904 research outputs found
Wage Discrimination Between Jews and Non-Jews in Israel
Rapport de recherche présenté à la Faculté des arts et des sciences en vue de l'obtention du grade de Maîtrise en sciences économiques
Rheological study of sludge of membranes bioreactors for water treatment: protocol, limitations and link with the filtration
The submerged membranes bio-reactors (sMBR) are more and more visible in the field of waste water treatment. The membrane fouling, that causes a drastic fall of the performances, can be limited by the application of a swarm of bubbles close to the membrane surfaces. This aeration as a major factor of the energetic expense of these processes, lets numerous studies to focus on the understanding of the mechanisms linking the bubbles swarm with fouling.. In this background, the rheological tools appeared to be useful to understand the behaviour of sludge under shear stress. In order to be sure to get significant results, we used three types of rheological measurements: i) the influence of shear rate on shear stress; ii) the influence of upward then downward stages of shear stress on viscosity; iii) the influence of the alternation of two stages of shear stress with implementation times identical to those of sMBR aeration. Besides a viscoplastic behaviour previously observed, a phenomenon of hysteresis appeared. The transparent upper plan used on the rheometer exhibited formations of aggregative structures “in roll”. Sludges of a sMBR using different sequencing of aeration are compared: the developed protocols enabled to differentiate those sludges, with characteristic results depending on mechanical applications. The aim of this work is, eventually, to propose some correlations between usual characteristics of the process and aeration operating parameters, in order to propose an aeration policy improving energetic performances
Simulation d’une filtration liquide en canal poreux fermé à une extrémité avec prise en compte de la formation du dépôt
La formation d’un dépôt de filtration ainsi
que les performances de filtration associées ont été étudiées par CFD en utilisant un
maillage mobile. Des lois expérimentales décrivant la porosité et la perméabilité du
dépôt ont été intégrées au modèle. Ces lois ont été obtenues à partir de la mesure
d’épaisseur de dépôt in situ par nappe laser. L’effet d’une perméabilité membranaire non
uniforme sur la distribution spatiale du dépôt a ensuite été étudié
Étude comparative de l’électrocoagulation et de la coagulation floculation vis-à-vis de la déstabilisation d’une émulsion d’huile de coupe
Ce travail a porté sur la déstabilisation d’une émulsion d’huile de coupe algérienne (Tasfalout 22/B) par électrocoagulation (EC) en batch en utilisant des électrodes de fer. L’efficacité du procédé est évaluée par la mesure de la turbidité. Une meilleure efficacité de déstabilisation est obtenue par une augmentation de la densité de courant de 50 à 350 A•m‑2 pour un temps d’électrolyse de 15 min et des concentrations en huile de coupe de 1 % (p/p), 2 % (p/p) et 4 %(p/p). Un rendement d’élimination en turbidité de 99 % a été obtenu pour une émulsion à 4 % (p/p), une densité de courant de 150 A•m‑2 et un temps d’électrolyse de 120 min.Le suivi de la cinétique de dissolution de l’électrode de fer sur une période de 120 minutes a montré qu’une même efficacité du procédé peut être obtenue par une diminution du temps d’électrolyse et une augmentation de la densité de courant.Une étude comparative des performances de l’électrocoagulation et de la coagulation-floculation au chlorure ferrique hydraté (FeCl3•6H2O), vis-à-vis de la déstabilisation d’une émulsion d’huile de coupe, a été réalisée. Elle a mis en évidence l’avantage de la coagulation-floculation pour l’émulsion à 1 % (p/p), pour les différentes densités de courant testées en électrocoagulation. Par contre, les rendements d’élimination pour les deux procédés sont sensiblement similaires pour les émulsions plus concentrées (2 % (p/p) et 4 % (p/p)), pour une densité de courant de 150 A•m‑2. Le pH des émulsions obtenu par les deux procédés après le traitement est différent. Le milieu reste alcalin dans l’électrocoagulation et il devient acide dans la coagulation floculation.This work focuses on the breakdown of an Algerian cutting oil emulsion (Tasfalout 22/B) by batch electrocoagulation (EC) using iron electrodes. The efficiency of the process was estimated from turbidity measurements. An improved efficiency of destabilization was obtained by increasing the current density from 50 to 350 A•m‑2, over an electrolysis time of 15 min and using cutting oil concentrations of 1% (w/w), 2% (w/w) and 4% (w/w). Monitoring of the kinetics of the electrode dissolution over a period of 120 min showed that a similar process efficiency was obtained by decreasing the electrolysis time and by increasing the current density. A 99% removal of turbidity was obtained for an emulsion of 4% (w/w) with a current density of 150 A•m‑2 and an electrolysis time of 120 min.A comparison of the performances of electrocoagulation and of coagulation-flocculation with hydrated ferric chloride (FeCl3•6H2O) processes was carried out, with respect to the destabilization of cutting oil emulsion. This comparison highlighted the advantage of the coagulation-flocculation process for the of 1% (w/w) emulsion at different electrocoagulation current densities. However, for a current density of 150 A•m‑2, the removal efficiency of both processes was similar for the emulsion with higher cutting oil concentrations (2% (w/w) and 4% (w/w)). The pH of the emulsion obtained by the two processes following treatment varied. The medium remained alkaline during the electrocoagulation process and became acidic during the coagulation-flocculation process
Global dissipativity and quasi-Mittag-Leffler synchronization of fractional-order complex-valued neural networks with time delays and discontinuous activations
This paper explores fractional-order complex-valued neural networks (FOCVNNs) with time delays and discontinuous activation functions. A novel fractional-order inequality is utilized to study this system as a whole without dividing it into different components in the complex plane. Firstly, the existence of global Filippov solutions in the complex domain is proven by using the theories of vector norms and fractional calculus. Next, some sufficient conditions are derived to ensure the global dissipativity and quasi-Mittag-Leffler synchronization of FOCVNNs through the use of nonsmooth analysis and differential inclusion theory. The error bounds of quasi-Mittag-Leffler synchronization are also estimated without relying on the initial values. Finally, some numerical simulations are conducted to demonstrate the effectiveness of the presented findings
RFID : L'attaque sangsue est-elle réalisable à plus de 30 cm d'un transpondeur HF?
