770 research outputs found
Strategy for discovering a low-mass Higgs boson at the Fermilab Tevatron
We have studied the potential of the CDF and DZero experiments to discover a
low-mass Standard Model Higgs boson, during Run II, via the processes
-> WH -> , -> ZH ->
and -> ZH ->. We
show that a multivariate analysis using neural networks, that exploits all the
information contained within a set of event variables, leads to a significant
reduction, with respect to {\em any} equivalent conventional analysis, in the
integrated luminosity required to find a Standard Model Higgs boson in the mass
range 90 GeV/c**2 < M_H < 130 GeV/c**2. The luminosity reduction is sufficient
to bring the discovery of the Higgs boson within reach of the Tevatron
experiments, given the anticipated integrated luminosities of Run II, whose
scope has recently been expanded.Comment: 26 pages, 8 figures, 7 tables, to appear in Physical Review D, Minor
fixes and revision
Recommended from our members
Shape of the posterior vitreous chamber in human emmetropia and myopia
PURPOSE: To compare posterior vitreous chamber shape in myopia to that in emmetropia. METHODS: Both eyes of 55 adult subjects were studied, 27 with emmetropia (mean spherical error [MSE] ≥ -0.55; <+0.75 D; mean +0.09 ± 0.36 D) and 28 with myopia (MSE -5.87 ± 2.31 D). Cycloplegic refraction was measured with a Shin Nippon autorefractor and anterior chamber depth and axial length with a Zeiss IOLMaster. Posterior vitreous chamber shapes were determined from T2-weighted magnetic resonance imaging (3.0-T) using procedures previously reported by our laboratory. Three-dimensional surface model coordinates were assigned to nasal, temporal, superior, and inferior quadrants and plotted in two dimensions to illustrate the composite shape of respective quadrants posterior to the second nodal point. Spherical analogues of chamber shape were constructed to compare relative sphericity between refractive groups and quadrants. RESULTS: Differences in shape occurred in the region posterior to points of maximum globe width and were thus in general accord with an equatorial model of myopic expansion. Shape in emmetropia is categorized distinctly as that of an oblate ellipse and in myopia as an oblate ellipse of significantly less degree such that it approximates to a sphere. There was concordance between shape and retinotopic projection of respective quadrants into right, left, superior, and inferior visual fields. CONCLUSIONS: Prolate ellipse posterior chamber shapes were rarely found in myopia, and we propose that spherical shape in myopia may constitute a biomechanical limitation on further axial elongation. Synchronization of quadrant shapes with retinotopic projection suggests that binocular growth is coordinated by processes that operate beyond the optic chiasm
Measurement of Scleral Thickness in Humans Using Anterior Segment Optical Coherent Tomography
Anterior segment optical coherent tomography (AS-OCT, Visante; Zeiss) is used to examine meridional variation in anterior scleral thickness (AST) and its association with refractive error, ethnicity and gender. Scleral cross-sections of 74 individuals (28 males; 46 females; aged between 18-40 years (27.7±5.3)) were sampled twice in random order in 8 meridians: [superior (S), inferior (I), nasal (N), temporal (T), superior-temporal (ST), superior-nasal (SN), inferior-temporal (IT) and inferior-nasal (IN)]. AST was measured in 1mm anterior-toposterior increments (designated the A-P distance) from the scleral spur (SS) over a 6mm distance. Axial length and refractive error were measured with a Zeiss IOLMaster biometer and an open-view binocular Shin-Nippon autorefractor. Intra- And inter-observer variability of AST was assessed for each of the 8 meridians. Mixed repeated measures ANOVAs tested meridional and A-P distance differences in AST with refractive error, gender and ethnicity. Only right eye data were analysed. AST (mean±SD) across all meridians and A-P distances was 725±46μm. Meridian SN was the thinnest (662±57μm) and I the thickest (806 ±60μm). Significant differences were found between all meridians (p<0.001), except S:ST, IT:IN, IT:N and IN:N. Significant differences between A-P distances were found except between SS and 6 mm and between 2 and 4mm. AST measurements at 1mm (682±48 μm) were the thinnest and at 6mm (818±49 μm) the thickest (p<0.001); a significant interaction occurred between meridians and A-P distances (p<0.001). AST was significantly greater (p<0.001) in male subjects but no significant differences were found between refractive error or ethnicity. Significant variations in AST occur with regard to meridian and distance from the SS and may have utility in selecting optimum sites for pharmaceutical or surgical intervention
Recommended from our members
The Effects of Severe Myopia on the Properties of Sampling Units in Peripheral Retina
