1,044 research outputs found
Imaging the Effects of Oxygen Saturation Changes in Voluntary Apnea and Hyperventilation on Susceptibility-Weighted Imaging
BACKGROUND AND PURPOSE: Cerebrovascular oxygenation changes during respiratory challenges have clinically important implications for brain function, including cerebral autoregulation and the rate of brain metabolism. SWI is sensitive to venous oxygenation level by exploitation of the magnetic susceptibility of deoxygenated blood. We assessed cerebral venous blood oxygenation changes during simple voluntary breath-holding (apnea) and hyperventilation by use of SWI at 3T.
MATERIALS AND METHODS: We performed SWI scans (3T; acquisition time of 1 minute, 28 seconds; centered on the anterior commissure and the posterior commissure) on 10 healthy male volunteers during baseline breathing as well as during simple voluntary hyperventilation and apnea challenges. The hyperventilation and apnea tasks were separated by a 5-minute resting period. SWI venograms were generated, and the signal changes on SWI before and after the respiratory stress tasks were compared by means of a paired Student t test.
RESULTS: Changes in venous vasculature visibility caused by the respiratory challenges were directly visualized on the SWI venograms. The venogram segmentation results showed that voluntary apnea decreased the mean venous blood voxel number by 1.6% (P < .0001), and hyperventilation increased the mean venous blood voxel number by 2.7% (P < .0001). These results can be explained by blood CO2 changes secondary to the respiratory challenges, which can alter cerebrovascular tone and cerebral blood flow and ultimately affect venous oxygen levels.
CONCLUSIONS: These results highlight the sensitivity of SWI to simple and noninvasive respiratory challenges and its potential utility in assessing cerebral hemodynamics and vasomotor responses
Tempo and mode of performance evolution across multiple independent origins of adhesive toe pads in lizards
Understanding macroevolutionary dynamics of trait evolution is an important endeavor in evolutionary biology. Ecological opportunity can liberate a trait as it diversifies through trait space, while genetic and selective constraints can limit diversification. While many studies have examined the dynamics of morphological traits, diverse morphological traits may yield the same or similar performance and as performance is often more proximately the target of selection, examining only morphology may give an incomplete understanding of evolutionary dynamics. Here, we ask whether convergent evolution of pad‐bearing lizards has followed similar evolutionary dynamics, or whether independent origins are accompanied by unique constraints and selective pressures over macroevolutionary time. We hypothesized that geckos and anoles each have unique evolutionary tempos and modes. Using performance data from 59 species, we modified Brownian motion (BM) and Ornstein–Uhlenbeck (OU) models to account for repeated origins estimated using Bayesian ancestral state reconstructions. We discovered that adhesive performance in geckos evolved in a fashion consistent with Brownian motion with a trend, whereas anoles evolved in bounded performance space consistent with more constrained evolution (an Ornstein–Uhlenbeck model). Our results suggest that convergent phenotypes can have quite distinctive evolutionary patterns, likely as a result of idiosyncratic constraints or ecological opportunities
Sequences
Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145297/1/cpmib0500.pd
A novel multiparametric approach to 3D quantitative MRI of the brain
Magnetic Resonance properties of tissues can be quantified in several respects: relaxation processes, density of imaged nuclei, magnetism of environmental molecules, etc. In this paper, we propose a new comprehensive approach to obtain 3D high resolution quantitative maps of arbitrary body districts, mainly focusing on the brain. The theory presented makes it possible to map longitudinal (R1), pure transverse (R2) and free induction decay (R2 ) rates, along with proton density (PD) and magnetic susceptibility (χ), from a set of fast acquisition sequences in steady-state that are highly insensitive to flow phenomena. A novel denoising scheme is described and applied to the acquired datasets to enhance the signal to noise ratio of the derived maps and an information theory approach compensates for biases from radio frequency (RF) inhomogeneities, if no direct measure of the RF field is available. Finally, the results obtained on sample brain scans of healthy controls and multiple sclerosis patients are presented and discussed
On the averaging of cardiac diffusion tensor MRI data: the effect of distance function selection
