58 research outputs found
Accurate water maser positions from HOPS
We report on high spatial resolution water maser observations, using the Australia Telescope Compact Array, towards water maser sites previously identified in the H2O southern Galactic Plane Survey (HOPS). Of the 540 masers identified in the single-dish observations of Walsh et al. (2011), we detect emission in all but 31 fields. We report on 2790 spectral features (maser spots), with brightnesses ranging from 0.06 Jy to 576 Jy and with velocities ranging from −238.5 to +300.5 kms−1. These spectral features are grouped into 631 maser sites. We have compared the positions of these sites to the literature to associate the sites with astrophysical objects. We identify 433 (69 per cent) with star formation, 121 (19 per cent) with evolved stars and 77 (12 per cent) as unknown. We find that maser sites associated with evolved stars tend to have more maser spots and have smaller angular sizes than those associated with star formation. We present evidence that maser sites associated with evolved stars show an increased likelihood of having a velocity range between 15 and 35 kms−1 compared to other maser sites. Of the 31 non-detections, we conclude they were not detected due to intrinsic variability and confirm previous results showing that such variable masers
tend to be weaker and have simpler spectra with fewer peaks
MALT-45: a 7 mm survey of the southern Galaxy - I. Techniques and spectral line data
We present the first results from the MALT-45 (Millimetre Astronomer's Legacy Team-45 GHz) Galactic Plane survey. We have observed 5 square degrees (l = 330°–335°, b = ±0 ∘ . 5) for spectral lines in the 7 mm band (42–44 and 48–49 GHz), including CS (1–0), class I CH3OH masers in the 7(0,7)–6(1,6) A+ transition and SiO (1–0) v = 0, 1, 2, 3. MALT-45 is the first unbiased, large-scale, sensitive spectral line survey in this frequency range. In this paper, we present data from the survey as well as a few intriguing results; rigorous analyses of these science cases are reserved for future publications. Across the survey region, we detected 77 class I CH3OH masers, of which 58 are new detections, along with many sites of thermal and maser SiO emission and thermal CS. We found that 35 class I CH3OH masers were associated with the published locations of class II CH3OH, H2O and OH masers but 42 have no known masers within 60 arcsec. We compared the MALT-45 CS with NH3 (1,1) to reveal regions of CS depletion and high opacity, as well as evolved star-forming regions with a high ratio of CS to NH3. All SiO masers are new detections, and appear to be associated with evolved stars from the Spitzer Galactic Legacy Infrared Mid-Plane Survey Extraordinaire (GLIMPSE). Generally, within SiO regions of multiple vibrational modes, the intensity decreases as v = 1, 2, 3, but there are a few exceptions where v = 2 is stronger than v = 1
Hypovitaminosis D is associated with negative outcome in dogs with protein losing enteropathy: a retrospective study of 43 cases
Abstract Background Hypovitaminosis D has previously been shown to be prevalent amongst dogs with protein losing enteropathy (PLE). The hypothesis of this study was that Low 25-hydroxyvitamin D (25(OH) D) serum concentrations could be a risk factor for negative outcome in dogs with PLE. Forty-three dogs diagnosed with PLE (2005–2014) and which serum Vitamin D serum concentrations were collected and archived at −80 Degrees C were analyzed. Post-diagnostic communication with referring veterinarians was made to determine outcome of PLE dogss: Dogs which died due to PLE within 4 months after diagnosis (negative outcome group, n = 22) and dogs alive or which died due to another disease at the end point of the study (1 year after diagnosis, good outcome group, n = 21). Serum samples taken at the time of diagnosis were analysed for ionized calcium (iCa) concentrations and serum 25(OH) D concentration. Results Clinical (CCECAI) scores, age at PLE diagnosis, and iCa concentrations were not significantly different between dog groups. A significantly greater (p < 0.001) number of PLE dogs treated with hydrolyzed or elimination diet alone showed good outcome as compared to the PLE negative outcome group. Median serum 25(OH) D concentration was significantly (p = 0.017) lower in dogs with negative outcome versus PLE dogs with good outcome. Using logistic regression analysis, 25(OH) D serum concentration was shown to be a statistically significant factor for outcome determination. Cox regression analysis yielded a hazard ratio of 0.974 (95% CI 0.949, 0.999) per each one nmol/l increase in serum 25(OH) D concentration. Conclusions Low serum 25(OH) D concentration in PLE dogs was significantly associated with poor outcome. Further studies are required to investigate the clinical efficacy of Vitamin D (cholecalciferol) as a potential therapeutic agent for dogs with PLE
MALT90: The Millimetre Astronomy Legacy Team 90 GHz Survey
The Millimetre Astronomy Legacy Team 90 GHz (MALT90) survey aims to characterise the physical and
chemical evolution of high-mass star-forming clumps. Exploiting the unique broad frequency range and on-
the-fly mapping capabilities of the Australia Telescope National Facility Mopra 22 m single-dish telescope∗ , MALT90 has obtained 3′ × 3′ maps toward _2000 dense molecular clumps identified in the ATLASGAL 870 μm Galactic plane survey. The clumps were selected to host the early stages of high-mass star formation and to span the complete range in their evolutionary states (from prestellar, to protostellar, and on to HII regions and photodissociation regions). Because MALT90 mapped 16 lines simultaneously with excellent spatial (38) and spectral (0.11 km s−1) resolution, the data reveal a wealth of information about the clump’s morphologies, chemistry, and kinematics. In this paper we outline the survey strategy, observing mode, data reduction procedure, and highlight some early science results. All MALT90 raw and processed data products are available to the community. With its unprecedented large sample of clumps, MALT90 is the largest survey of its type ever conducted and an excellent resource for identifying interesting candidates for high resolution studies with ALMA
Vitamin d status predicts 30 day mortality in hospitalised cats
