321 research outputs found

    Impact of perioperative infarcts after cardiac surgery

    Get PDF
    Background and Purpose: Brain injury after cardiac surgery is a serious concern for patients and their families. The purpose of this study was to use 3-T fluid attenuated inversion recovery MRI to characterize new and preexisting cerebral ischemic lesions in patients undergoing cardiac surgery and to test whether the accumulation of new ischemic lesions adversely affects cognition. Methods: Digital comparison of before and after fluid attenuated inversion recovery MRI images was performed for 77 cardiac surgery patients. The burden of preexisting versus new ischemic lesions was quantified and compared with the results of baseline and postoperative neuropsychological testing. Results: After surgery, new lesions were identified in 31% of patients, averaging 0.5 lesions per patient (67 mm3 [0.004%] of brain tissue). Patients with preexisting lesions were 10× more likely to receive new lesions after surgery than patients without preexisting lesions. Preexisting ischemic lesions were observed in 64% of patients, averaging 19.4 lesions (1542 mm3 [0.1%] of brain tissue). New lesions in the left hemisphere were significantly smaller and more numerous (29 lesions; median volume, 44 mm3; volume range, 5–404 mm3) than those on the right (10 lesions; median volume, 128 mm3; volume range, 13–1383 mm3), which is consistent with a cardioembolic source of particulate emboli. Overall, the incidence of postoperative cognitive decline was 46% and was independent of whether new lesions were present. Conclusions: New lesions after cardiac surgery added a small (≈4%) contribution to the burden of preexisting cerebrovascular disease and did not seem to affect cognitive function

    Tensor based multichannel reconstruction for breast tumours identification from DCE-MRIs

    Get PDF
    A new methodology based on tensor algebra that uses a higher order singular value decomposition to perform three-dimensional voxel reconstruction from a series of temporal images obtained using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is proposed. Principal component analysis (PCA) is used to robustly extract the spatial and temporal image features and simultaneously de-noise the datasets. Tumour segmentation on enhanced scaled (ES) images performed using a fuzzy C-means (FCM) cluster algorithm is compared with that achieved using the proposed tensorial framework. The proposed algorithm explores the correlations between spatial and temporal features in the tumours. The multi-channel reconstruction enables improved breast tumour identification through enhanced de-noising and improved intensity consistency. The reconstructed tumours have clear and continuous boundaries; furthermore the reconstruction shows better voxel clustering in tumour regions of interest. A more homogenous intensity distribution is also observed, enabling improved image contrast between tumours and background, especially in places where fatty tissue is imaged. The fidelity of reconstruction is further evaluated on the basis of five new qualitative metrics. Results confirm the superiority of the tensorial approach. The proposed reconstruction metrics should also find future applications in the assessment of other reconstruction algorithms

    Study of hadronic event-shape variables in multijet final states in pp collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Search for new physics in the multijet and missing transverse momentum final state in proton-proton collisions at √s=8 Tev

    Get PDF
    Peer reviewe

    Measurement of Higgs boson production and properties in the WW decay channel with leptonic final states

    Get PDF
    Peer reviewe

    Constraints on parton distribution functions and extraction of the strong coupling constant from the inclusive jet cross section in pp collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Study of double parton scattering using W+2-jet events in proton-proton collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Measurements of the tt¯ charge asymmetry using the dilepton decay channel in pp collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel–Titanium Stent: Feasibility and Safety Porcine Trial

    Get PDF
    We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel–titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted
    corecore