681 research outputs found
Evaluation of single root canals filled using the lateral compaction, tagger's hybrid, microseal and guttaflow techniques
The aim of this study was to determine the percentage of voids, gutta-percha and root canal sealer using 4 different filling techniques. Fifty-two extracted maxillary lateral incisors were prepared using the crown-down pressureless technique. The teeth were randomly divided in 4 groups (n=13): Lateral compaction (LC), Tagger's hybrid (TH), MicroSeal (MS) and GuttaFlow (GF) techniques. Horizontal cross-sections were made at the 2, 10 and 15 mm levels from the apex. Digital images of the root canal areas were acquired using a stereomicroscope and examined using the Image Tool 3.0 software. Statistical analysis was performed using the Kruskal-Wallis test (α=0.05). In general, a significant decrease in the gutta-percha filled area and increase of sealer area were observed at the apical level for all the evaluated techniques (p<0.05). With regard to the presence of voids, no significant difference was found. MS and TH techniques showed a larger gutta-percha filled area than LC and GF techniques at the coronal and middle third level (p<0.05). From the results of the present study, it may be concluded that the gutta-percha filled area of fillings decrease at the apical level, regardless of the filling technique used.O objetivo do estudo foi determinar a porcentagem de espaços vazios, guta-percha e cimento após a obturação por 4 diferentes técnicas. Cinquenta e dois incisivos laterais superiores humanos extraídos foram instrumentados pela técnica coroa-ápice sem pressão. Os dentes foram randomicamente divididos em 4 grupos (n=13): Condensação lateral (LC), Técnica híbrida de Tagger (TH), MicroSeal (MS) e GuttaFlow (GF). Foram feitas secções horizontais a 2, 10 e 15 mm do ápice. Imagens digitais foram obtidas dos canais por meio de estereomicroscópio e analisadas no programa Image Tool 3.0. A análise estatística foi feita utilizando o teste de Kruskal-Wallis (α=0,05). Em geral foi observado um significante decréscimo na área de guta-percha e um aumento na área de cimento para todas as técnicas analisadas (p<0,05). Com relação à presença de espaços vazios, não houve diferença estatística entre as técnicas (p>0,05). As técnicas MS e TH apresentaram área de guta-percha maior que as técnicas LC e GF nos terços médio e cervical (p<0,05). Após análise dos resultados foi possível concluir que a área de guta-percha nas obturações diminui em sentido apical, independente da técnica utilizada
Effectiveness of rotary or manual techniques for removing a 6-year-old filling material
The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill) , and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.O objetivo deste estudo foi avaliar a efetividade da instrumentação manual e rotatória na remoção de material obturador de canais radiculares de raízes palatinas de molares superiores humanos, em dois períodos de tempo. Vinte e quatro raízes foram instrumentadas e obturadas com guta-percha, cimento de óxido de zinco e eugenol e armazenadas em solução salina durante 6 anos. Outras 24 raízes foram tratadas da mesma maneira e armazenadas por uma semana. Os canais radiculares foram retratados usando limas manuais ou instrumentos rotatórios do Sistema ProTaper Universal. Radiografias periapicais foram feitas para mensurar a quantidade de material remanescente. Posteriormente as raízes foram clivadas e imagens microscópicas obtidas a partir de um microscópio clínico operatório foram digitalizadas. As imagens foram avaliadas através do software Autocad 2004 e área de material obturador remanescente foi mensurada. A Análise da Variância (Two-way) e o Teste T demonstraram não haver diferenças estatisticamente significantes entre a técnica manual e rotatória na remoção de material obturador. O terço apical mostrou a maior percentagem de remanescentes de material obturador, na análise radiográfica e microscópica quando comparado com os outros terços radiculares. Todos os canais revelaram resíduos de material obturador após o retratamento endodôntico. A análise microscópica foi mais efetiva do que a radiográfica na detecção de remanescente de obturação do canal radicular
Rat subcutaneous tissue response to MTA Fillapex® and Portland cement
