2,269 research outputs found
Dihydroartemisinin-piperaquine versus artesunate-amodiaquine for treatment of malaria infection in pregnancy in Ghana: an open-label, randomized, non-inferiority trial.
To determine whether dihydroartemisinin-piperaquine (DHA-PPQ) is non-inferior to artesunate-amodiaquine (ASAQ) for treating uncomplicated malaria infection in pregnancy.
417 second/ third trimester pregnant women with confirmed asymptomatic Plasmodium falciparum parasitaemia were randomized to receive DHA-PPQ or ASAQ over 3 days. Women were followed up on days 1, 2, 3, 7, 14, 28 and 42 after treatment start and at delivery for parasitological, haematological, birth outcomes and at 6-weeks post-partum to ascertain the health status of the babies. Parasitological efficacy (PE) by days 28 and 42 were co-primary outcomes. Analysis was per-protocol (PP) and modified intention-to-treat (ITT). Non-inferiority was declared if the two-sided 95% confidence interval for PE at the endpoints excluded 5% lower efficacy for DHA-PPQ. Secondary outcomes were assessed for superiority.
In PP analysis, PE was 91.6% for DHA-PPQ and 89.3% for ASAQ by day 28 and 89.0% and 86.5% respectively by day 42. DHA-PPQ was non-inferior to ASAQ with respect to uncorrected PE {adjusted difference by day 28 (DHA-PPQ-ASAQ); 3.5% (95%CI: -1.5, 8.5) and day 42: 3.9% (95%CI: -2.7, 10.4)}. ITT analysis gave similar results. PCR to distinguish recrudescence and reinfection was unsuccessful. DHA-PPQ recipients had fewer adverse events of vomiting, dizziness and general weakness compared to ASAQ. Both drugs were well-tolerated and there was no excess of adverse birth outcomes.
DHA-PPQ was non-inferior to ASAQ for treatment of malaria infection during pregnancy. No safety concerns were identified. Our findings contribute to growing evidence that DHA-PPQ is useful for control of malaria in pregnancy. This article is protected by copyright. All rights reserved
Modeling the effects of concentration of solid nanoparticles in liquid feedstock injection on high-velocity suspension flame spray process
This paper presents the effects of the concentration of solid nanoparticles in the liquid feedstock injection on the
high-velocity suspension flame spray (HVSFS) process. Four different concentrations of solid nanoparticles in suspension
droplets with various droplet diameters are used to study gas dynamics, vaporization rate, and secondary breakup. Two types of
injections, viz. surface and group, are used. The group-type injection increases the efficiency of droplet disintegration and the
evaporation process and reduces the gas cooling. The initiation of the fragmentation process is difficult for small droplets carrying
a high concentration of nanoparticles. Also, smaller droplets undergo rapid vaporization, leaving clogs of nanoparticles in the
middle of the barrel. For larger droplets, severe fragmentation occurs inside the combustion chamber. For a higher concentration
of nanoparticles, droplets exit the gun without complete evaporation. The results suggest that, in coating applications involving a
higher concentration of nanoparticles, smaller droplet sizes are preferred
Treatment of Advanced Emphysema with Emphysematous Lung Sealant (AeriSeal (R))
Background: This report summarizes initial tests of an emphysematous lung synthetic polymer sealant (ELS) designed to reduce lung volume in patients with advanced emphysema. Objectives: The primary study objective was to define a therapeutic strategy to optimize treatment safety and effectiveness. Methods: ELS therapy was administered bronchoscopically to 25 patients with heterogeneous emphysema in an open-label, noncontrolled study at 6 centers in Germany. Treatment was performed initially at 2-4 subsegments. After 12 weeks, patients were eligible for repeat therapy to a total of 6 sites. Safety and efficacy were assessed after 6 months. Responses were evaluated in terms of changes from baseline in lung physiology, functional capacity, and health-related quality of life. Follow-up is available for 21 of 25 patients. Results: Treatment was well tolerated. There were no treatment-related deaths (i.e. within 90 days of treatment), and an acceptable short-and long-term safety profile. Physiological and clinical benefits were observed at 24 weeks. Efficacy responses were better among Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage III patients {[}n = 14; change in residual volume/total lung capacity (Delta RV/TLC) = -7.4 +/- 10.3%; Delta forced expiratory volume in 1 s (Delta FEV(1)) = +15.9 +/- 22.6%; change in forced vital capacity (Delta FVC) = +24.1 +/- 22.7%; change in carbon monoxide lung diffusion capacity (Delta DLCO) = +19.3 +/- 34.8%; change in 6-min walk test (Delta 6MWD) = +28.7 +/- 59.6 m; change in Medical Research Council Dyspnea (Delta MRCD) score = -1.0 +/- 1.04 units; change in St. George's Respiratory Questionnaire (Delta SGRQ) score = -9.9 +/- 15.3 units] than for GOLD stage IV patients (n = 7; Delta RV/TLC = -0.5 +/- 6.4%; Delta FEV 1 = +2.3 +/- 12.3%; Delta FVC = +2.6 +/- 21.1%; Delta DLCO = -2.8 +/- 17.2%; Delta 6MWD = +28.3 +/- 58.4 m; Delta MRCD = 0.3 +/- 0.81 units; Delta SGRQ = -6.7 +/- 7.0 units). Conclusions: ELS therapy shows promise for treating patients with advanced heterogeneous emphysema. Additional studies to assess responses in a larger cohort with a longer follow-up are warranted. Copyright (C) 2011 S. Karger AG, Base
Rejection of the hypothesis that Markarian 501 TeV photons are pure Bose-Einstein condensates
The energy spectrum of the Blazar type galaxy Markarian 501 (Mrk 501) as
measured by the High-Energy-Gamma-Ray Astronomy (HEGRA) air Cerenkov telescopes
extends beyond 16 TeV and constitutes the most energetic photons observed from
an extragalactic object. A fraction of the emitted spectrum is possibly
absorbed in interactions with low energy photons of the diffuse extragalactic
infrared radiation, which in turn offers the unique possibility to measure the
diffuse infrared radiation density by TeV spectroscopy. The upper limit on the
density of the extragalactic infrared radiation derived from the TeV
observations imposes constraints on models of galaxy formation and stellar
evolution. One of the recently published ideas to overcome severe absorption of
TeV photons is based upon the assumption that sources like Mrk 501 could
produce Bose-Einstein condensates of coherent photons. The condensates would
have a higher survival probability during the transport in the diffuse
radiation field and could mimic TeV air shower events. The powerful
stereoscopic technique of the HEGRA air Cerenkov telescopes allows to test this
hypothesis by reconstructing the penetration depths of TeV air shower events:
Air showers initiated by Bose-Einstein condensates are expected to reach the
maximum of the shower development in the atmosphere earlier than single photon
events. By comparing the energy-dependent penetration depths of TeV photons
from Mrk 501 with those from the TeV standard-candle Crab Nebula and simulated
air shower events, we can reject the hypothesis that TeV photons from Mrk 501
are pure Bose-Einstein condensates.Comment: 9 pages, 2 figures, published by ApJ Letters, revised version
(simulation results added
Surface Structure of Liquid Metals and the Effect of Capillary Waves: X-ray Studies on Liquid Indium
We report x-ray reflectivity (XR) and small angle off-specular diffuse
scattering (DS) measurements from the surface of liquid Indium close to its
melting point of C. From the XR measurements we extract the surface
structure factor convolved with fluctuations in the height of the liquid
surface. We present a model to describe DS that takes into account the surface
structure factor, thermally excited capillary waves and the experimental
resolution. The experimentally determined DS follows this model with no
adjustable parameters, allowing the surface structure factor to be deconvolved
from the thermally excited height fluctuations. The resulting local electron
density profile displays exponentially decaying surface induced layering
similar to that previously reported for Ga and Hg. We compare the details of
the local electron density profiles of liquid In, which is a nearly free
electron metal, and liquid Ga, which is considerably more covalent and shows
directional bonding in the melt. The oscillatory density profiles have
comparable amplitudes in both metals, but surface layering decays over a length
scale of \AA for In and \AA for Ga. Upon controlled
exposure to oxygen, no oxide monolayer is formed on the liquid In surface,
unlike the passivating film formed on liquid Gallium.Comment: 9 pages, 5 figures; submitted to Phys. Rev.
