244 research outputs found
Response to ‘Pulmonary arterial hypertension: An update’ by M. Correale (10.1007/s12471-012-0245-2)
Right Heart Dysfunction in Heart Failure with Preserved Ejection Fraction:the Impact of Atrial Fibrillation
BACKGROUND: Right ventricular (RV) dysfunction and atrial fibrillation (AF) frequently coexist in heart failure with preserved ejection fraction (HFpEF). The mechanisms underlying the association between AF and RV dysfunction are incompletely understood. METHODS AND RESULTS: 102 patients were identified. RV function was assessed using multiple echocardiographic parameters and dysfunction was present if ≥2 parameters were below the recommended cutoff. RV function, right atrial (RA) reservoir strain and RA emptying fraction, were compared between AF and sinus rhythm. 91 patients with sufficient echocardiographic quality were included: 45 (50%) had no history of AF; 14 (15%) had prior AF while in sinus rhythm; 32 (35%) had current AF. The prevalence of RV dysfunction varied across subgroups never AF, prior AF and current AF (20%, 43% and 63%, respectively, p=0.001). AF was associated with RV dysfunction (OR 4.70 [1.82-12.1], p=0.001) - independent of pulmonary pressures. In patients in sinus rhythm with prior AF, RA emptying fraction was lower compared to patients without AF history (41 vs. 60%, p=0.002). Prior AF was also associated with reduced RA reservoir strain (OR 4.57 [1.05-19.9], p=0.04) - independent of RV end-diastolic pressure. CONCLUSIONS: Atrial fibrillation is strongly related to reduced RV and RA function in HFpEF, independent of pulmonary pressures
Fertility, pregnancy and delivery in women after biventricular repair for double outlet right ventricle
Objectives: To investigate outcome of pregnancy and fertility in women with double outlet right ventricle (DORV). Methods: Using 2 congenital heart disease registries, 21 female patients with DORV (aged 18-39 years) were retrospectively identified. Detailed recordings of each patient and their completed (>20 weeks gestation) pregnancies were recorded. Results: Overall, 10 patients had 19 pregnancies, including 3 spontaneous miscarriages (16%). During the 16 live birth pregnancies, primarily (serious) noncardiac complications were observed, e.g. premature labor/delivery (n = 7 and n = 3, respectively), small for gestational age (n = 4), preeclampsia (n = 2) and recurrence of congenital heart disease (n = 2). Except for postpartum endocarditis and deterioration of subpulmonary obstruction, only mild cardiac complication pregnancies were recorded. Two women with children reported secondary female infertility. Several menstrual cycle disorders were reported: secondary amenorrhea (n = 4), primary amenorrhea (n = 3) and oligomenorrhea (n = 2). Conclusion: Successful pregnancy in women with DORV is possible. Primarily noncardiac complications were observed and only few (minor) cardiac complications. Infertility and menstrual cycle disorders appear to be more prevalent. Copyrigh
Platypnea orthodeoxia syndrome after recent stroke:A case report of a sandwiched right atrium
Background: Platypnea orthodeoxia syndrome (POS) is a condition characterized by onset or worsening of dyspnoea and desaturation in upright position that is relieved by returning to a supine position. This case report illustrates a sudden onset of severe platypnea caused by compression of the right atrium (RA) due to aortic dilatation and unilateral diaphragmatic paralysis after a recent stroke. Case summary: A 71-year-male patient with a medical history of recent stroke of the left hemisphere was referred to emergency department with acute dyspnoea. During observation in the emergency department, desaturation was noted in upright position. A contrast computed tomography excluded pulmonary embolism but revealed a dilated aortic root and an elevated right hemidiaphragm. The RA was compressed between these two structures (sandwiched). Given the clinical suspicion of a POS, a transoesophageal echocardiography was performed which confirmed the presence of a persistent foramen ovale (PFO) in supine position. In upright position, there was a torrential increase in right-to-left shunting. The PFO was closed using an Occlutech™ device. Directly after the procedure, the patient was symptom free. Discussion: A rise in RA pressure or difference in flow pattern in the RA can make a PFO become symptomatic. Elevated RA pressure was ruled out. Most anatomical pathologies influencing the flow pattern develop slowly over time. This case shows a presentation of POS after a recent stroke possible due to change in anatomy because of right hemidiaphragm paralysis in combination with the aortic dilatation
Percutaneous tricuspid valve repair using MitraClip (R) for the treatment of severe tricuspid valve regurgitation in a patient with congenitally corrected transposition of the great arteries
Abnormal Venous Flow in Pregnant Women with Mild Right Ventricular Dysfunction in Repaired Tetralogy of Fallot:A Clinical Model for Organ Dysfunction in Preeclampsia
