507 research outputs found
Angioplasty in acute middle cerebral artery stroke due to atrial fibrillation selected by CT perfusion: a case report
We report the experience of a case of acute stroke in a patient affected by Rendu Osler syndrome and atrial fibrillation. The combination of dynamic computerized tomography perfusion scans and the use of a high-compliance balloon allowed increasing the treatment window for intra-arterial recanalization over 6 h after stroke onset in a patient with middle cerebral artery occlusion
Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector
Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente
Percutaneous vascular interventions for acute ischaemic stroke.
peer-reviewedMost disabling strokes are due to blockage of a large artery in the brain by a blood clot. Prompt removal of the clot with intra-arterial thrombolytic drugs or mechanical devices, or both, can restore blood flow before major brain damage has occurred, leading to improved recovery. However, these so-called percutaneous vascular interventions can cause bleeding in the brain.PUBLISHEDpeer-reviewe
Measurement of the t¯tZ and t¯tW cross sections in proton-proton collisions at √s=13 TeV with the ATLAS detector
A measurement of the associated production of a top-quark pair (t¯t) with a vector boson (W, Z) in proton-proton collisions at a center-of-mass energy of 13 TeV is presented, using 36.1 fb−1 of integrated luminosity collected by the ATLAS detector at the Large Hadron Collider. Events are selected in channels with two same- or opposite-sign leptons (electrons or muons), three leptons or four leptons, and each channel is further divided into multiple regions to maximize the sensitivity of the measurement. The t¯tZ and t¯tW production cross sections are simultaneously measured using a combined fit to all regions. The best-fit values of the production cross sections are σt¯tZ=0.95±0.08stat±0.10syst pb and σt¯tW=0.87±0.13stat±0.14syst pb in agreement with the Standard Model predictions. The measurement of the t¯tZ cross section is used to set constraints on effective field theory operators which modify the t¯tZ vertex
Ten-year follow-up of giant basilar aneurysm treated by sole stenting technique: a case report
<p>Abstract</p> <p>Introduction</p> <p>The sole stenting technique has emerged as a new tool for the management of intracranial aneurysms. However, several concerns have emerged about the long-term behavior of intracranial stents, particularly their safety and efficacy.</p> <p>Case presentation</p> <p>We present the first case of an intracranial aneurysm intentionally treated with the sole stenting technique. After ten years of clinical and imaging follow-up, the lesion has healed and no intrastent stenosis is observed.</p> <p>Several issues concerning this technique are discussed. For instance, the modification of the angle and intra-aneurysmal thrombosis may account as positive effects; negative outcomes include in-stent thrombosis or stenosis.</p> <p>Conclusions</p> <p>This case report, involving a long clinical and imaging follow-up, provides an example of the effectiveness, safety, durability and simplicity of the sole stenting technique in the management of intracranial aneurysms.</p
Pseudoaneurysm of the internal carotid artery presenting with massive (recurrent) epistaxes: a life-threatening complication of craniofacial trauma
Predictors of functional outcome vary by the hemisphere of involvement in major ischemic stroke treated with intra-arterial therapy: a retrospective cohort study
<p>Abstract</p> <p>Background</p> <p>Conflicting data exists regarding the effect of hemispheric lateralization on acute ischemic stroke outcome. Some of this variability may be related to heterogeneous study populations, particularly with respect to the level of arterial occlusion. Furthermore, little is known about the relationship between stroke lateralization and predictors of outcome. The purpose of this study was to characterize the impact of stroke lateralization on both functional outcome and its predictors in a well-defined population of anterior circulation proximal artery occlusions treated with IAT.</p> <p>Methods</p> <p>Thirty-five consecutive left- and 35 consecutive right-sided stroke patients with intracranial ICA and/or MCA occlusions who underwent IAT were retrospectively analyzed. Ischemic change on pre-treatment imaging was quantified. Reperfusion success was graded using the Mori scale. Good outcome at three months was defined as an mRS ≤ 2. Left- and right-sided strokes were compared for outcome and its predictors.