846 research outputs found
Exploitation of the coil-globule plasmid DNA transition induced by small changes in temperature, pH salt, and poly(ethylene glycol) compositions for directed partitioning in aqueous two-phase systems
In this study, the interplay of two linked equilibria is examined, one concerning an aqueous two-phase system (ATPS) composed of poly(ethylene glycol) (PEG) and salt employed to partition plasmid DNA (pDNA), and the other a potential structural transition of pDNA depending on PEG and salt concentration and other system parameters. The boundary conditions for pDNA partitioning are set by PEG and salt concentrations, PEG molecular weight, pH, and temperature. While investigating these parameters, it was found that a small increase/decrease of the respective values led to a drastic and significant change in pDNA behavior. This behavior could be attributed to a coil-globule transition of the pDNA triggered by the respective phase conditions. The combination of this structural change, aggregation effects linked to the transition process, and the electrostatic potential difference found in PEG-salt systems thus offers a sensitive way to separate nucleic acid forms on the basis of their unique property to undergo coil-globule transitions under distinct system properties
Antimicrobial prescription in cats in Switzerland before and after the introduction of an online antimicrobial stewardship tool: a trend towards more prudent unse
Temperature Based Process Characterization of Pharmaceutical Freeze-Thaw Operations
In biopharmaceutical production processes, freeze-thaw operations are used to ensure product integrity during long hold times, but they also introduce additional stresses such as freeze concentration gradients that might lead to a loss of protein activity. Process characterization of freeze-thaw operations at different scales should be conducted with attention to freezing time and boundary effects to ensure the product stability throughout the process and process development. Currently, process characterization often relies on one or very few temperature probes that detect freezing times based on raw temperature, which is largely influenced by freezing-point depression in case of concentrated solutions. A method to detect freezing based on the second derivative of temperature measurements from Fiber-Bragg-Grating sensors is presented to overcome this issue. The applicability of the method is demonstrated by process characterization of a novel small-scale freeze-thaw device with minimized boundary effects using freezing times of purified water and concentrated formulations. Freezing times varied from 35 to 81 min for temperatures between −60 and −20°C and impacted freeze concentration profiles. Furthermore, freezing time estimations based on the Plank equation revealed model limitations due to start-up temperature gradients, that can be corrected by an empirically extended Plank model. As a hypothesis, we conclude that freezing temperature, from a freeze concentration view, is less important in containers with small characteristic freezing distances such as freeze bags. Using a 2D-resolved temperature profile, a shift of the last point to freeze position from top to bottom of a container was observed when freezing above −30°C
Size-selective downstream processing of virus particles and non-enveloped virus-like particles
Non-enveloped virus-like particles (VLPs) are versatile protein nanoparticles with great potential for biopharmaceutical applications. However, conventional protein downstream processing (DSP) and platform processes are often not easily applicable due to the large size of VLPs and virus particles (VPs) in general. The application of size-selective separation techniques offers to exploit the size difference between VPs and common host-cell impurities. Moreover, size-selective separation techniques offer the potential for wide applicability across different VPs. In this work, basic principles and applications of size-selective separation techniques are reviewed to highlight their potential in DSP of VPs. Finally, specific DSP steps for non-enveloped VLPs and their subunits are reviewed as well as the potential applications and benefits of size-selective separation techniques are shown
Influence of image analysis strategy, cooling rate, and sample volume on apparent protein cloud-point temperature determination
The protein cloud-point temperature (T) is a known representative of protein–protein interaction strength and provides valuable information during the development and characterization of protein-based products, such as biopharmaceutics. A high-throughput low volume T detection method was introduced in preceding work, where it was concluded that the extracted value is an apparent T (T). As an understanding of the apparent nature is imperative to facilitate inter-study data comparability, the current work was performed to systematically evaluate the influence of 3 image analysis strategies and 2 experimental parameters (sample volume and cooling rate) on T detection of lysozyme. Different image analysis strategies showed that T is detectable by means of total pixel intensity difference and the total number of white pixels, but the latter is also able to extract the ice nucleation temperature. Experimental parameter variation showed a T depression for increasing cooling rates (0.1–0.5 °C/min), and larger sample volumes (5–24 μL). Exploratory thermographic data indicated this resulted from a temperature discrepancy between the measured temperature by the cryogenic device and the actual sample temperature. Literature validation confirmed that the discrepancy does not affect the relative inter-study comparability of the samples, regardless of the image analysis strategy or experimental parameters. Additionally, high measurement precision was demonstrated, as T changes were detectable down to a sample volume of only 5 μL and for 0.1 °C/min cooling rate increments. This work explains the apparent nature of the T detection method, showcases its detection precision, and broadens the applicability of the experimental setup
Raman spectroscopy as a process analytical technology to investigate biopharmaceutical freeze concentration processes
