1,275 research outputs found
Recommended from our members
Characteristics and influence of biosmoke on the fine-particle ionic composition measured in Asian outflow during the Transport and Chemical Evolution Over the Pacific (TRACE-P) experiment
First observation of psi(2S)-->K_S K_L
The decay psi(2S)-->K_S K_L is observed for the first time using psi(2S) data
collected with the Beijing Spectrometer (BESII) at the Beijing Electron
Positron Collider (BEPC); the branching ratio is determined to be
B(psi(2S)-->K_S K_L) = (5.24\pm 0.47 \pm 0.48)\times 10^{-5}. Compared with
J/psi-->K_S K_L, the psi(2S) branching ratio is enhanced relative to the
prediction of the perturbative QCD ``12%'' rule. The result, together with the
branching ratios of psi(2S) decays to other pseudoscalar meson pairs
(\pi^+\pi^- and K^+K^-), is used to investigate the relative phase between the
three-gluon and the one-photon annihilation amplitudes of psi(2S) decays.Comment: 5 pages, 4 figures, 2 tables, submitted to Phys. Rev. Let
Study of psi(2S) decays to X J/psi
Using J/psi -> mu^+ mu^- decays from a sample of approximately 4 million
psi(2S) events collected with the BESI detector, the branching fractions of
psi(2S) -> eta J/psi, pi^0 pi^0 J/psi, and anything J/psi normalized to that of
psi(2S) -> pi^+ pi^- J/psi are measured. The results are B(psi(2S) -> eta
J/psi)/B(psi(2S) -> pi^+ pi^- J/psi) = 0.098 \pm 0.005 \pm 0.010, B(psi(2S) ->
pi^0 pi^0 J/psi)/B(psi(2S) -> pi^+ pi^- J/psi) = 0.570 \pm 0.009 \pm 0.026, and
B(psi(2S) -> anything J/psi)/B(psi(2S) -> pi^+ pi^- J/psi) = 1.867 \pm 0.026
\pm 0.055.Comment: 13 pages, 8 figure
Wavelength-scale stationary-wave integrated Fourier-transform spectrometry
Spectrometry is a general physical-analysis approach for investigating
light-matter interactions. However, the complex designs of existing
spectrometers render them resistant to simplification and miniaturization, both
of which are vital for applications in micro- and nanotechnology and which are
now undergoing intensive research. Stationary-wave integrated Fourier-transform
spectrometry (SWIFTS)-an approach based on direct intensity detection of a
standing wave resulting from either reflection (as in the principle of colour
photography by Gabriel Lippmann) or counterpropagative interference
phenomenon-is expected to be able to overcome this drawback. Here, we present a
SWIFTS-based spectrometer relying on an original optical near-field detection
method in which optical nanoprobes are used to sample directly the evanescent
standing wave in the waveguide. Combined with integrated optics, we report a
way of reducing the volume of the spectrometer to a few hundreds of cubic
wavelengths. This is the first attempt, using SWIFTS, to produce a very small
integrated one-dimensional spectrometer suitable for applications where
microspectrometers are essential
Measurement of the Branching Fraction of J/psi --> pi+ pi- pi0
Using 58 million J/psi and 14 million psi' decays obtained by the BESII
experiment, the branching fraction of J/psi --> pi+ pi- pi0 is determined. The
result is (2.10+/-0.12)X10^{-2}, which is significantly higher than previous
measurements.Comment: 9 pages, 8 figures, RevTex
First Measurements of eta_c Decaying into K^+K^-2(pi^+pi^-) and 3(pi^+pi^-)
The decays of eta_c to K^+K^-2(pi^+pi^-) and 3(pi^+pi^-) are observed for the
first time using a sample of 5.8X10^7 J/\psi events collected by the BESII
detector. The product branching fractions are determined to be B(J/\psi-->gamma
eta_c)*B(eta_c-->K^+K^-pi^+pi^-pi^+pi^-)=(1.21+-0.32+-
0.23)X10^{-4}, and (J/\psi-->gamma eta_c)*
B(eta_c-->pi^+pi^-pi^+pi^-pi^+pi^-)= (2.59+-0.32+-0.48)X10^{-4}. The upper
limit for eta_c-->phi pi^+pi^-pi^+pi^- is also obtained as B(J/\psi-->gamma
eta_c)*B(eta_c--> phi pi^+pi^-pi^+pi^-)< 6.03 X10^{-5} at the 90% confidence
level.Comment: 11 pages, 4 figure
Search for K_S K_L in psi'' decays
K_S K_L from psi'' decays is searched for using the psi'' data collected by
BESII at BEPC, the upper limit of the branching fraction is determined to be
B(psi''--> K_S K_L) < 2.1\times 10^{-4} at 90% C. L. The measurement is
compared with the prediction of the S- and D-wave mixing model of the
charmonia, based on the measurements of the branching fractions of J/psi-->K_S
K_L and psi'-->K_S K_L.Comment: 5 pages, 1 figur
Resonances in and
A partial wave analysis is presented of and
from a sample of 58M events in the BES II detector. The
is observed clearly in both sets of data, and parameters of the
Flatt\' e formula are determined accurately: (stat)
(syst) MeV/c, MeV/c, . The data also exhibit a strong peak
centred at MeV/c. It may be fitted with and a
dominant signal made from interfering with a smaller
component. There is evidence that the signal is
resonant, from interference with . There is also a state in with MeV/c and
MeV/c; spin 0 is preferred over spin 2. This state, , is
distinct from . The data contain a strong peak due to
. A shoulder on its upper side may be fitted by interference
between and .Comment: 17 pages, 6 figures, 1 table. Submitted to Phys. Lett.
Eine neue Sensortechnik zur Messung von elektrischen Potentialprofilen der menschlichen Haut anAkupunkturpunkten
Introduction: From an electro-physiological point of view human skin shows an inhomogeneous pattern regarding its electrical resistance: in certain areas a decreased electrical resistance can be observed. It has been postulated that these areas correspond to acupuncture points. Subsequently, devices have been developed as detectors for acupuncture points which are used for diagnosis and treatment in acupuncture. However, most of these devices are inconsistent: they show a remarkable inaccuracy in their measurements and are poorly evaluated. Further analyses have shown that the measuring pens often used are subject to various disturbances such as pressure, angle of measurement, humidity of the skin, different thickness of stratum corneum of the skin and external disturbances such as temperature and humidity in the measuring room. Material and Methods: We present a new device for standardized measuring of electrical skin resistance. It consists of a field of 64 electrodes (measuring array) on a surface of 60 x 60 mm(2) and a distance of 8 mm between electrodes. For a more precise spatial resolution a field of 32 electrodes on a surface of 3.5 x 3.5 mm(2) with a distance of 0.65 mm is available. A high, precise, temporal resolution of electric potentials in human skin is realized by fast scanning of the electrodes. Technical details are described. Conclusions: First analyses of collected data show that reliable and valid measurements are possible. Using this device in a controlled and blinded study design will help elucidate the issue of altered skin resistance at acupuncture points and clarify if this phenomenon is unique at acupuncture points
- …
