546 research outputs found

    In vivo and in vitro permeability of one-step self-etch adhesives

    Get PDF
    Adhesive dentistry should effectively restore the peripheral seal of dentin after enamel removal. We hypothesize that non-rinsing, simplified, one-step self-etch adhesives are effective for minimizing dentin permeability after tooth preparation procedures. Crown preparations in vital human teeth were sealed with Adper Prompt, Xeno III, iBond, or One-Up Bond F. Epoxy resin replicas were produced from polyvinyl siloxane impressions for SEM examination. Dentin surfaces from extracted human teeth were bonded with these adhesives and connected to a fluid-transport model for permeability measurements and TEM examination. Dentinal fluid droplets were observed from adhesive surfaces in resin replicas of in vivo specimens. In vitro fluid conductance of dentin bonded with one-step self-etch adhesives was either similar to or greater than that of smear-layer-covered dentin. TEM revealed water trees within the adhesives that facilitate water movement across the polymerized, highly permeable adhesives. Both in vitro and in vivo results did not support the proposed hypothesis.published_or_final_versio

    Solvent and water retention in dental adhesive films after evaporation

    Get PDF
    published_or_final_versio

    Solvent and water retention in dental adhesive blends after evaporation

    Get PDF
    This study examined the extent of organic solvent and water retention in comonomer blends with different hydrophilicity (Hoy's solubility parameter for hydrogen bonding, δh) after solvent evaporation, and the extent of tracer penetration in polymerised films prepared from these resins. For each comonomer blend, adhesive/solvent mixtures were prepared by addition of (1) 50 wt% acetone, (2) 50 wt% ethanol, (3) 30 wt% acetone and 20 wt% water and (4) 30 wt% ethanol and 20 wt% water. The mixtures were placed in glass wells and evaporated for 30-60 s for acetone-based resins, and 60-120 s for ethanol-based resins. The weight of the comonomer mixtures was measured before and after solvent evaporation. Resin films were prepared for transmission electron microscopy (TEM) after immersion in ammonical silver nitrate. The percentages of solvent and water retained in the comonomer mixtures, and between the acetone and ethanol groups were measured gravimetrically and were statistically compared. In comonomer-organic solvent mixtures, the percentage of solvent retained in acetone and ethanol-based mixtures increased significantly with hydrophilicity of the comonomer blends (P<0.05). In resin-organic solvent-water mixtures, significantly more solvent and water were retained in the ethanol-based mixtures (P<0.0001), when compared to acetone-based mixtures after 60 s of air-drying. TEM revealed residual water being trapped as droplets in resin films containing acetone and water. Water-filled channels were seen along the film periphery of all groups and throughout the entire resin films containing ethanol and water. The addition of water to comonomer-ethanol mixtures results in increased retention of both ethanol and water because both solvents can hydrogen bond to the monomers. © 2005 Elsevier Ltd. All rights reserved.postprin

    The Mask Fitter, a Simple Method to Improve Medical Face Mask Adaptation Using a Customized 3D-Printed Frame during COVID-19: A Survey on Users’ Acceptability in Clinical Dentistry

    Get PDF
    Featured Application: The paper shows the procedure for producing a customized low-cost “Mask Fitter” made with a tablet-based 3D-face-scan and 3D-printing that could improve the sealing of FFP2 respirators. COVID-19 has deeply impacted clinical strategies in dentistry and the use of surgical masks and respirators has become critical. They should adapt to the person’s facial anatomy, but this is not always easy to achieve. Bellus3D Company proposed to apply their face scan software, used with selected smartphones and tablets, to design and 3D-print a bespoke “Mask Fitter” to improve the sealing of surgical masks and respirators. Twenty dental staff participants were face scanned and a Mask Fitter for FFP2 respirators was designed and 3D-printed. Participants were asked to wear their Mask Fitter over one week and then completed a survey. Questions were asked about wearing comfort, sealing confidence, glasses or loupes fogging, both with and without the Mask Fitter. Dental staff gave positive feedback, with levels of comfort during daily use reported as similar with and without the Mask Fitter; and a higher confidence in achieving a proper seal, ranging from a 10% confidence rating of a proper seal without the Mask Fitter to 75% with the Mask Fitter. Moreover, fogging problems decreased considerably. The tested Mask Fitter device could represent an easy and low-cost procedure to improve the facial adaptation of the FFP2 respirator

