458 research outputs found

    Serum IgG antibodies from pregnant women reacting to mimotopes of simian virus 40 large T antigen, the viral oncoprotein

    Get PDF
    Simian virus 40 (SV40) large T antigen (LT) coding sequences were revealed in different human samples, whereas SV40 antibodies (Ab) were detected in human sera of cancer patients and healthy individuals, although with a lower prevalence. Previous studies carried out by the neutralization assay gave a SV40 seroprevalence, in the general population, up to 8%, although higher rates, 12%, were detected in kidney transplant children, in a group of HIV-positive patients, and in healthy females. In this study, serum samples from pregnant women, together with those from non-pregnant women, were analyzed to check the prevalence of IgG Ab reacting to SV40 LT antigens. Serum samples were collected from pregnant and non-pregnant women, with the same mean age. Women were in the range of 15-48 years old. Samples were assayed by an indirect ELISA employing specific SV40 LT mimotopes as antigens, whereas functional analysis was performed by neutralization of the viral infectivity in cell cultures. As a control, sera were analyzed for Ab against BK polyomavirus (BKPyV), which is a human polyomavirus homologous to SV40. Statistical analyses employed chi-square with Yates' correction, and Student's t tests. Indirect ELISAs indicated that pregnant women tested SV40 LT-positive with a prevalence of 17% (23/134), whereas non-pregnant women had a prevalence of 20% (36/180) (P > 0.05). Ab against BKPyV were detected with a prevalence of 80% in pregnant women and with a prevalence of 78% in non-pregnant women. These data indicate that SV40 infects at a low prevalence pregnant women. We may speculate that SV40, or a close human polyomavirus still undetected, could be transmitted from mother to fetus

    Parachute emergency landing simulation and enhanced composite material characterization for General Aviation aircraft

    Get PDF
    General Aviation (GA) aircraft crashworthiness of the vehicle when it hits the ground after the parachute deployment is an important issue. The current dynamic emergency landing regulation (CS 23.562) defines the maximum human tolerant accelerations under both vertical and horizontal directions. This article aims to compare two different aircraft configurations: metal low-wing and composite high-wing ones. Both are two-seats and single-engine GA aircraft. The purpose of the analysis is to check whether the seats and restraint systems met human injury tolerance standards and to determine the possible impact on passengers in the cabin space due to shock loads. Finite element analysis of the fuselage sections for both configurations is performed using the commercial LS-Dyna solver. An extensive campaign of experimental tests has been performed on the composite samples for tuning and validating the model and to find the transition from an undamaged up to totally collapsed sample. The material of the composite fuselage has been characterized through experimental tests. The adopted material model has been refined to match with the performed experimental analysis, allowing high-fidelity modeling. A parametric analysis has been performed to determine the optimal impact angle in terms of lumbar injuries and loads transmitted by the seat belt due to aircraft contact with the ground, thereby increasing the level of safety. The investigations carried out may be an important indicator of the design of the parachute system

    Fogli 609-596, Termini Imerese-Capo Plaia

    Get PDF
    Il Servizio Geologico Nazionale ha unificato i Fogli 609 "Termini Imerese" e 596 "Capo Plaia" in un unico Foglio denominato 609/596 "Termini Imerese-Capo Plaia" allo scopo di uniformare i rilievi e raccoglierne la descrizione in un unico volume delle Note Illustrative. Il Foglio 609/596 "Termini Imerese-Capo Plaia" della Carta Geologica d’Italia in scala 1:50.000 è stato realizzato nell’ambito del Progetto CARG con i fondi della Legge 67/88 - Legge 226/99 con una convenzione tra Servizio Geologico Nazionale ora ISPRA) e Regione Siciliana. Le aree ricadono interamente nella Provincia di Palermo, comprendono la fascia marina del Golfo di Termini Imerese fino al promontorio di Capo Plaia, la regione dei Monti di Termini Imerese e Trabia ad ovest e il settore occidentale del gruppo montuoso delle Madonie ad est. Tra questi rilievi si sviluppa un’ampio settore collinare inciso dai fiumi Torto e Imera settentrionale (o Fiume Grande)