</p> <p>Result</p> <p>Of 70 patients with median NIHSS score of 18 (IQR, 14-21), 19 (27.1%) had a good outcome. There were 21 terminal ICA and 49 MCA occlusions. There was no difference in the rate of good outcomes between left- (n = 9) and right-sided (n = 10) strokes (p = 0.99). There were no significant differences in occlusion level, age, ischemic change on initial imaging and degree of reperfusion between left- and right-sided strokes. Left-sided strokes had higher baseline NIHSS scores (p = 0.02) and lower admission SBP (p = 0.009). Independent predictors of outcome for left-sided strokes were NIHSS (p = 0.0002) and reperfusion (p = 0.006), and for right-sided strokes were age (p = 0.002) and reperfusion (p = 0.003). In univariate analysis, pre-treatment ischemic change on NCCT was associated with outcome only for left-sided strokes (p = 0.05).</p> <p>Conclusions</p> <p>In anterior circulation proximal artery occlusions treated with IAT, hemispheric lateralization influences the clinical and imaging predictors of outcome. Most notably, NIHSS predicts outcome only for the left-sided strokes in this population. This finding has important implications for outcome prediction in the acute setting and indicates a need for stroke severity scales more sensitive to right hemispheric deficits.</p
Fabrication and in vitro deployment of a laser-activated shape memory polymer vascular stent
<p>Abstract</p> <p>Background</p> <p>Vascular stents are small tubular scaffolds used in the treatment of arterial stenosis (narrowing of the vessel). Most vascular stents are metallic and are deployed either by balloon expansion or by self-expansion. A shape memory polymer (SMP) stent may enhance flexibility, compliance, and drug elution compared to its current metallic counterparts. The purpose of this study was to describe the fabrication of a laser-activated SMP stent and demonstrate photothermal expansion of the stent in an <it>in vitro </it>artery model.</p> <p>Methods</p> <p>A novel SMP stent was fabricated from thermoplastic polyurethane. A solid SMP tube formed by dip coating a stainless steel pin was laser-etched to create the mesh pattern of the finished stent. The stent was crimped over a fiber-optic cylindrical light diffuser coupled to an infrared diode laser. Photothermal actuation of the stent was performed in a water-filled mock artery.</p> <p>Results</p> <p>At a physiological flow rate, the stent did not fully expand at the maximum laser power (8.6 W) due to convective cooling. However, under zero flow, simulating the technique of endovascular flow occlusion, complete laser actuation was achieved in the mock artery at a laser power of ~8 W.</p> <p>Conclusion</p> <p>We have shown the design and fabrication of an SMP stent and a means of light delivery for photothermal actuation. Though further studies are required to optimize the device and assess thermal tissue damage, photothermal actuation of the SMP stent was demonstrated.</p
Thrombus imaging in acute stroke: correlation of thrombus length on susceptibility-weighted imaging with endovascular reperfusion success
OBJECTIVES
Susceptibility-weighted imaging (SWI) enables visualization of thrombotic material in acute ischemic stroke. We aimed to validate the accuracy of thrombus depiction on SWI compared to time-of-flight MRA (TOF-MRA), first-pass gadolinium-enhanced MRA (GE-MRA) and digital subtraction angiography (DSA). Furthermore, we analysed the impact of thrombus length on reperfusion success with endovascular therapy.
METHODS
Consecutive patients with acute ischemic stroke due to middle cerebral artery (MCA) occlusions undergoing endovascular recanalization were screened. Only patients with a pretreatment SWI were included. Thrombus visibility and location on SWI were compared to those on TOF-MRA, GE-MRA and DSA. The association between thrombus length on SWI and reperfusion success was studied.
RESULTS
Eighty-four of the 88 patients included (95.5 %) showed an MCA thrombus on SWI. Strong correlations between thrombus location on SWI and that on TOF-MRA (Pearson's correlation coefficient 0.918, P < 0.001), GE-MRA (0.887, P < 0.001) and DSA (0.841, P < 0.001) were observed. Successful reperfusion was not significantly related to thrombus length on SWI (P = 0.153; binary logistic regression).
CONCLUSIONS
In MCA occlusion thrombus location as seen on SWI correlates well with angiographic findings. In contrast to intravenous thrombolysis, thrombus length appears to have no impact on reperfusion success of endovascular therapy.
KEY POINTS
• SWI helps in assessing location and length of thrombi in the MCA • SWI, MRA and DSA are equivalent in detecting the MCA occlusion site • SWI is superior in identifying the distal end of the thrombus • Stent retrievers should be deployed over the distal thrombus end • Thrombus length did not affect success of endovascular reperfusion guided by SWI
- …
