3,877 research outputs found

    Temporal Upsampling of Depth Maps Using a Hybrid Camera

    Full text link
    In recent years, consumer-level depth cameras have been adopted for various applications. However, they often produce depth maps at only a moderately high frame rate (approximately 30 frames per second), preventing them from being used for applications such as digitizing human performance involving fast motion. On the other hand, low-cost, high-frame-rate video cameras are available. This motivates us to develop a hybrid camera that consists of a high-frame-rate video camera and a low-frame-rate depth camera and to allow temporal interpolation of depth maps with the help of auxiliary color images. To achieve this, we develop a novel algorithm that reconstructs intermediate depth maps and estimates scene flow simultaneously. We test our algorithm on various examples involving fast, non-rigid motions of single or multiple objects. Our experiments show that our scene flow estimation method is more precise than a tracking-based method and the state-of-the-art techniques.Comment: IEEE Transactions on Visualization and Computer Graphics, 2018(13 pages, 16 figures

    Development of a Vacuum Ultra-Violet Laser-Based Angle-Resolved Photoemission System with a Super-High Energy Resolution Better Than 1 meV

    Full text link
    The design and performance of the first vacuum ultra-violet (VUV) laser-based angle-resolved photoemission (ARPES) system are described. The VUV laser with a photon energy of 6.994 eV and bandwidth of 0.26 meV is achieved from the second harmonic generation using a novel non-linear optical crystal KBe2BO3F2 (KBBF). The new VUV laser-based ARPES system exhibits superior performance, including super-high energy resolution better than 1 meV, high momentum resolution, super-high photon flux and much enhanced bulk sensitivity, which are demonstrated from measurements on a typical Bi2Sr2CaCu2O8 high temperature superconductor. Issues and further development related to the VUV laser-based photoemission technique are discussed.Comment: 29 pages, 10 figures, submitted to Review of Scientific Instrument

    Light trapping in ultrathin plasmonic solar cells

    Get PDF
    We report on the design, fabrication, and measurement of ultrathin film a-Si:H solar cells with nanostructured plasmonic back contacts, which demonstrate enhanced short circuit current densities compared to cells having flat or randomly textured back contacts. The primary photocurrent enhancement occurs in the spectral range from 550 nm to 800 nm. We use angle-resolved photocurrent spectroscopy to confirm that the enhanced absorption is due to coupling to guided modes supported by the cell. Full-field electromagnetic simulation of the absorption in the active a-Si:H layer agrees well with the experimental results. Furthermore, the nanopatterns were fabricated via an inexpensive, scalable, and precise nanopatterning method. These results should guide design of optimized, non-random nanostructured back reflectors for thin film solar cells

    Nanomechanical Contribution of Collagen and von Willebrand Factor A in Marine Underwater Adhesion and Its Implication for Collagen Manipulation

    Get PDF
    Recent works on mussel adhesion have identified a load bearing matrix protein (PTMP1) containing von Willebrand factor (vWF) with collagen binding capability that contributes to the mussel holdfast by manipulating mussel collagens. Using a surface forces apparatus, we investigate for the first time, the nanomechanical properties of vWF-collagen interaction using homologous proteins of mussel byssus, PTMP1 and preCollagens (preCols), as collagen. Mimicking conditions similar to mussel byssus secretion (pH < 5.0) and seawater condition (pH 8.0), PTMP1 and preCol interact weakly in the "positioning" phase based on vWF-collagen binding and strengthen in "locked" phase due to the combined effects of electrostatic attraction, metal binding, and mechanical shearing. The progressive enhancement of binding between PTMP1 with porcine collagen under the aforementioned conditions is also observed. The binding mechanisms of PTMP1-preCols provide insights into the molecular interaction of the mammalian collagen system and the development of an artificial extracellular matrix based on collagens.1142sciescopu

    Simultaneous noninvasive recording of skin sympathetic nerve activity and electrocardiogram

    Get PDF
    BACKGROUND: Sympathetic nerve activity is important to cardiac arrhythmogenesis. OBJECTIVE: The purpose of this study was to develop a method for simultaneous noninvasive recording of skin sympathetic nerve activity (SKNA) and electrocardiogram (ECG) using conventional ECG electrodes. This method (neuECG) can be used to adequately estimate sympathetic tone. METHODS: We recorded neuECG signals from the skin of 56 human subjects. The signals were low-pass filtered to show the ECG and high-pass filtered to show nerve activity. Protocol 1 included 12 healthy volunteers who underwent cold water pressor test and Valsalva maneuver. Protocol 2 included 19 inpatients with epilepsy but without known heart diseases monitored for 24 hours. Protocol 3 included 22 patients admitted with electrical storm and monitored for 39.0 ± 28.2 hours. Protocol 4 included 3 patients who underwent bilateral stellate ganglion blockade with lidocaine injection. RESULTS: In patients without heart diseases, spontaneous nerve discharges were frequently observed at baseline and were associated with heart rate acceleration. SKNA recorded from chest leads (V1-V6) during cold water pressor test and Valsalva maneuver (protocol 1) was invariably higher than during baseline and recovery periods (P < .001). In protocol 2, the average SKNA correlated with heart rate acceleration (r = 0.73 ± 0.14, P < .05) and shortening of QT interval (P < .001). Among 146 spontaneous ventricular tachycardia episodes recorded in 9 patients of protocol 3, 106 episodes (73%) were preceded by SKNA within 30 seconds of onset. Protocol 4 showed that bilateral stellate ganglia blockade by lidocaine inhibited SKNA. CONCLUSION: SKNA is detectable using conventional ECG electrodes in humans and may be useful in estimating sympathetic tone