    Optical behaviors, surface treatment, adhesion, and clinical indications of zirconia-reinforced lithium silicate (ZLS): A narrative review

    Get PDF
    Objectives: The present narrative review was focused on the optical properties, surface treatment, adhesion, and clinical indications of zirconia-reinforced lithium silicate ceramics (ZLS) for Computer-aided design / Computer-aided manufacturing (CAD/CAM) technologies. Data/sources: A literature search was performed by 3 calibrated independent researchers on PubMed, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The criteria for inclusion were: 1) papers addressing at least one of the following variables about ZLS: optical properties, surface treatment, adhesion, and clinical indications; 2) in vitro, in silico, or in vivo studies; 3) case reports; 4) systematic reviews. The exclusion criteria were: 1) animal studies; 2) non-dental studies; 3) studies only focusing on ZLS used in the heat-pressed process. Study selection: 98 records among in vitro studies and case reports were included. Conclusions: Despite the promising microstructure characteristics of ZLS, increased translucency compared to lithium disilicate ceramics (LS2) was not proven, but acceptable color changes and stability were reported. Mechanical polishing was the most effective method to reduce surface roughness. Moreover, machinability and handling of ZLS resulted harder than LS2. Conventional acid etching procedures seemed effective in conditioning ZLS surface, but no protocol has been established yet. Besides, silane-coupling and dual-curing resin cements were recommended. Clinical significance: ZLSs can be used for anterior and posterior fixed single-unit CAD/CAM restorations onto both natural teeth and implants, but do not seem to represent a viable treatment option for endocrowns onto posterior teeth or fixed dental prostheses

    A Review on Risk Management of Coronavirus Disease 19 (COVID-19) Infection in Dental Practice: Focus on Prosthodontics and All-Ceramic Materials.

    Get PDF
    Background: A novel β-coronavirus infection (COVID-19) was first detected in Wuhan city, spreading rapidly to other countries and leading to a pandemic. Dental professionals and patients are exposed to a high risk of COVID-19 infection, particularly in the prosthodontic practice, because of the bio-aerosol produced during teeth preparation with dental handpieces and the strict contact with oral fluids during impression making. This paper aimed to provide an overview to limit the risk of transmission of COVID-19 infections during prosthetic procedures in dental offices. Methods: An electronic search was conducted on the electronic databases of PubMed/Medline, Google Scholar, Embase, Scopus, Dynamed, and Open Grey with the following queries: (COVID-19) AND/OR (SARS-CoV-2) AND/OR (Coronavirus) AND/OR (contaminated surface) AND/OR (cross-infection) AND/OR (Prosthodontics) AND/OR (dental ceramic) AND/OR (glass-ceramic). A manual search was performed as well. Results: From the 1023 collected records, 32 papers were included. Conclusions: Dental offices are at high risk of spreading SARS-CoV-2 infection due to the close contact with patients and continuous exposure to saliva during dental procedures. Therefore, pre-check triages via telephone, decontamination, the disinfection of impressions, the sterilization of scanner tips, and the use of specific personal protective equipment, dental high-speed handpieces with dedicated anti-retraction valves, and effective mouthwashes are strongly recommended

    Trueness and precision of an intraoral scanner on abutments with subgingival vertical margins: An in vitro study

    Get PDF
    Objectives: This study aimed to evaluate the accuracy of an intraoral scanner (IOS - Medit i700) on tooth abutments with vertical preparations at 2 depths below the free gingival margin, and to determine if the IOS can reproduce the area beyond the finish surface of the tested preparation geometry. Methods: Two abutments for a maxillary first molar were designed by means of CAD software, with vertical preparations set at 1 and 2 mm below the gingiva. These abutments were subsequently printed in resin and placed on a reference model. The reference files consisted of scans made using a metrological machine on these abutments. Ten scans were made with the tested IOS on each sample, resulting in two study groups. The scans from the experimental groups were labeled "V-1′′ for vertical preparation at 1 mm below the gingival margin and "V-2′′ for 2 mm below. The analysis of these scans was performed using Geomagic Control X (3D SYSTEMS) to assess their trueness and precision in μm. Descriptive statistics with a 95 % confidence interval were employed, alongside independent sample tests, to ascertain any differences between the groups (α=0.05). Results: Statistically significant differences were not found both for trueness (p=.104) and precision (p=.409), between the tested geometries. The mean values for trueness were V-1 = 37.5[31.4-43.6]; V-2 = 32.6[30.6-34.6]. About the precision, the mean values were V-1 = 20.5[8.4-32.5]; V-2 = 18.4[8.2-28.5]. In both the study groups, it was possible to detect the surface beyond the finish area. Conclusions: Within the limitations of this study, vertical preparation design allows for registration of the tooth anatomy beyond the finish area with IOS. Moreover, the mean accuracy values were clinically acceptable at both 1 and 2 mm below the gingival margin