Freezing processes are a well-established unit operation in the biopharmaceutical industry to increase the shelf-life of protein-based drugs. While freezing reduces degradation reaction rates, it may also exert stresses such as freeze concentration. Macroscopic freeze concentration in large-scale freezing processes has been described thoroughly by examination of frozen bulk material, but the transient process leading to such freeze concentration profiles has not been monitored yet for biopharmaceutical solutions. In this study, Raman spectroscopy as a process analytical technology is demonstrated for model formulations containing monoclonal antibodies (mAbs) or bovine serum albumin (BSA) in varying concentrations of sucrose and buffer salts. Therefore, a Raman probe was immersed into a bulk volume at different heights, monitoring the freeze concentration in the liquid phase during the freezing processes. Partial least square regression models were used to quantitatively discriminate between the protein and excipients simultaneously. The freeze concentration profiles were dependend on freezing temperature and formulation with freeze concentrations up to 2.4-fold. Convection currents at the bottom of the freezing container were observed with a maximum height of 1 mm. Furthermore, freeze concentration was correlated with the sucrose concentration in a formulation. Analysis of the freeze concentration slope indicated diffusion from the bottom to the top of the container. In summary, Raman spectroscopy is a valuable tool for process validation of freeze concentration simulations and to overcome scale-dependent challenges
Investigation of Lysozyme Diffusion in Agarose Hydrogels Employing a Microfluidics-Based UV Imaging Approach
Hydrogels are polymer-based materials with a high water content. Due to their biocompatible and cell-friendly nature, they play a major role in a variety of biotechnological applications. For many of these applications, diffusibility is an essential property influencing the choice of material. We present an approach to estimate diffusion coefficients in hydrogels based on absorbance measurements of a UV area imaging system. A microfluidic chip with a y-junction was employed to generate a fluid-hydrogel interface and the diffusion of lysozyme from the fluid into the hydrogel phase was monitored. Employing automated image and data processing, analyte concentration profiles were generated from the absorbance measurements and fits with an analytical solution of Fick’s second law of diffusion were applied to estimate diffusion coefficients. As a case study, the diffusion of lysozyme in hydrogels made from different concentrations (0.5–1.5% (w/w)) of an unmodified and a low-melt agarose was investigated. The estimated diffusion coefficients for lysozyme were between 0.80 ± 0.04×10 m s for 1.5% (w/w) low-melt agarose and 1.14 ± 0.02×10 m s for 0.5% (w/w) unmodified agarose. The method proved sensitive enough to resolve significant differences between the diffusion coefficients in different concentrations and types of agarose. The microfluidic approach offers low consumption of analyte and hydrogel and requires only relatively simple instrumentation
Application of ultraviolet, visible, and infrared light imaging in protein-based biopharmaceutical formulation characterization and development studies
Imaging is increasingly more utilized as analytical technology in biopharmaceutical formulation research, with applications ranging from subvisible particle characterization to thermal stability screening and residual moisture analysis. This review offers a comprehensive overview of analytical imaging for scientists active in biopharmaceutical formulation research and development, where it presents the unique information provided by the ultraviolet (UV), visible (Vis), and infrared (IR) sections in the electromagnetic spectrum. The main body of this review consists of an outline of UV, Vis, and IR imaging techniques for several (bio)physical properties that are commonly determined during protein-based biopharmaceutical formulation characterization and development studies. The review concludes with a future perspective of applied imaging within the field of biopharmaceutical formulation research
Calibration-free PAT: Locating selective crystallization or precipitation sweet spot in screenings with multi-way PARAFAC models
When developping selective crystallization or precipitation processes,
biopharmaceutical modalities require empirical screenings and analytics
tailored to the specific needs of the target molecule. The multi-way
chemometric approach called parallel factor analysis (PARAFAC) coupled
with ultraviolet visible light (UV/Vis) spectroscopy is able to predict specific
concentrations and spectra from highly structured data sets without the need
for calibration samples and reference analytics. These calculated models can
provide exploratory information on pure species spectra and concentrations in
all analyzed samples by representing one model component with one species.
In this work, protein mixtures, monoclonal antibodies, and virus-like particles in
chemically defined and complex solutions were investigated in three high-
throughput crystallization or precipitation screenings with the aim to construct
one PARAFAC model per case. Spectroscopic data sets of samples after the
selective crystallization or precipitation, washing, and redissolution were
recorded and arranged into a four-dimensional data set per case study.
Different reference analytics and pure species spectra served as validation.
Appropriate spectral preprocessing parameters were found for all case studies
allowing even the application of this approach to the third case study in which
quantitative concentration analytics are missing. Regardless of the modality or
the number of species present in complex solutions, all models were able to
estimate the specific concentration and find the optimal process condition
regarding yield and product purity. It was shown that in complex solutions,
species demonstrating similar phase behavior can be clustered as one
component and described in the model. PARAFAC as a calibration-free
approach coupled with UV/Vis spectroscopy provides a fast overview of
species present in complex solution and of their concentration during
selective crystallization or precipitation, washing, and redissolution
Raman-based PAT for multi-attribute monitoring during VLP recovery by dual-stage CFF: attribute-specific spectral preprocessing for model transfer
- …