RÉSUMÉ
La technologie RFID (Radio Frequency IDentification) permet l’identification sans fil de transpondeurs qui souvent ne contiennent pas de source d’alimentation propre. La technologie NFC (Near Field Communication) vient prolonger cette première solution en ne se limitant plus seulement à l’identification, mais plus généralement à la communication sans fil. Ces deux technologies sont de plus en plus présentes dans notre quotidien. En effet, la RFID est aujourd’hui très employée dans des domaines aussi variés que le contrôle d’accès, les transports en commun, la santé, les entreprises et les universités. Elle commence maintenant à apparaître dans les cartes de paiement et les passeports. Par ailleurs, les téléphones intelligents sont de plus en plus nombreux à intégrer la technologie NFC.
Dans ce contexte, il est essentiel de s’assurer que les informations échangées lors d’une communication soient correctement protégées pour prévenir d’éventuelles fraudes, usurpa- tions d’identité ou vols d’informations confidentielles. Or, un des arguments souvent avancé, pour justifier la sécurité de la RFID en bande HF et de NFC dans les applications grand public, est leur faible distance de lecture de quelques centimètres.
Dans un premier temps, nous avons ainsi cherché à établir théoriquement la distance maxi- male de lecture de différents transpondeurs HF en proposant un nouveau modèle d’attaque : nous supposons que le lecteur de l’attaquant peut fonctionner à une fréquence différente de
13.56 MHz, contrairement à un lecteur ordinaire. En effet, la fréquence de résonance de cer-
tains transpondeurs HF est supérieure à cette porteuse. Nous avons trouvé que la distance de lecture varie significativement d’un transpondeur à l’autre et qu’accorder le lecteur sur la fréquence de résonance du transpondeur permet parfois d’augmenter considérablement la portée de l’attaque.
Dans un second temps, nous avons cherché à adresser une des difficultés techniques posées par la fabrication d’un lecteur ayant une portée importante : le filtrage de la porteuse dans son circuit de réception. Nous avons ainsi proposé un filtre passif d’ordre 5 capable de filtrer 65 dB de porteuse. Cette atténuation n’est cependant pas suffisante pour atteindre des distances de lecture intéressantes sans ajouter un second étage de filtrage. Nous avons également proposé une expérience pour vérifier le bon fonctionnnement du filtre.----------ABSTRACT
RFID (Radio Frequency IDentification) allows remote identification of wireless devices that often do not contain a power supply. NFC (Near Field Communication) extends the protocol stack of HF RFID to wireless communication. In recent years, those two technologies have rapidly spread. RFID based access control is used by many transit systems, universities and entreprises. Passports and credit cards now feature NFC chips, along with modern smartphones.
In this context, enforcing the security of communication protocols used in those applica- tions is of utmost importance if frauds, confidential information theft and identity theft are to be avoided. Yet, a recurring argument to prove the intrinsic security of HF RFID and NFC is that their range is limited to a few centimeters at best.
To challenge that argument, we first established a theorical model to estimate the maximal
read distance of HF RFID tags. We considered a new threat model where the attacker can tune his reader to a different frequency than 13.56 MHz. Indeed, the resonant frequency of HF RFID tags is often higher than the carrier frequency of readers. We found out that this hack could significantly increase the read range of certain tags. We also observed that the read out distance strongly depends on characteristics that vary from one tag to another.
Secondly, we addressed one of the difficulties posed by the implementation of a reader with an extended read range: the cancellation of the carrier in the receiver circuit. Thus, we designed a 5 order passive filter attenuating 65 dB of carrier. We also proposed an experience to test how well it could fit in a real RFID system, but unfortunately its response is not sufficient to achieve interesting read out distances
What Do Family Caregivers of Alzheimer's Disease Patients Desire in Smart Home Technologies?
Objectives - The authors' aim was to investigate the representations, wishes,
and fears of family caregivers (FCs) regarding 14 innovative technologies (IT)
for care aiding and burden alleviation, given the severe physical and
psychological stress induced by dementia care, and the very slow uptake of
these technologies in our society. Methods - A cluster sample survey based on a
self-administered questionnaire was carried out on data collected from 270
families of patients with Alzheimer's disease or related disorders, located in
the greater Paris area. Multiple Correspondence Analysis was used in addition
to usual statistical tests to identify homogenous FCs clusters concerning the
appreciation or rejection of the considered technologies. Results - Two
opposite clusters were clearly defined: FCs in favor of a substantial use of
technology, and those rather or totally hostile. Furthermore the distributions
of almost all the answers of appreciations were U shaped. Significant relations
were demonstrated between IT appreciation and FC's family or gender statuses
(e.g., female FCs appreciated more than male FCs a tracking device for quick
recovering of wandering patients: p=0.0025, N=195). Conclusions - The study
provides further evidence of the contrasted perception of technology in
dementia care at home, and suggests the development of public debates based on
rigorous assessment of practices and a strict ethical aim to protect against
misuse
- …
