1,147 research outputs found
Prototype high angular resolution LEKIDs for NIKA2
The current resolution of the NIKA2 260 GHz arrays is limited by the
inductor size on the individual pixels. In view of future
updates of the instrument, we have developed a prototype array with smaller
pixels that is experimentally compared to the current pixel design. We find an
in-lab improvement increase of the angular resolution of 8%, promising an
on-sky FWHM resolution of 10.2" using this new pixel design.Comment: 6 pages, 4 figures, submitted to Journal of Low Temperature Detecto
Niobium Silicon alloys for Kinetic Inductance Detectors
We are studying the properties of Niobium Silicon amorphous alloys as a
candidate material for the fabrication of highly sensitive Kinetic Inductance
Detectors (KID), optimized for very low optical loads. As in the case of other
composite materials, the NbSi properties can be changed by varying the relative
amounts of its components. Using a NbSi film with T_c around 1 K we have been
able to obtain the first NbSi resonators, observe an optical response and
acquire a spectrum in the band 50 to 300 GHz. The data taken show that this
material has very high kinetic inductance and normal state surface resistivity.
These properties are ideal for the development of KID. More measurements are
planned to further characterize the NbSi alloy and fully investigate its
potential.Comment: Accepted for publication on Journal of Low Temperature Physics.
Proceedings of the LTD15 conference (Caltech 2013
Lumped element kinetic inductance detectors maturity for space-borne instruments in the range between 80 and 180 GHz
This work intends to give the state-of-the-art of our knowledge of the
performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We
evaluate their optical sensitivity under typical background conditions and
their interaction with ionising particles. Two LEKID arrays, originally
designed for ground-based applications and composed of a few hundred pixels
each, operate at a central frequency of 100, and 150~GHz (
about 0.3). Their sensitivities have been characterised in the laboratory using
a dedicated closed-circle 100~mK dilution cryostat and a sky simulator,
allowing for the reproduction of realistic, space-like observation conditions.
The impact of cosmic rays has been evaluated by exposing the LEKID arrays to
alpha particles (Am) and X sources (Cd) with a readout sampling
frequency similar to the ones used for Planck HFI (about 200~Hz), and also with
a high resolution sampling level (up to 2~MHz) in order to better characterise
and interpret the observed glitches. In parallel, we have developed an
analytical model to rescale the results to what would be observed by such a
LEKID array at the second Lagrangian point.Comment: 7 pages, 2 tables, 13 figure
Uniform non-stoichiometric titanium nitride thin films for improved kinetic inductance detector array
We describe the fabrication of homogeneous sub-stoichiometric titanium
nitride films for microwave kinetic inductance detector (mKID) arrays. Using a
6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the
critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of
a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in
the 100 GHz band, comparable to the best aluminium mKIDs. We measured a noise
equivalent power of NEP = 3.6e-15 W/Hz^(1/2). Finally, we describe possible
routes to further improve the performance of these TiN mKID arrays.Comment: 7 pages, 4 figures, submitted to Journal of low temperature physics,
Proceedings of LTD-1
Bi-layer Kinetic Inductance Detectors for space observations between 80-120 GHz
We have developed Lumped Element Kinetic Inductance Detectors (LEKID)
sensitive in the frequency band from 80 to 120~GHz. In this work, we take
advantage of the so-called proximity effect to reduce the superconducting gap
of Aluminium, otherwise strongly suppressing the LEKID response for frequencies
smaller than 100~GHz. We have designed, produced and optically tested various
fully multiplexed arrays based on multi-layers combinations of Aluminium (Al)
and Titanium (Ti). Their sensitivities have been measured using a dedicated
closed-circle 100 mK dilution cryostat and a sky simulator allowing to
reproduce realistic observation conditions. The spectral response has been
characterised with a Martin-Puplett interferometer up to THz frequencies, and
with a resolution of 3~GHz. We demonstrate that Ti-Al LEKID can reach an
optical sensitivity of about ~ (best pixel), or
~ when averaged over the whole array. The optical
background was set to roughly 0.4~pW per pixel, typical for future space
observatories in this particular band. The performance is close to a
sensitivity of twice the CMB photon noise limit at 100~GHz which drove the
design of the Planck HFI instrument. This figure remains the baseline for the
next generation of millimetre-wave space satellites.Comment: 7 pages, 9 figures, submitted to A&
NIKEL_AMC: Readout electronics for the NIKA2 experiment
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at
the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to
mm-wave astronomy using microwave kinetic inductance detectors (KID) as
sensors. The three arrays installed in the camera, two at 1.25 mm and one at
2.05 mm, feature a total of 3300 KIDs. To instrument these large array of
detectors, a specifically designed electronics, composed of 20 readout boards
and hosted in three microTCA crates, has been developed. The implemented
solution and the achieved performances are presented in this paper. We find
that multiplexing factors of up to 400 detectors per board can be achieved with
homogeneous performance across boards in real observing conditions, and a
factor of more than 3 decrease in volume with respect to previous generations.Comment: 21 pages; 16 figure
Single passage in mouse organs enhances the survival and spread of Salmonella enterica.