Background: Pregnant women with congenital heart disease carry a high risk of complications, especially when cardiac function is suboptimal. Increasing evidence suggests that impaired right ventricular (RV) function has a negative effect on placental function, possibly through venous congestion. We report a case series of hepatic and renal venous flow patterns in pregnant women with right ventricular dysfunction after repaired Tetralogy of Fallot (ToF), relative to those observed in normal pregnancy and preeclampsia. Methods: At 20–24 weeks pregnancy, RV function was measured by echocardiography and by cardiovascular magnetic resonance in women with repaired ToF. Combined Doppler-ECG of the hepatic and renal interlobular veins were performed in three women with asymptomatic right ventricular dysfunction. Venous impedance index and pulse transit time were measured and classified as abnormal at >75th and <25th reference percentile, respectively. Results: All three women showed dilated RV and mildly impaired RV function. Both hepatic and intrarenal Doppler flow waves were abnormal and very much resembled the patterns seen in preeclampsia. One of the three women had complications including ventricular tachycardia, intrauterine growth restriction, antenatal bleeding, emergency cesarean section and acute heart failure 2 days postpartum. Conclusions: Pregnant women with mild right ventricular dysfunction after repaired ToF show abnormal venous Doppler flow waves in the liver and kidneys, similar to those observed in preeclampsia. These findings are in line with reported observations on the association between impaired RV function, abnormal return of venous blood, venous congestion and organ dysfunction. The parallel with venous Doppler flow observations in preeclampsia suggest that the venous compartment might play an important role in the etiology of preeclampsia-induced organ dysfunction. Whether this phenomenon directly affects the uteroplacental circulation is to be assessed in future research.</p
Epicardial Adipose Tissue and Invasive Hemodynamics in Heart Failure With Preserved Ejection Fraction
Objectives: This study examined associations between epicardial adipose tissue (EAT), invasive hemodynamics, and exercise capacity in patients with heart failure with preserved ejection fraction (HFpEF). Background: EAT is increased in patients with HFpEF and may play a role in the pathophysiology of this disorder. Methods: Patients with heart failure and a left ventricular ejection fraction >45% who underwent right and left heart catheterization with simultaneous echocardiography were included. Pulmonary capillary wedge pressure (PCWP), left ventricular end-diastolic pressure (LVEDP), right ventricular end-diastolic pressure (RVEDP), and pulmonary vascular resistance (PVR) were invasively measured. Obesity was defined as body mass index (BMI) ≥30 kg/m2. EAT thickness alongside the right ventricle was measured on echocardiographic long- and short-axis views. Cardiopulmonary exercise testing was performed to obtain maximal oxygen uptake (VO2-max). Results: This study examined 75 patients, mean age 74 ± 9 years; 68% were women, mean BMI was 29 ± 6 kg/m2, and 36% were obese. Higher BMI was strongly associated with increased EAT (r = 0.74; p < 0.001). Increased EAT was associated with higher RVEDP, independent of PVR (odds ratio [OR]: 1.16; 95% confidence interval [CI]: 1.02 to 1.34; p = 0.03), but not independent of obesity (p = 0.10). Increased EAT and higher RVEDP were both associated with lower VO2-max (r = −0.43; p < 0.001 and r = −0.43; p = 0.001, respectively). Increased EAT remained associated with lower VO2-max after adjustment for PVR (OR: 0.64; 95% CI: 0.49 to 0.84; p = 0.002) and obesity (OR: 0.69; 95% CI: 0.53 to 0.92; p = 0.01). EAT thickness was not associated with left-sided filling pressures (i.e., PCWP and LVEDP). Conclusions: In HFpEF, obesity and increased EAT were associated with higher right-sided filling pressures and with reduced exercise capacity
Cardiac output drop reflects circulatory attrition after Fontan completion:serial cardiac magnetic resonance study
AIMS: Cardiac magnetic resonance (CMR) imaging is a main diagnostic tool in the follow-up of Fontan patients. However, the value of serial CMR for the evaluation of Fontan attrition is unknown. The aim of this prospective study of serial CMR is to describe the analysis of time-dependent evolution of blood flow distribution, ventricular volumes, and function in patients after Fontan completion.METHODS AND RESULTS: In this prospective single-centre study, between 2012 and 2022, 281 CMR examinations were performed in 88 Fontan patients with distribution of blood flows, measurements of ventricular volumes, and ejection fraction. Linear mixed model regression for repeated measurements was used to analyse changes of measurements across serial CMR examinations. During a time interval of 10 years, the median number of CMR per patient was 3 (range 1-5). Indexed flow of ascending aorta, caval veins, and pulmonary arteries decreased significantly across serial CMR examinations. Although a decrease of mean indexed aortic flow (3.03 ± 0.10 L/min/m 2 at first CMR vs. 2.36 ± 0.14 L/min/m 2 at fourth CMR, P < 0.001) was observed, ejection fraction did not decline (50 ± 1% at first CMR vs. 54 ± 2% at fourth CMR, P = 0.070). Indexed ventricular volumes did not differ significantly across serial CMR examinations. CONCLUSION: The decrease of indexed aortic and cavopulmonary flows reflects the attrition of univentricular circulation and can be detected by means of serial CMR. Ventricular systolic dysfunction does not contribute significantly to this attrition. In order to detect significant change of indexed aortic flow, we recommend performing serial CMR as routine practice in the Fontan population.</p
- …