    The Effect of Spacer Treatment of Infected Hip and Knee Arthroplasties on Patients’ Mental Health: A Narrative Review of the Literature

    Get PDF
    Background: The gold standard treatment for periprosthetic joint infections is the two-stage revision that includes the spacer placement before definitive reimplantation. The management of PJI affects patients' joint function and, subsequently, their mental health. Even though significant advances have been achieved, little to no attention has been paid to the psychological implications. So, based on standardized patient-reported outcome measures (PROMs), this study aimed to clarify the effect of spacer treatment of infected hip and knee arthroplasties on patients' mental health. Methods: We performed research on the literature on PJIs in the English language using the MEDLINE database with the search strings "spacer" OR "spacers" AND "hip" OR "knee" AND "SF-12" OR "SF-36" OR "EQ-5" OR "mental" OR "depression" OR "anxiety." The reference lists of selected articles were also hand-searched for any additional articles. Results: A total of 973 published papers were extracted, and 9 papers were finally included. A total of 384 patients who underwent spacer placement for PJI were identified. Of these 384 patients, 54% were female. The mean age ranged from 62 to 78.2 years. Of the11 papers identified for this review, 4 analyzed only hip spacers, including 119 patients; 4 only knee spacers, evaluating 153 patients; while a single study included 112 patients for both joints. Conclusions: Patients with the spacer are living in a state of mental upset, albeit better than the preoperative state. Clinical improvement with the review is not assured. The alteration of mental state turns out not to be transient for all the patients

    Influence of Different Palatal Morphologies on the Accuracy of Intraoral Scanning of the Edentulous Maxilla : A Three-Dimensional Analysis

    Get PDF
    PURPOSE This study investigated the influence of different palatal morphologies on the accuracy of intraoral scanning (TRIOS 4) of edentulous maxillae. METHODS Six typodonts were fabricated for different palatal morphologies with flat (F), medium (M), and deep (D) palates, with palatal wrinkles (W), or smooth palates (S), resulting in six groups: WF, WM, WD and SF, SM, SD. Ten scans were performed for each group; standard tessellation language files obtained were imported into a software to measure trueness and precision in micrometer. Trueness was calculated as the mean of the standard deviation values obtained by superimposing each scan onto the reference scan. Precision was achieved by overlapping each scan with that with the best trueness in the group. Descriptive and post-hoc analyses were conducted. RESULTS The mean values for trueness were as follows: WM=48.7±4.7, WD=161.7±18.4, WF=85.9±16, SM=48.1±2.4, SD=349.9±8.8, and SF=349.1±25.5. The precision values were as follows: WM=46.7±7.3, WD=46.9±9, WF=48.9±6.7, SM=46±2.7, SD=105.9±17.4, SF=72.6±10.8. Significant differences were observed for trueness between SM and SD (P < 0.001), SM and SF (P < 0.001), and WF and SF (P = 0.003); whereas for precision, significant differences were reported between WD and SD (P = 0.015). Regarding trueness and precision, no difference was found between WM and SM (P = 1.0). CONCLUSIONS Medium palatal depth showed the best accuracy. The mean accuracy values were within the clinical acceptability thresholds for all palatal morphologies. The presence of rugae improved the precision of deeper palates and the trueness of flat palates. No differences were observed in the medium palates with or without rugae
    corecore