Intravenous inoculation of Salmonella enterica serovar Typhimurium into mice is a prime experimental model of invasive salmonellosis. The use of wild-type isogenic tagged strains (WITS) in this system has revealed that bacteria undergo independent bottlenecks in the liver and spleen before establishing a systemic infection. We recently showed that those bacteria that survived the bottleneck exhibited enhanced growth when transferred to naive mice. In this study, we set out to disentangle the components of this in vivo adaptation by inoculating mice with WITS grown either in vitro or in vivo. We developed an original method to estimate the replication and killing rates of bacteria from experimental data, which involved solving the probability-generating function of a non-homogeneous birth-death-immigration process. This revealed a low initial mortality in bacteria obtained from a donor animal. Next, an analysis of WITS distributions in the livers and spleens of recipient animals indicated that in vivo-passaged bacteria started spreading between organs earlier than in vitro-grown bacteria. These results further our understanding of the influence of passage in a host on the fitness and virulence of Salmonella enterica and represent an advance in the power of investigation on the patterns and mechanisms of host-pathogen interactions.This work was funded by a Medical Research Council (MRC) grant (G0801161) awarded to AJG, PM and DJM. RD was supported by BBSRC grant BB/I002189/1 awarded to PM. OR is supported by a University Research Fellowship from the Royal Society.This is the final version of the article. It was first available from Royal Society Publishing via http://dx.doi.org/10.1098/rsif.2015.070
Lumped Element Kinetic Inductance Detectors for space applications
Kinetic Inductance Detectors (KID) are now routinely used in ground-based
telescopes. Large arrays, deployed in formats up to kilopixels, exhibit
state-of-the-art performance at millimeter (e.g. 120-300 GHz, NIKA and NIKA2 on
the IRAM 30-meters) and sub-millimeter (e.g. 350-850 GHz AMKID on APEX)
wavelengths. In view of future utilizations above the atmosphere, we have
studied in detail the interaction of ionizing particles with LEKID (Lumped
Element KID) arrays. We have constructed a dedicated cryogenic setup that
allows to reproduce the typical observing conditions of a space-borne
observatory. We will report the details and conclusions from a number of
measurements. We give a brief description of our short term project, consisting
in flying LEKID on a stratospheric balloon named B-SIDE.Comment: To appear in the SPIE 2016 Proceeding
The NIKA instrument: results and perspectives towards a permanent KID based camera for the Pico Veleta observatory
The New IRAM KIDs Array (NIKA) is a pathfinder instrument devoted to
millimetric astronomy. In 2009 it was the first multiplexed KID camera on the
sky; currently it is installed at the focal plane of the IRAM 30-meters
telescope at Pico Veleta (Spain). We present preliminary data from the last
observational run and the ongoing developments devoted to the next NIKA-2
kilopixels camera, to be commissioned in 2015. We also report on the latest
laboratory measurements, and recent improvements in detector cosmetics and
read-out electronics. Furthermore, we describe a new acquisition strategy
allowing us to improve the photometric accuracy, and the related automatic
tuning procedure.Comment: 24th International Symposium on Space Terahertz Technology, ISSTT
2013, April 8 to 10, 2013, Groningen, the Netherland
Latest NIKA results and the NIKA-2 project
NIKA (New IRAM KID Arrays) is a dual-band imaging instrument installed at the
IRAM (Institut de RadioAstronomie Millimetrique) 30-meter telescope at Pico
Veleta (Spain). Two distinct Kinetic Inductance Detectors (KID) focal planes
allow the camera to simultaneously image a field-of-view of about 2 arc-min in
the bands 125 to 175 GHz (150 GHz) and 200 to 280 GHz (240 GHz). The
sensitivity and stability achieved during the last commissioning Run in June
2013 allows opening the instrument to general observers. We report here the
latest results, in particular in terms of sensitivity, now comparable to the
state-of-the-art Transition Edge Sensors (TES) bolometers, relative and
absolute photometry. We describe briefly the next generation NIKA-2 instrument,
selected by IRAM to occupy, from 2015, the continuum imager/polarimeter slot at
the 30-m telescope.Comment: Proceedings of Low Temperature Detectors 15 (LTD-15), Pasadena, June
201
- …