392 research outputs found

    Sex differences in the course of implantable cardioverter defibrillator concerns (Results from the Danish national DEFIB-WOMEN study)

    Get PDF
    OBJECTIVE: The implantable cardioverter defibrillator (ICD) is used to treat malignant ventricular arrhythmias. Since 33% of patients experience ICD-related concerns, we examined sex differences in ICD concerns and correlates of ICD concerns during 24 months of follow-up after implantation of an ICD.METHODS: Patients from the DEFIB-WOMEN study (n = 1515; 81.6% male patients) completed questionnaires on ICD concerns, anxiety, depression, and Type D personality at five measure points (baseline, 3-, 6-, 12- and 24-months post-implantation).RESULTS: Male patients scored on average 7.0 (6.8) points on ICD concerns at the time of implantation and female patients scored on average 10.5 (8.2) points. We found statistically significant sex differences in ICD concerns at all measurement points, with female patients scoring 2.77 points (8.7% of the maximum score of 32) higher than male patients. ICD concerns decreased in both sexes the first 6 months and then levelled out. For both sexes, ICD concerns at baseline were significantly correlated with ICD concerns at 24-months follow-up. Anxiety at baseline was correlated with ICD concerns in female patients, while depression at baseline and at least one experienced shock correlated with ICD concerns in male patients.CONCLUSION: Female patients reported more ICD concerns at all measurement points compared to male patients, but for both sexes ICD concerns decreased in the first 6 months. ICD shock, anxiety, depression, and ICD concerns at baseline were correlates of ICD concerns at 24-months follow-up.</p

    New onset anxiety and depression in patients with an implantable cardioverter defibrillator during 24 months of follow-up (data from the national DEFIB-WOMEN study)

    Get PDF
    OBJECTIVE: To examine the cumulative incidence of and covariates' association with new onset anxiety and depression in implantable cardioverter defibrillator (ICD) patients during 24 months of follow-up in patients without depression and anxiety at implant.METHODS: Patients (n = 1040; 155 (14.9%) women; mean age: 64.2 ± 10.6) with a first-time ICD enrolled in the national, multi-center prospective observational DEFIB-WOMEN study comprised the study cohort. We obtained information on demographic and clinical data from the Danish Pacemaker and ICD Register.RESULTS: During 24 months of follow-up, 138 (14.5%) patients developed new onset anxiety and 109 (11.3%) new onset depression. Age ≥ 60 [HR:0.60;95%CI:0.40-0.90] and an anxiety score between 3 and 4 [HR:2.85; 95%CI:1.71-4.75] and 5-7 [HR:5.97; 95%CI:3.77-9.45] on the Hospital Anxiety and Depression Scale (HADS) were associated with different hazards of new onset anxiety during follow-up. Age ≥ 60 [HR:0.62;95%CI:0.42-0.93] and a HADS depression score between 3 and 4 [HR:2.99;95%CI:1.80-4.95] and 5-7 [HR:6.45; 95%CI:4.12-10.10] were associated with different hazards of new onset depression.CONCLUSION: During 24 months of follow-up, respectively 14.5% and 11.3% of patients developed new onset anxiety and depression, suggesting that screening patients at several timepoints, and in particular those with even minimally elevated HADS scores at baseline, may be warranted to identify patients at risk for poor health outcomes.</p

    Significant regional variation in use of implantable cardioverter-defibrillators in Denmark

    Get PDF
    AIMS: Implantable cardioverter-defibrillator (ICD) treatment prevents sudden cardiac death in high-risk patients. This study examined geographical variation in ICD implantation rates in Denmark and potential causes of variation.METHODS AND RESULTS: We obtained numbers of ICD implantations in the 5 Danish regions and 98 municipalities during 2007-13 from the Danish Pacemaker and ICD Registry. Standardized implantation rates (SIRs) were computed as ICD implantations per 1 000 000 person-years, and age- and gender-standardized to the Danish population. We examined associations of the municipal SIR with mean age and Charlson Comorbidity Index score of ICD recipients, percentage of implantations with primary prophylactic indication, and distance from patient residency to ICD implanting centre. Based on 7192 ICD implantations, the nationwide SIR was 186 [95% confidence interval (CI) 182-190], ranging from 170 (95% CI 158-183) in the North Denmark Region to 206 (95% CI 195-218) in the Region of Zealand. Municipalities with higher patient comorbidity scores, higher percentages of implantations with primary prophylactic indication, and shorter distances to ICD implanting centres, had higher SIRs [differences between SIRs of municipalities in highest and lowest quartiles 22 (95% CI 10-34), 45 (95% CI 33-58), and 35 (95% CI 24-47), respectively]. Regional differences in SIRs decreased over time and had become insignificant during 2011-13.CONCLUSION: Implantable cardioverter-defibrillator implantation rates in Denmark varied significantly between regions but variation decreased during 2007-13. Geographical variation was associated with differences in patient comorbidity score, variation in use of primary prophylactic ICD treatment, and distance to ICD implanting centre.</p

    Effect of implantable cardioverter-defibrillators in patients with non-ischaemic systolic heart failure and concurrent coronary atherosclerosis

    Get PDF
    AIMS: Prophylactic implantable cardioverter‐defibrillators (ICD) reduce mortality in patients with ischaemic heart failure (HF), whereas the effect of ICD in patients with non‐ischaemic HF is less clear. We aimed to investigate the association between concomitant coronary atherosclerosis and mortality in patients with non‐ischaemic HF and the effect of ICD implantation in these patients. METHODS AND RESULTS: Patients were included from DANISH (Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators in Patients with Non‐Ischaemic Systolic Heart Failure on Mortality), randomizing patients to ICD or control. Study inclusion criteria for HF were left ventricular ejection fraction ≤ 35% and increased levels (>200 pg/mL) of N‐terminal pro‐brain natriuretic peptide. Of the 1116 patients from DANISH, 838 (75%) patients had available data from coronary angiogram and were included in this subgroup analysis. We used Cox regression to assess the relationship between coronary atherosclerosis and mortality and the effect of ICD implantation. Of the included patients, 266 (32%) had coronary atherosclerosis. Of these, 216 (81%) had atherosclerosis without significant stenoses, and 50 (19%) had significant stenosis. Patients with atherosclerosis were significantly older {67 [interquartile range (IQR) 61–73] vs. 61 [IQR 54–68] years; P < 0.0001}, and more were men (77% vs. 70%; P = 0.03). During a median follow‐up of 64.3 months (IQR 47–82), 174 (21%) of the patients died. The effect of ICD on all‐cause mortality was not modified by coronary atherosclerosis [hazard ratio (HR) 0.94; 0.58–1.52; P = 0.79 vs. HR 0.82; 0.56–1.20; P = 0.30], P for interaction = 0.67. In univariable analysis, coronary atherosclerosis was a significant predictor of all‐cause mortality [HR, 1.41; 95% confidence interval (CI), 1.04–1.91; P = 0.03]. However, this association disappeared when adjusting for cardiovascular risk factors (age, gender, diabetes, hypertension, smoking, and estimated glomerular filtration rate) (HR 1.05, 0.76–1.45, P = 0.76). CONCLUSIONS: In patients with non‐ischaemic systolic heart failure, ICD implantation did not reduce all‐cause mortality in patients either with or without concomitant coronary atherosclerosis. The concomitant presence of coronary atherosclerosis was associated with increased mortality. However, this association was explained by other risk factors
    corecore