SIGNIFICANCE: Poor peripheral visual acuity in myopia may reflect, in part, photoreceptor misalignment with the exit pupil of the eye. We speculate that if such misalignment causes sufficient visual deprivation and/or disrupts retinal feedback processes, it may influence eye growth itself. PURPOSE: It is known that myopic eyes have a reduced peripheral resolution acuity relative to emmetropic eyes, though it remains unclear how mechanical stretching of the retina in myopia impacts on peripheral visual performance. Our aim was to determine how retinal stretching affects the properties of sampling units in peripheral vision. METHODS: Three-dimensional magnetic resonance imaging provided a depiction in vivo of ocular shape, allowing the inter-eye ratio of retinal image surface areas and the relative alignment of surfaces to be determined in our observer, who was unique in having severe myopia in the right eye (~21 D) but only modest myopia in the left (~3 D). Visual performance was assessed for the detection and direction discrimination of drifting sinusoids positioned 40° in the temporal retina. Applying the sampling theorem to our measures, we estimated the density and cut-off frequency of the underlying sampling units. RESULTS: The retinal image surface area of the right eye was 40% larger than that of the left and was rotated 8.9° anticlockwise relative to the left eye's image surface. In agreement with a linear stretch model of myopia, the sampling density of the right eye was reduced by approximately the same ratio as that predicted from the inter-eye MRI data, namely, 1.18. However, the cut-off frequency (cycles/mm) of the right eye was approximately half that of the left, a reduction that cannot be explained solely by a linear areal expansion of retinal sampling units. CONCLUSIONS: Poor peripheral acuity in severe myopia may be caused, at least in part, by receptoral misalignment with the exit pupil
Using public engagement and consultation to inform the development of ageing-and dementia-friendly pharmacies – Innovative practice
This study explored public perceptions about the importance of, and how to create, ageing- and dementia-friendly pharmacists and pharmacies. In September 2016, four focus groups (45 minutes each) were conducted with 16 participants who represented organisations, groups or forums working with and/or for older people and people with dementia in Greater London. Discussions were recorded via handwritten notes and thematically analysed. Participants confirmed the importance of pharmacists and pharmacies being ageing- and dementia-friendly and described variability in whether this is currently the case. Suggested strategies for improvement included targeting communication, pharmacist leadership and shop layout
Effect of Vorapaxar Alone and in Combination with Aspirin on Bleeding Time and Platelet Aggregation in Healthy Adult Subjects.
The effect of the protease-activated receptor-1 (PAR-1) antagonist vorapaxar on human bleeding time is not known. This was a randomized, two-period, open-label trial in healthy men (n = 31) and women (n = 5). In period 1, subjects received 81 mg aspirin q.d. or a vorapaxar regimen achieving steady-state plasma concentrations equivalent to chronic 2.5 mg q.d. doses, for 7 days. In period 2, each group added 7 days of the therapy alternate to that of period 1 without washout. Bleeding time and platelet aggregation using arachidonic acid, ADP, and TRAP agonists were assessed. Bleeding time geometric mean ratio (90% CI) for vorapaxar/baseline was 1.01 (0.88-1.15), aspirin/baseline was 1.32 (1.15-1.51), vorapaxar + aspirin/vorapaxar was 1.47 (1.26-1.70), and vorapaxar + aspirin/aspirin was 1.12 (0.96-1.30). Unlike aspirin, vorapaxar did not prolong bleeding time compared with baseline. Bleeding time following administration of vorapaxar with aspirin was similar to that following aspirin alone
Direct Search for Charged Higgs Bosons in Decays of Top Quarks
We present a search for charged Higgs bosons in decays of pair-produced top
quarks in pbar p collisions at sqrt(s) = 1.8 TeV using 62.2 pb^-1 of data
recorded by the D0 detector at the Fermilab Tevatron collider. No evidence is
found for signal, and we exclude at 95% confidence most regions of the (M
higgs, tan beta) parameter space where the decay t->H b has a branching
fraction greater than 0.36 and B(H -> tau nu) is large.Comment: 11 pages, 4 figures, submitted to Phys. Rev. Let
Search for Electroweak Production of Single Top Quarks in ppbar Collisions
We present a search for electroweak production of single top quarks in the
electron+jets and muon+jets decay channels. The measurements use ~90 pb^-1 of
data from Run 1 of the Fermilab Tevatron collider, collected at 1.8 TeV with
the DZero detector between 1992 and 1995. We use events that include a tagging
muon, implying the presence of a b jet, to set an upper limit at the 95%
confidence level on the cross section for the s-channel process ppbar->tb+X of
39 pb. The upper limit for the t-channel process ppbar->tqb+X is 58 pb.Comment: 11 pages, 2 figures. This is the published versio
Ratio of the Isolated Photon Cross Sections at \sqrt{s} = 630 and 1800 GeV
The inclusive cross section for production of isolated photons has been
measured in \pbarp collisions at GeV with the \D0 detector at
the Fermilab Tevatron Collider. The photons span a transverse energy ()
range from 7-49 GeV and have pseudorapidity . This measurement is
combined with to previous \D0 result at GeV to form a ratio
of the cross sections. Comparison of next-to-leading order QCD with the
measured cross section at 630 GeV and ratio of cross sections show satisfactory
agreement in most of the range.Comment: 7 pages. Published in Phys. Rev. Lett. 87, 251805, (2001
- …
