138 research outputs found
Development of a Sandwich ELISA to Measure Exposure to Occupational Cow Hair Allergens
Background: Cow hair and dander are important inducers of occupational allergies in cattle-exposed farmers. To estimate allergen exposure in farming environments, a sensitive enzyme immunoassay was developed to measure cow hair allergens. Methods: A sandwich ELISA was developed using polyclonal rabbit antibodies against a mixture of hair extracts from different cattle breeds. To assess the specificity of the assay, extracts from other mammalian epithelia, mites, molds and grains were tested. To validate the new assay, cow hair allergens were measured in passive airborne dust samples from the stables and homes of farmers. Dust was collected with electrostatic dust fall collectors (EDCs). Results: The sandwich ELISA was found to be very sensitive (detection limit: 0.1 ng/ml) and highly reproducible, demonstrating intra-and interassay coefficients of variation of 4 and 10%, respectively. The assay showed no reactivity with mites, molds and grains, but some cross-reactivity with other mammalian epithelia, with the strongest reaction with goat. Using EDCs for dust sampling, high concentrations of bovine allergens were measured in cow stables (4,760-559,400 mu g/m(2)). In addition, bovine allergens were detected in all areas of cattle farmer dwellings. A large variation was found between individual samples (0.3-900 mu g/m(2)) and significantly higher values were discovered in changing rooms. Conclusion: The ELISA developed for the detection of cow hair proteins is a useful tool for allergen quantification in occupational and home environments. Based on its low detection limit, this test is sensitive enough to detect allergens in passive airborne dust. Copyright (C) 2011 S. Karger AG, Base
Quantitative Analysis of Immunoglobulin E Reactivity Profiles in Patients Allergic or Sensitized to Natural Rubber Latex (Hevea Brasiliensis)
Characterized native and recombinant Hevea brasiliensis (rHev b) natural rubber latex (NRL) allergens are available to assess patient allergen sensitization profiles.
OBJECTIVE:
Quantification of individual IgE responses to the spectrum of documented NRL allergens and evaluation of cross-reactive carbohydrate determinants (CCDs) for more definitive diagnosis.
METHODS:
Sera of 104 healthcare workers (HCW; 51 German, 21 Portuguese, 32 American), 31 spina bifida patients (SB; 11 German, 20 Portuguese) and 10 Portuguese with multiple surgeries (MS) were analysed for allergen-specific IgE antibody (sIgE) to NRL, single Hev b allergens and CCDs with ImmunoCAP technology.
RESULTS:
In all patient groups rHev b 5-sIgE concentrations were the most pronounced. Hev b 2, 5, 6.01 and 13 were identified as the major allergens in HCW and combined with Hev b 1 and Hev b 3 in SB. In MS Hev b 1 displayed an intermediate relevance. Different sIgE antibody levels to native Hevea brasiliensis (nHev b) 2 and rHev b 6.01 allowed discrimination of SB with clinical relevant latex allergy vs. those with latex sensitization. Sensitization profiles of German, Portuguese and American patients were equivalent. rHev b 5, 6.01 and nHev b 13 combined detected 100% of the latex-allergic HCW and 80.1% of the SB. Only 8.3% of the sera showed sIgE response to CCDs.