    Intermittent left cervical vagal nerve stimulation damages the stellate ganglia and reduces the ventricular rate during sustained atrial fibrillation in ambulatory dogs

    Get PDF
    BACKGROUND: The effects of intermittent open-loop vagal nerve stimulation (VNS) on the ventricular rate (VR) during atrial fibrillation (AF) remain unclear. OBJECTIVE: The purpose of this study was to test the hypothesis that VNS damages the stellate ganglion (SG) and improves VR control during persistent AF. METHODS: We performed left cervical VNS in ambulatory dogs while recording the left SG nerve activity (SGNA) and vagal nerve activity. Tyrosine hydroxylase (TH) staining and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining were used to assess neuronal cell death in the SG. RESULTS: We induced persistent AF by atrial pacing in 6 dogs, followed by intermittent VNS with short ON-time (14 seconds) and long OFF-time (66 seconds). The integrated SGNA and VR during AF were 4.84 mV·s (95% confidence interval [CI] 3.08-6.60 mV·s) and 142 beats/min (95% CI 116-168 beats/min), respectively. During AF, VNS reduced the integrated SGNA and VR, respectively, to 3.74 mV·s (95% CI 2.27-5.20 mV·s; P = .021) and 115 beats/min (95% CI 96-134 beats/min; P = .016) during 66-second OFF-time and to 4.07 mV·s (95% CI 2.42-5.72 mV·s; P = .037) and 114 beats/min (95% CI 83-146 beats/min; P = .039) during 3-minute OFF-time. VNS increased the frequencies of prolonged (>3 seconds) pauses during AF. TH staining showed large confluent areas of damage in the left SG, characterized by pyknotic nuclei, reduced TH staining, increased percentage of TH-negative ganglion cells, and positive TUNEL staining. Occasional TUNEL-positive ganglion cells were also observed in the right SG. CONCLUSION: VNS damaged the SG, leading to reduced SGNA and better rate control during persistent AF

    Cost-effectiveness of non-invasive methods for assessment and monitoring of liver fibrosis and cirrhosis in patients with chronic liver disease: systematic review and economic evaluation

    Get PDF
    BACKGROUND: Liver biopsy is the reference standard for diagnosing the extent of fibrosis in chronic liver disease; however, it is invasive, with the potential for serious complications. Alternatives to biopsy include non-invasive liver tests (NILTs); however, the cost-effectiveness of these needs to be established. OBJECTIVE: To assess the diagnostic accuracy and cost-effectiveness of NILTs in patients with chronic liver disease. DATA SOURCES: We searched various databases from 1998 to April 2012, recent conference proceedings and reference lists. METHODS: We included studies that assessed the diagnostic accuracy of NILTs using liver biopsy as the reference standard. Diagnostic studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Meta-analysis was conducted using the bivariate random-effects model with correlation between sensitivity and specificity (whenever possible). Decision models were used to evaluate the cost-effectiveness of the NILTs. Expected costs were estimated using a NHS perspective and health outcomes were measured as quality-adjusted life-years (QALYs). Markov models were developed to estimate long-term costs and QALYs following testing, and antiviral treatment where indicated, for chronic hepatitis B (HBV) and chronic hepatitis C (HCV). NILTs were compared with each other, sequential testing strategies, biopsy and strategies including no testing. For alcoholic liver disease (ALD), we assessed the cost-effectiveness of NILTs in the context of potentially increasing abstinence from alcohol. Owing to a lack of data and treatments specifically for fibrosis in patients with non-alcoholic fatty liver disease (NAFLD), the analysis was limited to an incremental cost per correct diagnosis. An analysis of NILTs to identify patients with cirrhosis for increased monitoring was also conducted. RESULTS: Given a cost-effectiveness threshold of £20,000 per QALY, treating everyone with HCV without prior testing was cost-effective with an incremental cost-effectiveness ratio (ICER) of £9204. This was robust in most sensitivity analyses but sensitive to the extent of treatment benefit for patients with mild fibrosis. For HBV [hepatitis B e antigen (HBeAg)-negative)] this strategy had an ICER of £28,137, which was cost-effective only if the upper bound of the standard UK cost-effectiveness threshold range (£30,000) is acceptable. For HBeAg-positive disease, two NILTs applied sequentially (hyaluronic acid and magnetic resonance elastography) were cost-effective at a £20,000 threshold (ICER: £19,612); however, the results were highly uncertain, with several test strategies having similar expected outcomes and costs. For patients with ALD, liver biopsy was the cost-effective strategy, with an ICER of £822. LIMITATIONS: A substantial number of tests had only one study from which diagnostic accuracy was derived; therefore, there is a high risk of bias. Most NILTs did not have validated cut-offs for diagnosis of specific fibrosis stages. The findings of the ALD model were dependent on assuptions about abstinence rates assumptions and the modelling approach for NAFLD was hindered by the lack of evidence on clinically effective treatments. CONCLUSIONS: Treating everyone without NILTs is cost-effective for patients with HCV, but only for HBeAg-negative if the higher cost-effectiveness threshold is appropriate. For HBeAg-positive, two NILTs applied sequentially were cost-effective but highly uncertain. Further evidence for treatment effectiveness is required for ALD and NAFLD. STUDY REGISTRATION: This study is registered as PROSPERO CRD42011001561. FUNDING: The National Institute for Health Research Health Technology Assessment programme
    corecore