Determinants of initial inhaled corticosteroid use in patients with GOLD A/B COPD:a retrospective study of UK general practice
Initial use of inhaled corticosteroid therapy is common in patients with Global Initiative for Chronic Obstructive Lung Disease (GOLD) A or B chronic obstructive pulmonary disease, contrary to GOLD guidelines. We investigated UK prescribing of inhaled corticosteroid therapy in these patients, to identify predictors of inhaled corticosteroid use in newly diagnosed chronic obstructive pulmonary disease patients. A cohort of newly diagnosed GOLD A/B chronic obstructive pulmonary disease patients was identified from the UK Clinical Practice Research Datalink (June 2005–June 2015). Patients were classified by prescribed treatment, with those receiving inhaled corticosteroid-containing therapy compared with those receiving long-acting bronchodilators without inhaled corticosteroid. In all, 29,815 patients with spirometry-confirmed chronic obstructive pulmonary disease were identified. Of those prescribed maintenance therapy within 3 months of diagnosis, 63% were prescribed inhaled corticosteroid-containing therapy vs. 37% prescribed non-inhaled corticosteroid therapy. FEV1% predicted, concurrent asthma diagnosis, region, and moderate exacerbation were the strongest predictors of inhaled corticosteroid use in the overall cohort. When concurrent asthma patients were excluded, all other co-variates remained significant predictors. Other significant predictors included general practitioner practice, younger age, and co-prescription with short-acting bronchodilators. Trends over time showed that initial inhaled corticosteroid prescriptions reduced throughout the study, but still accounted for 47% of initial prescriptions in 2015. These results suggest that inhaled corticosteroid prescribing in GOLD A/B patients is common, with significant regional variation that is independent of FEV1% predicted
The TeV Energy Spectrum of Mkn 501 Measured with the Stereoscopic Telescope System of HEGRA during 1998 and 1999
During 1997, the BL Lac object Mkn 501 went into an extraordinary state of
high X-ray and TeV gamma-ray activity, lasting more than 6 months. In this
paper we report on the TeV emission characteristics of the source in the
subsequent years of 1998 and 1999 as measured with the Stereoscopic Cherenkov
Telescope System of HEGRA (La Palma, Canary Islands). Our observations reveal a
1998-1999 mean emission level at 1 TeV of 1/3 of the flux of the Crab Nebula, a
factor of 10 lower than during the year of 1997. A dataset of 122 observations
hours with the HEGRA telescope system makes it possible to assess for the first
time the Mkn 501 TeV energy spectrum for a mean flux level substantially below
that of the Crab Nebula with reasonable statistical accuracy. Excluding the
data of a strong flare, we find evidence that the 1998--1999 low-flux spectrum
is substantially softer (by 0.44+-0.1(stat) in spectral index) than the 1997
time averaged spectrum. The 500 GeV to 10 TeV energy spectrum can well be
described by a power law model with exponential cutoff: dN/dE ~ E^(-alpha)
exp(-E/E0) with alpha=2.31+-0.22(stat), and E0=5.1 (-2.3+7.8)(stat) TeV. Within
statistical accuracy, also a pure power law model gives an acceptable fit to
the data: dN/dE ~ E^(-Gamma) with Gamma=2.76+-0.08(stat). After presenting the
1998-1999 TeV characteristics of the source we discuss the implications of the
results.Comment: Accepted for publication in The Astrophysical Journal, Part 1, on
August 4th, 200
Comparing the Effect of Concept Mapping and Conventional Methods on Nursing Students' Practical Skill Score
Background: Development of practical skills in the field of nursing education has remained a serious and considerable challenge in nursing education. Moreover, newly graduated nurses may have weak practical skills, which can be a threat to patients’ safety.
Objectives: The present study was conducted to compare the effect of concept mapping and conventional methods on nursing students’ practical skills.
Patients and Methods: This quasi-experimental study was conducted on 70 nursing students randomly assigned into two groups of 35 people. The intervention group was taught through concept mapping method, while the control group was taught using conventional method. A two-part instrument was used including a demographic information form and a checklist for direct observation of procedural skills. Descriptive statistics, chi-square, independent samples t-tests and paired t-test were used to analyze data.
Results: Before education, no significant differences were observed between the two groups in the three skills of cleaning (P = 0.251), injection (P = 0.185) and sterilizing (P = 0.568). The students mean scores were significantly increased after the education and the difference between pre and post intervention of students mean scores were significant in the both groups (P < 0.001). However, after education, in all three skills the mean scores of the intervention group were significantly higher than the control group (P < 0.001).
Conclusions: Concept mapping was superior to conventional skill teaching methods. It is suggested to use concept mapping in teaching practical courses such as fundamentals of nursing
- …
