159 research outputs found

    Genetic landscape of autism spectrum disorder in Vietnamese children

    Get PDF
    Autism spectrum disorder (ASD) is a complex disorder with an unclear aetiology and an estimated global prevalence of 1%. However, studies of ASD in the Vietnamese population are limited. Here, we first conducted whole exome sequencing (WES) of 100 children with ASD and their unaffected parents. Our stringent analysis pipeline was able to detect 18 unique variants (8 de novo and 10 ×-linked, all validated), including 12 newly discovered variants. Interestingly, a notable number of X-linked variants were detected (56%), and all of them were found in affected males but not in affected females. We uncovered 17 genes from our ASD cohort in which CHD8, DYRK1A, GRIN2B, SCN2A, OFD1 and MDB5 have been previously identified as ASD risk genes, suggesting the universal aetiology of ASD for these genes. In addition, we identified six genes that have not been previously reported in any autism database: CHM, ENPP1, IGF1, LAS1L, SYP and TBX22. Gene ontology and phenotype-genotype analysis suggested that variants in IGF1, SYP and LAS1L could plausibly confer risk for ASD. Taken together, this study adds to the genetic heterogeneity of ASD and is the first report elucidating the genetic landscape of ASD in Vietnamese children

    Cost effectiveness and sustainability of sanitation options: A case study of South Can Tho - Technical Report

    Full text link
    The Institute for Sustainable Futures (ISF), from the University of Technology Sydney, in collaboration with Can Tho University (CTU) and Can Tho Water Supply and Sewerage Company (WSSC) completed a 2-year collaborative research project assessing the wastewater infrastructure options for Can Tho City. The comparison of alternatives was made on the basis of cost-effectiveness and on the relative sustainability of the options, as determined through a participatory stakeholder sustainability assessment process with several government agencies in Can Tho

    Nutritional status, dietary quality and eating disturbance issues among people with dementia in Vietnam: evidence of a cross-sectional study

    Get PDF
    \ua9 The Author(s) 2024.Background: Due to cognitive impairments, people with dementia (PWD) often have difficulties in eating and drinking. This study aimed to assess the nutritional status, dietary quality and eating disturbance issues among PWD in Vietnam. Methods: We conducted a cross-sectional study at the Vietnamese National Geriatric Hospital from April to December 2022. We used Mini-Mental State Exam (MMSE) to classify the severity levels of dementia. Mini Nutritional Assessment (MNA), 24-hour recall, eating disturbance questionnaires, and anthropometric indicators were used to evaluate the nutritional status, dietary quality, and eating disorders of study subjects. Results: Overall, among 63 study participants, 74.6 per cent of PWD were at risk of or having malnutrition. By dementia classification according to MMSE scale, people with moderate and severe dementia accounted for 53.3 per cent of those who met the recommended energy levels, compared to 42.4 per cent of people with mild dementia and normal people. In the above two groups, around three per cent of participants reached the recommended amount of fibre. Calcium (50–70%), vitamin A (80–90%), and D (90%) were found to be the most severe deficiency forms of minerals and vitamins in both male and female participants. The majority of participants (90.5%) had at least one form of eating disorders with the most frequent issue being appetite changes (76.2%) and swallowing issues (50.8%). Conclusions: PWD in our sample frequently experienced malnutrition, a lack of essential nutrients, difficulties swallowing, changes in eating habits and appetite. It is neccesary to early screen and assess nutritional status and swallowing disturbance in PWD, and instruct their caregivers to prepare nutritious meals for them

    Symbolic Partial-Order Execution for Testing Multi-Threaded Programs

    Full text link
    We describe a technique for systematic testing of multi-threaded programs. We combine Quasi-Optimal Partial-Order Reduction, a state-of-the-art technique that tackles path explosion due to interleaving non-determinism, with symbolic execution to handle data non-determinism. Our technique iteratively and exhaustively finds all executions of the program. It represents program executions using partial orders and finds the next execution using an underlying unfolding semantics. We avoid the exploration of redundant program traces using cutoff events. We implemented our technique as an extension of KLEE and evaluated it on a set of large multi-threaded C programs. Our experiments found several previously undiscovered bugs and undefined behaviors in memcached and GNU sort, showing that the new method is capable of finding bugs in industrial-size benchmarks.Comment: Extended version of a paper presented at CAV'2

