52 research outputs found
Acceptability of intrapartum ultrasound by mothers in an African population
Intrapartum ultrasound is gaining high acceptance by many women as another method for assessing labour progression. Despite growing evidence of the effectiveness of ultrasound in labour, the acceptance of intrapartum ultrasound has not been previously investigated in black Africans. This study aimed to determine women’s acceptance of intrapartum ultrasound and their preference for transperineal ultrasound or digital vaginal examination (digital VE) in Ghana. An analytical cross-sectional study was conducted among mothers who had had both digital VE and transperineal ultrasound during labour in a tertiary hospital. Information about their sociodemographic characteristics, experience with, and preference for ultrasound or digital VE in labour using a pretested structured questionnaire was obtained. Their experiences were categorised as ‘tolerable, ‘quite uncomfortable’ or ‘very uncomfortable’. Categorical variables were compared using Fisher’s exact test. A p value < 0.05 was considered statistically significant. Altogether, 196 women were recruited into the study. The mean age of the women was 26.7 years (standard deviation, 4.6 years). Nearly half (47%) of the women had never delivered before. Significantly more women considered transperineal ultrasound to be more tolerable than digital VE (66% vs. 40%; p < 0.001). Almost all the women (97.5%) described their experience with transperineal ultrasound to be better than digital VE, and would choose transperineal ultrasound over digital VE in the future (98.5% vs. 1.5%; p < 0.001). The findings of this study are comparable to those of other related studies reported recently. This research confirms high acceptance of ultrasound in labour by mothers from different countries and across continents, implying that cultural differences do not influence women’s responses to and interest in intrapartum ultrasound. Most women found ultrasound in labour to be more tolerable than digital VE. Whenever possible, transperineal ultrasound should be provided as an alternative to digital VE during labour.N/
Intrapartum ultrasound assessment of cervical dilatation and its value in detecting active labor.
Introduction We aimed to examine the agreement between ultrasound and digital vaginal examination in assessing cervical dilatation in an African population and to assess the value of ultrasound in detecting active labor. Method A cross-sectional study was conducted in a teaching hospital in Ghana between April and September of 2016. Anterior–posterior and transverse diameters of cervical dilatation were measured with ultrasound and the mean value was compared with digital vaginal examination in 195 women in labor. Agreement between methods was examined with correlation coefficients and with Bland–Altman plots. Active labor was defined when cervix was dilated ≥ 4 cm with vaginal examinations. ROC curve analysis was conducted on the diagnostic performance of ultrasound in detecting active labor. Results Data were analyzed in 175 out of 195 (90%) cases where ultrasound could clearly visualize the cervix. The remaining 20 cases were all determined by digital vaginal examination as advanced cervical dilatation (≥ 8 cm), advanced head station (≥ + 2), and with ruptured membranes. The Pearson correlation coefficient (r) was 0.78 (95% CI 0.72–0.83) and the intra-class correlation coefficient was 0.76 (95% CI 0.69–0.81). Bland–Altman analysis obtained a mean difference of − 0.03 cm (95% CI − 0.18 to 0.12) with zero included in the CI intervals, indicating no significant difference between methods. Limits of agreement were from − 2.01 to 1.95 cm. Ultrasound predicted active labor with 0.87 (95% CI 0.75–0.99) as the area under the ROC curve. Conclusion Ultrasound measurements showed good agreement with digital vaginal examinations in assessing cervical dilatation during labor and ultrasound may be used to detect active labor.N/
The effectiveness of intrapartum ultrasonography in assessing cervical dilatation, head station and position: A systematic review and meta-analysis
The objective of this review was to assess the effectiveness of intrapartum ultrasonography in measuring cervical dilatation, head station and position. Electronic literature searches were carried out of MEDLINE, CINAHL, and Web of Knowledge, plus manual reference list checks of all relevant articles. All published prospective studies comparing intrapartum ultrasonography with digital VE in the determination of cervical dilatation, head station and position were then evaluated for the success rate and level of agreement between ultrasonography and digital VE. Ultrasonography had higher success rate than digital VE in the determination of fetal head position, with a statistically significant difference in the first stage of labour. Second, although the successful determination of cervical dilatation was in favour of digital VE, the difference was not statistically significant. In addition, there was high agreement between ultrasound and digital VE findings on cervical dilatation. Lastly, a significant but moderate correlation between digital VE and ultrasound methods was found in the assessment of fetal head station. However, no meta-analysis could be done for the fetal head station due to the methodological differences between ultrasound anatomical landmarks and that of digital VE. The findings suggest that ultrasonography is superior to digital VE in the assessment of fetal head position, but has moderate correlation with digital VE in the assessment of head station. It also showed high agreement with digital VE in the assessment of cervical dilatation with no statistically significant difference in terms of success rate
In emergency department patients requiring resuscitation room care, can Renal Resistive Index measurements predict the development of acute kidney injury?