    Conventional dual-cure versus self-adhesive resin cements in dentin bond integrity

    Get PDF
    During post preparation, the root canal is exposed to the oral cavity, and endodontic treatment may fail because of coronal leakage, bacterial infection and sealing inability of the luting cement. OBJECTIVE: this study quantified the interfacial continuity produced with conventional dual-cure and self-adhesive resin cements in the cervical (C), medium (M) and apical (A) thirds of the root. MATERIAL AND METHODS: Forty single-rooted human teeth were restored using Reforpost # 01 conical glass-fiber posts and different materials (N=10 per group): group AC=Adper&#8482; ScotchBond&#8482; Multi-purpose Plus + AllCem; group ARC=Adper&#8482; ScotchBond&#8482; Multi-purpose Plus + RelyX ARC; group U100=RelyX U100; and group MXC=Maxcem Elite. After being kept in 100% humidity at 37°C for 72 hours, the samples were sectioned parallel to their longitudinal axis and positive epoxy resin replicas were made. The scanning electron micrographs of each third section of the teeth were combined using Image Analyst software and measured with AutoCAD-2002. We obtained percentage values of the interfacial continuity. RESULTS: Interfacial continuity was similar in the apical, medium and cervical thirds of the roots within the groups (Friedman test, p>0.05). Comparison of the different cements in a same root third showed that interfacial continuity was lower in MXC (C=45.5%; M=48.5%; A=47.3%) than in AC (C=85.9%, M=81.8% and A=76.0%), ARC (C=83.8%, M=82.4% and A=75.0%) and U100 (C=84.1%, M=82.4% and A=77.3%) (Kruskal-Wallis test, p<0.05). CONCLUSIONS: Allcem, Rely X ARC and U100 provide the best cementation; cementation was similar among root portions; in practical terms, U100 is the best resin because it combines good cementation and easy application and none of the cements provides complete interfacial continuity

    Influence of Modeling Liquids and Universal Adhesives Used as Lubricants on Color Stability and Translucency of Resin-Based Composites

    Get PDF
    The use of lubricants during restorative procedures is a clinically common practice to alleviate the stickiness of resin-based composite (RBCs) materials and to improve its handling. This study evaluated the effects of three modeling liquids (ML) and one universal adhesive (UA) used as lubricants during composite layering on the color stability and translucency of RBCs. Methods. The following materials were applied between every 1 mm RBC layer (total restoration height of 4 mm): GC modeling liquid (GCML, GC Corporation, Tokyo, Japan), composite wetting resin (UPWR, Ultradent Products, South Jordan, UT, USA), Bisco modeling resin (BSMR, Bisco Inc., Schaumburg, IL, USA) as an ML and Clearfil Universal Bond Quick (KUBQ, Kuraray Noritake Dental, Tokyo, Japan) as a UA. Lubricant-free specimens were used as the control. Color coordinates (L*, a* and b*) were recorded at baseline and after a simulation of 1 month of coffee consumption. Data were analyzed using ANOVA and a post hoc Tukey test (p &lt; 0.05). Results. All lubricants induced a color change higher than the perceptibility threshold (ΔE00 &gt; 0.81). GCML showed the highest color stability. The use of KUBQ resulted in significantly higher a* values (p = 0.001) at baseline and after staining. KUBQ and UPWR significantly influenced the color stability (ΔE00, p = 0.0001) after staining, overcoming the clinical acceptability threshold (ΔE00 &gt; 1.77). Conclusions. The use of lubricants may affect color stability at baseline and after simulation of staining. Translucency was not affected at baseline nor after staining. Clinical Significance. Clinicians should be aware that some lubricants may affect color stability, even at baseline