    A Multidomain Intervention Program for Older People with Dementia: A Pilot Study

    Get PDF
    Background: Multidomain interventions have been shown to be effective in improving cognition, quality of life, reducing neuropsychiatric symptoms and delaying progression of functional impairment or disability in dementia patients. To investigate the multidomain intervention in other populations and diverse cultural and geographical settings, this pilot study will assess the feasibility of a multidomain intervention for older people with dementia in nursing homes in Vietnam. Methods: Participants will be randomized into two equal groups, to receive either a multidomain intervention (intervention group) or regular health advice (control group). The intervention will include physical, cognitive, and social interventions as well as management of metabolic and vascular risk factors. We will hypothesize that the multidomain intervention will be feasible in Vietnam, and participants who receive the intervention will show improvement in quality of life, behaviors, functional ability, cognitive function, sleep, and in reduction of falls, use of healthcare services, and death rate compared to those in the control group during the 6 months intervention period and after the 6 months extended follow-up. Discussion: This is the first study to evaluate the feasibility of a multidomain intervention program for older people with dementia in nursing homes in Vietnam. The results from the trial will inform clinicians and the public of the possibility of comprehensive treatment beyond simply drug treatments for dementia. This paves the way for further studies to evaluate the long-term effects of multidomain interventions in dementia patients. Furthermore, the research results will provide information on the effectiveness of multidomain interventions which will inform policy development on dementia. Trial Registration: The trial is registered with ClinicalTrials.gov identifier: NCT04948450 on 02/07/2021

    Indicators for assessing the quality of refractive error care

    Full text link
    Significance: Quality refractive error care is essential for reducing vision impairment. Quality indicators and standardized approaches for assessing the quality of refractive error care need to be established. Purpose: This study aimed to develop a set of indicators for assessing the quality of refractive error care and test their applicability in a real-world setting using unannounced standardized patients (USPs). Methods: Patient outcomes and three quality of refractive error care (Q.REC) indicators (1, optimally prescribed spectacles; 2, adequately prescribed spectacles; 3, vector dioptric distance) were developed using existing literature, refraction training standards, and consulting educators. Twenty-one USPs with various refractive errors were trained to visit optical stores across Vietnam to have a refraction, observe techniques, and order spectacles. Spectacles were assessed against each Q.REC indicator and tested for associations with vision and comfort. Results: Overall, 44.1% (184/417) of spectacles provided good vision and comfort. Of the spectacles that met Q.REC indicators 1 and 2, 62.5 and 54.9%, respectively, provided both good vision and comfort. Optimally prescribed spectacles (indicator 1) were significantly more likely to provide good vision and comfort independently compared with spectacles that did not meet any indicator (good vision: 94.6 vs. 85.0%, P =.01; comfortable: 66.1 vs. 36.3%, P <.01). Adequately prescribed spectacles (indicator 2) were more likely to provide good comfort compared with spectacles not meeting any indicator (57.7 vs. 36.3%, P <.01); however, vision outcomes were not significantly different (85.9 vs. 85.0%, P =.90). Good vision was associated with a lower mean vector dioptric distance (P <.01) but not with comfort (P =.52). Conclusions: The optimally prescribed spectacles indicator is a promising approach for assessing the quality of refractive error care without additional assessments of vision and comfort. Using USPs is a practical approach and could be used as a standardized method for evaluating the quality of refractive error care

    Electrochemical sensor based on epoxy-functionalized BEA nanozeolite and graphene oxide modified glassy carbon electrode for bisphenol E determination

    Get PDF
    An epoxy-functionalized beta type nanozeolite (BEA)/graphene oxide nanocomposite modified glassy carbon electrode (GCE/BEA/APTMS/GA/GO/NF) has been created for the differential pulse voltammetric determination of bisphenol E (BPE). The modified electrode presented an enhanced current response in comparison with bare GCE. A linear dependence of anodic peak current (Ip) and scan rate (ν) was observed, which showed that the electrochemical process was adsorption-controlled. Differential pulse voltammetry (DPV) was employed and optimized for the sensitive determination of BPE. Under the optimized conditions, the anodic peak current was linearly proportional to BPE concentration in the range between 0.07 and 4.81 µM, with a correlation coefficient of 0.995 and limit of detection 0.056 μM (S/N = 3). The electrode showed good repeatability and storage stability, and a low response to interfering compounds. Comparison was made to the determination of bisphenol A. To confirm the electrode analytical performance, recovery tests were performed, and deviations lower than 10% were found. The BEA zeolite-GO nanocomposite proved to be a promising sensing platform for bisphenol determination. Graphical abstract: [Figure not available: see fulltext.]
    corecore