Vitamin D insufficiency, defined as low serum concentrations of the major circulating form of vitamin D, 25 hydroxyvitamin D (25(OH)D), has been associated with the development of numerous infectious, inflammatory, and neoplastic disorders in humans. In addition, vitamin D insufficiency has been found to be predictive of mortality for many disorders. However, interpretation of human studies is difficult since vitamin D status is influenced by many factors, including diet, season, latitude, and exposure to UV radiation. In contrast, domesticated cats do not produce vitamin D cutaneously, and most cats are fed a commercial diet containing a relatively standard amount of vitamin D. Consequently, domesticated cats are an attractive model system in which to examine the relationship between serum 25(OH)D and health outcomes. The hypothesis of this study was that vitamin D status would predict short term, all-cause mortality in domesticated cats. Serum concentrations of 25(OH)D, together with a wide range of other clinical, hematological, and biochemical parameters, were measured in 99 consecutively hospitalised cats. Cats which died within 30 days of initial assessment had significantly lower serum 25(OH)D concentrations than cats which survived. In a linear regression model including 12 clinical variables, serum 25(OH)D concentration in the lower tertile was significantly predictive of mortality. The odds ratio of mortality within 30 days was 8.27 (95% confidence interval 2.54-31.52) for cats with a serum 25(OH)D concentration in the lower tertile. In conclusion, this study demonstrates that low serum 25(OH)D concentration status is an independent predictor of short term mortality in cats
Low vitamin D status is associated with systemic and gastrointestinal inflammation in dogs with a chronic enteropathy
Vitamin D is traditionally known for its role in calcium homeostasis and bone metabolism.
However, it has been demonstrated that numerous types of cells express the vitamin D
receptor and it is now clear that the physiological roles of vitamin D extend beyond the
maintenance of skeletal health. Vitamin D insufficiency, which is typically assessed by
measuring the major circulating form of vitamin D, 25 hydroxyvitamin D (25(OH)D), has
been associated with a number of disorders in people including hypertension, diabetes,
cardiovascular diseases, cancer, autoimmune conditions and infectious diseases. Meta-analyses
have demonstrated that serum 25(OH)D concentrations are an important predictor
of survival in people with a wide variety of illnesses and have been linked to all-cause
mortality in the general human population.
The role of vitamin D in non-skeletal disorders in cats and dogs is poorly understood. This is
surprising since cats and dogs could act as excellent models for probing the biology of
vitamin D. Vitamin D status in people is largely dependent on cutaneous production of
vitamin D. This is influenced by many factors such as season, latitude and exposure to
ultraviolet (UV) radiation. The interpretation of human studies investigating the effects
vitamin D status on disease outcomes are therefore influenced by a number of confounding
variables. Unlike humans, domesticated cats and dogs do not produce vitamin D cutaneously
and obtain vitamin D only from their diet. The physiological functions and regulation of
vitamin D are otherwise similar to humans. Most pets are fed commercial diets containing a
relatively standard amount of vitamin D. Consequently, companion animals are attractive
model systems in which to examine the relationship vitamin D status and health outcomes.
Furthermore, spontaneously occurring model systems which did not require disease to be
induced in healthy animals would allow the numbers of animals used in scientist research to
be reduced.
This thesis aimed to define vitamin D homeostasis in companion animals in three disease
settings; in cats with feline immunodeficiency virus (FIV) infection, dogs with chronic
enteropathies (CE) and in hospitalised ill cats. Additional aims were to assess the prognostic
significance of serum 25(OH)D concentrations in companion animals and the relationship
between serum 25(OH)D concentrations and markers of inflammation. The hypothesis of
this thesis was that vitamin status D would negatively correlate with presence of disease,
markers of inflammation and disease outcomes. As similar findings have been demonstrated
in human medicine, the hypothesis was that cats and dogs would be suitable models to
investigate the role of vitamin D in human disease.
This thesis demonstrates that in dogs with a CE serum 25(OH)D concentrations are
negatively correlated with inflammation and are predictive of clinical outcomes. Vitamin D
status was also lower in cats with FIV and importantly vitamin D status was predictive of
short term mortality in hospitalised ill cats. This research will be of interest to veterinary
surgeons and opens the possibility for clinical trials which examine if low vitamin D status is
causally associated with ill health and whether vitamin D supplementation results in superior
treatment outcomes in companion animals. This thesis also demonstrates the potential of cats
and dogs as model systems in which to examine the role of vitamin D in human health
Evaluation of serum 25‐hydroxyvitamin D concentrations in a heterogeneous canine ICU population
Image segmentation of micro-TIG battery welds
Inspection of cell-to-tab welds in module assembly for battery pack is one the most critical processes in the production of battery packs for transportation electrification. A procedure suitable for the segmentation of weld images on module assembly lines is proposed to separate them into weld and tab regions. The procedure is centred around identifying the edge of the weld and the convex hull region that includes it. The edge is detected with a fuzzy logic rule-based inference system. The procedure is demonstrated with a set of 71 images that are labelled to establish a comparison reference, the so called ground truth. Particle swarm optimisation is used to find values of the parameter procedure that result in a a local minimum of the mean percent error (MPE). An MPE of 4.25 per cent has been obtained
Closure to “Calibration Procedures for Rational and USSCS Design Flood Methods” by G. W. Titmarsh, I. Cordery, and D. H. Pilgrim
- …