Ventilatory muscle strength, diaphragm thickness and pulmonary function in world-class powerlifters.
Resistance training activates the ventilatory muscles providing a stimulus similar to ventilatory muscle training. We examined the effects of elite powerlifting training upon ventilatory muscle strength, pulmonary function and diaphragm thickness in world-class powerlifters (POWER) and a control group (CON) with no history of endurance or resistance training, matched for age, height and body mass
Sonographic parameters for diagnosing fetal head engagement during labour.
The purpose of this study was to investigate the diagnostic performance of the head–perineum distance, angle of progression, and the head–symphysis distance as intrapartum ultrasound parameters in the determination of an engaged fetal head. Two hundred and one women in labour underwent both ultrasound and digital vaginal examination in the estimation of fetal head station. The transperineal ultrasound measured head–perineum distance, angle of progression, and head–symphysis distance for values correlating with digital vaginal examination head station. Using station 0 as the minimum level of head engagement, correlating cutoff values for head–perineum distance, angle of progression, and head–symphysis distance were obtained. Receiver operating characteristics were used in determining the diagnostic performance of these cut-off values for the detection of fetal head engagement. With head–perineum distance of 3.6 cm the sensitivity and specificity of sonographic determination of engaged fetal head were 78.7 and 72.3%, respectively. A head–symphysis distance of 2.8 cm also had sensitivity and specificity of 74.5 and 70.8%, respectively, in determining engagement, whilst an angle of progression of 101 was consistent with engagement by digital vaginal examination with 68.1% sensitivity and 68.2% specificity. Ultrasound shows high diagnostic performance in determining engaged fetal head at a head–perineum distance of 3.6 cm, head–symphysis distance of 2.8 cm, and angle of progression of 101.N/
Particle Export Fluxes in the Southern Ocean: Importance of Nonheterotrophic Processes in POC Flux Attenuation
The ocean contributes to regulating atmospheric CO2 levels via the biological carbon pump (BCP). One critical aspect of the BCP is the depth at which sinking particulate organic carbon (POC) remineralizes in the mesopelagic zone (200–1,000 m). In the Southern Ocean, the circulation is such that the products generated from POC remineralization may have drastically different fates depending on (a) the latitude at which sinking particulate material is produced and (b) the depth at which its remineralization occurs. Here, we assess latitudinal and depth variations of POC export marine aggregate abundance and composition in the Southeast Pacific sector of the Southern Ocean. We show changes in flux attenuation depth horizons in the upper mesopelagic in the subantarctic zone. These correspond to rapid particle accumulation below the depth of the euphotic zone followed by abrupt export. We believe that such rapid changes may be linked to diatom life cycles, including resting cell and spore formation and resulting changes in particle sinking velocities rather than attenuation due to heterotrophic degradation or solubilization in the upper mesopelagic zone. We further discuss the occurrence of such features in the Southern Ocean and at the global scale. Our results highlight the importance of alternative flux attenuation processes, such as sudden changes in particles sinking velocities, in explaining variability in organic carbon sequestration by the ocean's BCP
Length of carotid stenosis predicts peri-procedural stroke or death and restenosis in patients randomized to endovascular treatment or endarterectomy.
BACKGROUND: The anatomy of carotid stenosis may influence the outcome of endovascular treatment or carotid endarterectomy. Whether anatomy favors one treatment over the other in terms of safety or efficacy has not been investigated in randomized trials. METHODS: In 414 patients with mostly symptomatic carotid stenosis randomized to endovascular treatment (angioplasty or stenting; n = 213) or carotid endarterectomy (n = 211) in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), the degree and length of stenosis and plaque surface irregularity were assessed on baseline intraarterial angiography. Outcome measures were stroke or death occurring between randomization and 30 days after treatment, and ipsilateral stroke and restenosis ≥50% during follow-up. RESULTS: Carotid stenosis longer than 0.65 times the common carotid artery diameter was associated with increased risk of peri-procedural stroke or death after both endovascular treatment [odds ratio 2.79 (1.17-6.65), P = 0.02] and carotid endarterectomy [2.43 (1.03-5.73), P = 0.04], and with increased long-term risk of restenosis in endovascular treatment [hazard ratio 1.68 (1.12-2.53), P = 0.01]. The excess in restenosis after endovascular treatment compared with carotid endarterectomy was significantly greater in patients with long stenosis than with short stenosis at baseline (interaction P = 0.003). Results remained significant after multivariate adjustment. No associations were found for degree of stenosis and plaque surface. CONCLUSIONS: Increasing stenosis length is an independent risk factor for peri-procedural stroke or death in endovascular treatment and carotid endarterectomy, without favoring one treatment over the other. However, the excess restenosis rate after endovascular treatment compared with carotid endarterectomy increases with longer stenosis at baseline. Stenosis length merits further investigation in carotid revascularisation trials
- …