    Social cognition in people with schizophrenia: A cluster-analytic approach

    Get PDF
    Background The study aimed to subtype patients with schizophrenia on the basis of social cognition (SC), and to identify cut-offs that best discriminate among subtypes in 809 out-patients recruited in the context of the Italian Network for Research on Psychoses. Method A two-step cluster analysis of The Awareness of Social Inference Test (TASIT), the Facial Emotion Identification Test and Mayer-Salovey-Caruso Emotional Intelligence Test scores was performed. Classification and regression tree analysis was used to identify the cut-offs of variables that best discriminated among clusters. Results We identified three clusters, characterized by unimpaired (42%), impaired (50.4%) and very impaired (7.5%) SC. Three theory-of-mind domains were more important for the cluster definition as compared with emotion perception and emotional intelligence. Patients more able to understand simple sarcasm (14 for TASIT-SS) were very likely to belong to the unimpaired SC cluster. Compared with patients in the impaired SC cluster, those in the very impaired SC cluster performed significantly worse in lie scenes (TASIT-LI &lt;10), but not in simple sarcasm. Moreover, functioning, neurocognition, disorganization and SC had a linear relationship across the three clusters, while positive symptoms were significantly lower in patients with unimpaired SC as compared with patients with impaired and very impaired SC. On the other hand, negative symptoms were highest in patients with impaired levels of SC. Conclusions If replicated, the identification of such subtypes in clinical practice may help in tailoring rehabilitation efforts to the person's strengths to gain more benefit to the person

    Quantitative Volumetric Enamel Loss after Orthodontic Debracketing/Debonding and Clean-Up Procedures: A Systematic Review

    Get PDF
    Objectives: To conduct a systematic review assessing quantitative enamel loss occurring after orthodontic debonding and clean-up procedures. Materials and Methods: A systematic search following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was performed on different databases (Embase, Medline, Scopus, Web of Science) for papers investigating volumetric enamel loss due to bracket and clear aligner attachment debonding and/or clean-up procedures. Studies investigating in vivo and in vitro articles published in the English language until 16 July 2022 were included. The study selection was then performed by two authors who screened the abstracts independently. Results: Of 421 screened abstracts, 41 articles were selected for full-text analysis. Finally, nine studies were included in this review. No in vivo papers were retrieved. In vitro papers investigated volumetric loss caused by the removal of metal brackets (n = 7), ceramic brackets (n = 1), and both (n = 1). The clean-up procedure varied among all investigations. Impressions at baseline and after debonding/clean-up were superimposed, and the volumes were subtracted using different 3D digital analysis software. Among all included studies, the volumetric loss of enamel ranged from 0.02 ± 0.01 mm3 to 0.61 ± 0.51 mm3 per tooth. Conclusions: Debonding and clean-up procedures produce enamel loss. The debonding/clean-up procedure that is able to cause the least enamel volume loss has yet to be identified

    Incompatibility profiles of all-in-one adhesives. II. Contribution of oxygen inhibition

    Get PDF
    published_or_final_versio

    The relationship between peritraumatic distress, mental health symptoms, and functioning impairment in healthcare workers during the COVID-19 emergency

    Get PDF
    Objective. Healthcare workers (HCWs) were considered a population at risk for developing psychiatric symptoms during the COVID-19 pandemic, such as anxiety, depression, and post-traumatic stress disorder (PTSD). Peritraumatic distress is associated with post-traumatic psychopathological symptoms; however, little is known about how it may affect functioning. The study aimed at evaluating the level of peritraumatic distress in a sample of HCWs during the first wave of the COVID-19 pandemic and at examining the relationship between peritraumatic distress, mental health symptoms, and functioning impairment. Methods. A sample of 554 frontline HCWs were consecutively enrolled in major university hospitals and community services in Italy. The PDI, IES-R, PHQ-9, and GAD-7 were used to assess peritraumatic distress, symptoms of PTSD, depression, and anxiety, respectively, and the WSAS to investigate functioning impairment. PDI scores were higher among females, community services, physicians, and nurses. Furthermore, the PDI correlated significantly with the GAD-7, PHQ-9, IES-R, and WSAS. Results. In a mediation analysis, the direct effect of PDI on WSAS and the indirect effects through the PHQ-9 and IES-R were statistically significant (P &lt; .001). Conclusion. Peritraumatic distress reported by HCWs was associated with symptoms of PTSD, depression, and anxiety, but the association with reduced functioning may be only partially mediated through symptoms of depression and PTSD
    corecore