Diffusion tensor magnetic resonance imaging (DT-MRI) allows a unique insight into the microstructure of highly-directional tissues. The selection of the most proper distance function for the space of diffusion tensors is crucial in enhancing the clinical application of this imaging modality. Both linear and nonlinear metrics have been proposed in the literature over the years. The debate on the most appropriate DT-MRI distance function is still ongoing. In this paper, we presented a framework to compare the Euclidean, affine-invariant Riemannian and log-Euclidean metrics using actual high-resolution DT-MRI rat heart data. We employed temporal averaging at the diffusion tensor level of three consecutive and identically-acquired DT-MRI datasets from each of five rat hearts as a means to rectify the background noise-induced loss of myocyte directional regularity. This procedure is applied here for the first time in the context of tensor distance function selection. When compared with previous studies that used a different concrete application to juxtapose the various DT-MRI distance functions, this work is unique in that it combined the following: (i) Metrics were judged by quantitative - rather than qualitative – criteria, (ii) the comparison tools were non-biased, (iii) a longitudinal comparison operation was used on a same-voxel basis. The statistical analyses of the comparison showed that the three DT-MRI distance functions tend to provide equivalent results. Hence, we came to the conclusion that the tensor manifold for cardiac DT-MRI studies is a curved space of almost zero curvature. The signal to noise ratio dependence of the operations was investigated through simulations. Finally, the “swelling effect” occurrence following Euclidean averaging was found to be too unimportant to be worth consideration
In ovo serial skeletal muscle diffusion tractography of the developing chick embryo using DTI: feasibility and correlation with histology
Abstract
Background
Magnetic resonance imaging is a noninvasive method of evaluating embryonic development. Diffusion tensor imaging (DTI), based on the directional diffusivity of water molecules, is an established method of evaluating tissue structure. Yet embryonic motion degrades the in vivo acquisition of long-duration DTI. We used a dual-cooling technique to avoid motion artifact and aimed to investigate whether DTI can be used to monitor chick embryonic skeletal muscle development in ovo, and to investigate the correlation between quantitative DTI parameters fractional anisotropy (FA) and fiber length and quantitative histologic parameters fiber area percentage (FiberArea%) and limb length.
Results
From 84 normally developing chick embryos, 5 were randomly chosen each day from incubation days 5 to 18 and scanned using 3.0 Tesla magnetic resonance imaging. A dual-cooling technique is used before and during imaging. Eggs were cracked for making histological specimen after imaging. 3 eggs were serially imaged from days 5 to 18. We show that skeletal muscle fibers can be tracked in hind limb in DTI beginning with incubation day 8. Our data shows a good positive correlation between quantitative DTI and histologic parameters (FA vs FiberArea%: r= 0.943, p\u3c0.0001; Fiber_length vs Limb_length: r=0.974, p\u3c0.0001). The result of tracked fibers in DTI during incubation corresponds to the development of chick embryonic skeletal muscle as reported in the literature.
Conclusion
Diffusion tensor imaging can provide a noninvasive means of evaluating skeletal muscle development in ovo
Preface
Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145289/1/cpmipref.pd
Motion Compensation Along All Three Different Directions
This unit addresses how one can deal with phase perturbations that arise due to the presence of motion. Techniques to reduce or remove their associated artifacts are explained in detail. Artifacts due to phase changes that come from the read gradient, from the slice select gradient and from the phase encoding gradient are also discussed.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145397/1/cpmib0702.pd
Magnetic Moment of a Spin, Its Equation of Motion, and Precession
This unit discusses the basic spin properties of the proton. The motion of a spin in an magnetic field that give rise to magnetic moment, is also discussed. The key to grasping much of MRI lies in understanding the concept of precession. Famous Bloch equation that basically leads to the description of the precession of a spin in the presence of an external magnetic field is also explained.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145243/1/cpmib0101.pd
Signal Detection
The bulk magnetization represents the equilibrium value of the magnetization when all spins have aligned themselves parallel to the main field. When this magnetization is tipped into the transverse plane, it precesses about the main field. This precession generates a changing flux through the face of an appropriately placed coil inducing an electromotive force (emf) in the coil. The measured signal is proportional to the induced emf. This unit discusses the basic physics behind detecting MR signal. The process of calculating induced emf based on Faradays law of induction is explained.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145226/1/cpmib0201.pd
- …