CONCLUSIONS:
Hev b 1, 2, 5, 6.01 and 13 were identified as the major Hev b allergens and they should be present in standardized latex extracts and in vitro allergosorbents. CCDs are only of minor relevance in patients with clinical relevant latex allergy. Component-resolved diagnostic analyses for latex allergy set the stage for an allergen-directed immunotherapy strateg
The uncertainties on the EFT coupling limits for direct dark matter detection experiments stemming from uncertainties of target properties
Direct detection experiments are still one of the most promising ways to
unravel the nature of dark matter. To fully understand how well these
experiments constrain the dark matter interactions with the Standard Model
particles, all the uncertainties affecting the calculations must be known. It
is especially critical now because direct detection experiments recently moved
from placing limits only on the two elementary spin independent and spin
dependent operators to the complete set of possible operators coupling dark
matter and nuclei in non-relativistic theory. In our work, we estimate the
effect of nuclear configuration-interaction uncertainties on the exclusion
bounds for one of the existing xenon-based experiments for all fifteen
operators. We find that for operator number 13 the uncertainty on
the coupling between the dark matter and nucleon can reach more than 50% for
dark matter masses between 10 and 1000 GeV. In addition, we discuss how quantum
computers can help to reduce this uncertainty.Comment: 12 pages, 6 figures; submitted to Phys. Rev. D, May 17, 202
Orbital Josephson effect and interactions in driven atom condensates on a ring
In a system of ac-driven condensed bosons we study a new type of Josephson
effect occurring between states sharing the same region of space and the same
internal atom structure. We first develop a technique to calculate the long
time dynamics of a driven interacting many-body system. For resonant
frequencies, this dynamics can be shown to derive from an effective
time-independent Hamiltonian which is expressed in terms of standard creation
and annihilation operators. Within the subspace of resonant states, and if the
undriven states are plane waves, a locally repulsive interaction between bosons
translates into an effective attraction. We apply the method to study the
effect of interactions on the coherent ratchet current of an asymmetrically
driven boson system. We find a wealth of dynamical regimes which includes Rabi
oscillations, self-trapping, and chaotic behavior. In the latter case, a full
many-body calculation deviates from the mean-field results by predicting large
quantum fluctuations of the relative particle number.Comment: Published versio
Parenting Science Gang : radical co-creation of research projects led by parents of young children
Background Parents are increasingly searching online for information supported by research but can find it difficult to identify results relevant to their own experiences. More troublingly, a number of studies indicate that parenting information found online often can be misleading or wrong. The goal of the Parenting Science Gang (PSG) project was to use the power of the Internet to help parents ask questions they wanted to have answered by scientific research and to feel confident in assessing research evidence. Methods By using Facebook to recruit groups and facilitate interactions, PSG was able to engage fully the target public of parents of young children in the radical co-production of scientific studies, while not creating an undue burden on time or restricting participants due to disability, financial status or location. By giving parents true partnership and control of creation of projects, PSG ensured that the chosen questions were ones that were of most relevance and interest to them. Results This paper presents a summary of eight projects, with three in more detail, designed and implemented by PSG Facebook groups in collaboration with experts. Most projects had health related themes, often prompted by dissatisfaction with treatment of parents by health professionals or by feelings of being marginalised by pregnancy and motherhood, as well as by the lack of evidence for their questions and concerns. The PSG approach meant that these frustrations were channelled into actions. All eight of the PSG groups engaged in meaningful interactions with experts and co-produced studies with the groups defining the questions of interest. Conclusions This radically user-led design meant that the PSG staff and the collaborating experts had to live with a high degree of uncertainty. Nevertheless, PSG achieved its goal of academically productive, truly co-produced projects, but as important were the positive effects it had on many of the participants, both parents and experts. At the point of writing this paper, PSG projects have led to outputs including at least eight papers published, in press or in preparation, seven conference presentations, testimony to the Infant Feeding All-Party Parliamentary Group, and with more to come
