilateral MRgFUS sequential lesioning of the thalamus and posterior subthalamic area for alleviating essential tremor. Scales included Bain Findley Spirography (BFS), Clinical Rating Scale for Tremor (CRST), Upper Extremity Total Tremor Score (UETTS) and Quality of Life of Essential Tremor (QUEST), and were documented at baseline, while lying in the scanner with stereotactic frame attached (BFS), and at 24-month follow-up. Results: the four different scales of tremor severity all correlated significantly. BFS and CRST showed a strong correlation of 0.833 (p &lt; 0.001). BFS, UETTS and CRST correlated moderately with QUEST (ρ = 0.575–0.721, p &lt; 0.001). BFS and UETTS correlated significantly with all CRST subparts, with the strongest correlation between UETTS and CRST part C (ρ = 0.831, p &lt; 0.001). Moreover, BFS drawn sitting upright in an outpatient setting correlated with spirals drawn in a supine position on the scanner bed with the stereotactic frame attached. Conclusion: we recommend a combination of BFS &amp; UETTS for intraoperative assessment of awake essential tremor patients and BFS &amp; QUEST for pre-operative and follow-up assessments, as these scale sets are quick and simple to collect and provide meaningful information whilst meeting the practical constraints of intraoperative assessment.</p
    corecore