47 research outputs found

    Lung dendritic cells induce migration of protective T cells to the gastrointestinal tract

    Get PDF
    Developing efficacious vaccines against enteric diseases is a global challenge that requires a better understanding of cellular recruitment dynamics at the mucosal surfaces. The current paradigm of T cell homing to the gastrointestinal (GI) tract involves the induction of alpha 4 beta 7 and CCR9 by Peyer's patch and mesenteric lymph node (MLN) dendritic cells (DCs) in a retinoic acid-dependent manner. This paradigm, however, cannot be reconciled with reports of GI T cell responses after intranasal (i.n.) delivery of antigens that do not directly target the GI lymphoid tissue. To explore alternative pathways of cellular migration, we have investigated the ability of DCs from mucosal and nonmucosal tissues to recruit lymphocytes to the GI tract. Unexpectedly, we found that lung DCs, like CD103(+) MLN DCs, up-regulate the gut-homing integrin alpha 4 beta 7 in vitro and in vivo, and induce T cell migration to the GI tract in vivo. Consistent with a role for this pathway in generating mucosal immune responses, lung DC targeting by i.n. immunization induced protective immunity against enteric challenge with a highly pathogenic strain of Salmonella. The present report demonstrates novel functional evidence of mucosal cross talk mediated by DCs, which has the potential to inform the design of novel vaccines against mucosal pathogens.open8

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Hepatic lipogranulomas in patients with chronic liver disease: Association with hepatitis C and fatty liver disease

    No full text
    AIM: To study the significance and clinical implication of hepatic lipogranuloma in chronic liver diseases, including fatty liver disease and hepatitis C

    Establishment and Application of a Novel Difficulty Scoring System for da Vinci Robotic Pancreatoduodenectomy

    No full text
    BackgroundRobotic pancreatoduodenectomy (RPD) technology is developing rapidly, but there is still a lack of a specific and objective difficulty evaluation system in the field of application and training of RPD surgery.MethodsThe clinical data of patients who underwent RPD in our hospital from November 2014 to October 2020 were analyzed retrospectively. Univariate and multivariate logistic regression analyses were used to determine the predictors of operation difficulty and convert into a scoring system.ResultsA total of 72 patients were enrolled in the group. According to the operation time (25%), intraoperative blood loss (25%), conversion to laparotomy, and major complications, the difficulty of operation was divided into low difficulty (0–2 points) and high difficulty (3–4 points). The multivariate logistic regression model included the thickness of mesenteric tissue (P1) (P = 0.035), the thickness of the abdominal wall (B1) (P = 0.017), and the preoperative albumin (P = 0.032), and the nomogram was established. AUC = 0.773 (0.645–0.901).ConclusionsThe RPD difficulty evaluation system based on the specific anatomical relationship between da Vinci’s laparoscopic robotic arm and tissues/organs in the operation area can be used as a predictive tool to evaluate the surgical difficulty of patients before operation and guide clinical practice.</jats:sec

    Morphologic Features of Extrahepatic Manifestations of Hepatitis C Virus Infection

    Get PDF
    Cirrhosis and hepatocellular carcinoma are the prototypic complications of chronic hepatitis C virus infection in the liver. However, hepatitis C virus also affects a variety of other organs that may lead to significant morbidity and mortality. Extrahepatic manifestations of hepatitis C infection include a multitude of disease processes affecting the small vessels, skin, kidneys, salivary gland, eyes, thyroid, and immunologic system. The majority of these conditions are thought to be immune mediated. The most documented of these entities is mixed cryoglobulinemia. Morphologically, immune complex depositions can be identified in small vessels and glomerular capillary walls, leading to leukoclastic vasculitis in the skin and membranoproliferative glomerulonephritis in the kidney. Other HCV-associated entities include porphyria cutanea tarda, lichen planus, necrolytic acral erythema, membranous glomerulonephritis, diabetic nephropathy, B-cell non-Hodgkin lymphomas, insulin resistance, sialadenitis, sicca syndrome, and autoimmune thyroiditis. This paper highlights the histomorphologic features of these processes, which are typically characterized by chronic inflammation, immune complex deposition, and immunoproliferative disease in the affected organ

    Table_2_v1_Establishment and Application of a Novel Difficulty Scoring System for da Vinci Robotic Pancreatoduodenectomy.docx

    No full text
    BackgroundRobotic pancreatoduodenectomy (RPD) technology is developing rapidly, but there is still a lack of a specific and objective difficulty evaluation system in the field of application and training of RPD surgery.MethodsThe clinical data of patients who underwent RPD in our hospital from November 2014 to October 2020 were analyzed retrospectively. Univariate and multivariate logistic regression analyses were used to determine the predictors of operation difficulty and convert into a scoring system.ResultsA total of 72 patients were enrolled in the group. According to the operation time (25%), intraoperative blood loss (25%), conversion to laparotomy, and major complications, the difficulty of operation was divided into low difficulty (0–2 points) and high difficulty (3–4 points). The multivariate logistic regression model included the thickness of mesenteric tissue (P1) (P = 0.035), the thickness of the abdominal wall (B1) (P = 0.017), and the preoperative albumin (P = 0.032), and the nomogram was established. AUC = 0.773 (0.645–0.901).ConclusionsThe RPD difficulty evaluation system based on the specific anatomical relationship between da Vinci’s laparoscopic robotic arm and tissues/organs in the operation area can be used as a predictive tool to evaluate the surgical difficulty of patients before operation and guide clinical practice.</p
    corecore