Development of an enzyme-linked immunosorbent assay for the detection of human calretinin in plasma and serum of mesothelioma patients
<p>Abstract</p> <p>Background</p> <p>Calretinin is one of the well-established immunohistochemical markers in the diagnostics of malignant mesothelioma (MM). Its utility as a diagnostic tool in human blood, however, is scarcely investigated. The aim of this study was to develop an enzyme-linked immunosorbent assay (ELISA) for human calretinin in blood and to assess its usefulness as a potential minimally invasive diagnostic marker for MM.</p> <p>Methods</p> <p>Initially, attempts were made to establish an assay using commercially available antibodies and to optimize it by including a biotin-streptavidin complex into the assay protocol. Subsequently, a novel ELISA based on polyclonal antibodies raised in rabbit immunized with human recombinant calretinin was developed. The assay performance in human serum and plasma (EDTA/heparin) and the influence of calcium concentrations on antibody recognition were studied. Stability of spiked-in calretinin in EDTA plasma under different storage conditions was also examined. In preliminary studies serum and plasma samples from 97 healthy volunteers, 35 asbestos-exposed workers, and 42 MM patients were analyzed.</p> <p>Results</p> <p>The mean detection range of the new ELISA was 0.12 to 8.97 ng/ml calretinin. The assay demonstrated markedly lower background and significantly higher sensitivity compared to the initially contrived assay that used commercial antibodies. Recovery rate experiments confirmed dependence of calretinin antibody recognition on calcium concentration. Calcium adjustment is necessary for calretinin measurement in EDTA plasma. Spiked-in calretinin revealed high stability in EDTA plasma when stored at room temperature, 4°C, or after repeated freeze/thaw cycles. Median calretinin values in healthy volunteers, asbestos workers, and MM patients were 0.20, 0.33, and 0.84 ng/ml, respectively (p < 0.0001 for healthy vs. MM, p = 0.0036 for healthy vs. asbestos-exposed, p < 0.0001 for asbestos-exposed vs. MM). Median values in patients with epithelioid and biphasic MM were similar. No influence of age, gender, smoking status, or type of medium (plasma/serum) on calretinin values was found.</p> <p>Conclusions</p> <p>The novel assay is highly sensitive and applicable to human serum and plasma. Calretinin appears to be a promising marker for the blood-based detection of MM and might complement other markers. However, further studies are required to prove its usefulness in the diagnosis of MM patients.</p
Comparative analysis of selected exhaled breath biomarkers obtained with two different temperature-controlled devices
<p>Abstract</p> <p>Background</p> <p>The collection of exhaled breath condensate (EBC) is a suitable and non-invasive method for evaluation of airway inflammation. Several studies indicate that the composition of the condensate and the recovery of biomarkers are affected by physical characteristics of the condensing device and collecting circumstances. Additionally, there is an apparent influence of the condensing temperature, and often the level of detection of the assay is a limiting factor. The ECoScreen2 device is a new, partly single-use disposable system designed for studying different lung compartments.</p> <p>Methods</p> <p>EBC samples were collected from 16 healthy non-smokers by using the two commercially available devices ECoScreen2 and ECoScreen at a controlled temperature of -20°C. EBC volume, pH, NOx, LTB<sub>4</sub>, PGE<sub>2</sub>, 8-isoprostane and cys-LTs were determined.</p> <p>Results</p> <p>EBC collected with ECoScreen2 was less acidic compared to ECoScreen. ECoScreen2 was superior concerning condensate volume and detection of biomarkers, as more samples were above the detection limit (LTB<sub>4 </sub>and PGE<sub>2</sub>) or showed higher concentrations (8-isoprostane). However, NOx was detected only in EBC sampled by ECoScreen.</p> <p>Conclusion</p> <p>ECoScreen2 in combination with mediator specific enzyme immunoassays may be suitable for measurement of different biomarkers. Using this equipment, patterns of markers can be assessed that are likely to reflect the complex pathophysiological processes in inflammatory respiratory disease.</p
EAACI position paper on occupational rhinitis
The present document is the result of a consensus reached by a panel of experts from European and non-European countries on Occupational Rhinitis (OR), a disease of emerging relevance which has received little attention in comparison to occupational asthma. The document covers the main items of OR including epidemiology, diagnosis, management, socio-economic impact, preventive strategies and medicolegal issues. An operational definition and classification of OR tailored on that of occupational asthma, as well as a diagnostic algorithm based on steps allowing for different levels of diagnostic evidence are proposed. The needs for future research are pointed out. Key messages are issued for each item
- …