The aim of this study was to evaluate the response of rat subcutaneous tissue to MTA Fillapex® (Angelus), an experimental root canal filling material based on Portland cement and propylene glycol (PCPG), and a zinc oxide, eugenol and iodoform (ZOEI) paste. These materials were placed in polyethylene tubes and implanted into the dorsal connective tissue of Wistar rats for 7 and 15 days. The specimens were stained with hematoxylin and eosin, and evaluated regarding inflammatory reaction parameters by optical microscopy. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated examiners for all experimental periods (kappa=0.96). The histological evaluation showed that all materials caused a moderate inflammatory reaction at 7 days, which subsided with time. A greater inflammatory reaction was observed at 7 days in the tubes filled with ZOEI paste. Tubes filled with MTA Fillapex presented some giant cells, macrophages and lymphocytes after 7 days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The tubes filled with PCPG showed similar results to those observed in MTA Fillapex. At 15 days, the inflammatory reaction was almost absent at the tissue, with several collagen fibers indicating normal tissue healing. Data were analyzed by the nonparametric Kruskal-Wallis test (?=0.05). Statistically significant difference (p<0.05) was found only between PCPG at 15 days and ZOEI at 7 days groups. No significant differences were observed among the other groups/periods (p>0.05). MTA Fillapex and Portland cement added with propylene glycol had greater tissue compatibility than the PCPG paste.O objetivo deste estudo foi avaliar a resposta do tecido subcutâneo de rato ao MTA Fillapex® (Angelus), a um cimento endodôntico experimental à base de cimento Portland e propilenoglicol, e à pasta de óxido de zinco e eugenol com iodofórmio. Estes materiais foram colocados em tubos de polietileno e implantados no tecido conjuntivo do dorso de ratos Wistar, por 7 e 15 dias. Os espécimes foram corados com hematoxilina e eosina e os parâmetros de reação inflamatória foram avaliados em microscópio óptico. A intensidade da resposta inflamatória provocada pelos cimentos foi analisada em todos os períodos por dois observadores previamente calibrados (kappa 0,96) e sem conhecimento dos grupos experimentais. O exame histológico mostrou que todos os materiais provocaram reação inflamatória moderada aos 7 dias que regrediu com o tempo. A maior resposta inflamatória do tecido foi observada aos 7 dias, nos tubos preenchidos com pasta de Óxido de Zinco e Eugenol com Iodofórmio. Os tubos com MTA Fillapex apresentaram algumas células gigantes, macrófagos e linfócitos após 7 dias. Aos 15 dias, a presença de fibroblastos e fibras de colágenas foi observada, indicando processo de cicatrização do tecido. Os tubos com o cimento Portland mostraram resultados semelhantes aos observados no grupo MTA Fillapex. Aos 15 dias, a reação inflamatória apresentada foi praticamente ausente, com muitas fibras colágenas, indicando cicatrização normal do tecido. A análise estatística mostrou diferença estatisticamente significante entre o grupo de cimento Portland (15 dias) e óxido de zinco eugenol com Iodofórmio (7 dias) (p<0,05). Nos outros grupos não houve diferença estatística significante. MTA Fillapex e cimento Portland são mais biocompatíveis do que os outros cimentos testados
19th World Conference on Open Learning and Distance Education
Todos os trabalhos se desenvolveram no Austria Center Vienna, o mais moderno centro de congressos da capital austríaca, adjacente ao complexo das Nações Unidas, na margem esquerda do Danúbio, a menos de quinze minutos de metro do centro da cidade.
Com mais de mil e trezentos participantes, na Conferência estiveram representados setenta e nove países, sendo trinta europeus, dezasseis asiáticos, quinze americanos, catorze africanos e quatro da zona do Pacífico. Em termos de representação individual, a Europa, com mais de 57% de presenças, foi a zona do globo mais visível. De salientar, contudo, a presença significativa de um elevado número de representantes de países em busca de desenvolvimento, de todos os continentes, da Letónia à Eslováquia, da Mongólia ao Vietname, da República Dominicana ao Equador, do Botswana à Tunísia, passando pelo Chade e pelo Togo
Antimicrobial activity of calcium hydroxide and chlorhexidine on intratubular Candida albicans
This study investigated the efficacy of calcium hydroxide and chlorhexidine gel for the elimination of intratubular Candida albicans (C. albicans). Human single-rooted teeth contaminated with C. albicans were treated with calcium hydroxide, 2% chlorhexidine gel, calcium hydroxide plus 2% chlorhexidine gel, or saline (0.9% sodium chloride) as a positive control. The samples obtained at depths of 0–100 and 100–200 µm from the root canal system were analyzed for C. albicans load by counting the number of colony forming units and for the percentage of viable C. albicans using fluorescence microscopy. First, the antimicrobial activity of calcium hydroxide and the 2% chlorhexidine gel was evaluated by counting the number of colony forming units. After 14 days of intracanal medication, there was a significant decrease in the number of C. albicans colony forming units at a depth of 0–100 µm with chlorhexidine treatment either with or without calcium hydroxide compared with the calcium hydroxide only treatment. However, there were no differences in the number of colony forming units at the 100–200 µm depth for any of the medications investigated. C. albicans viability was also evaluated by vital staining techniques and fluorescence microscopy analysis. Antifungal activity against C. albicans significantly increased at both depths in the chlorhexidine groups with and without calcium hydroxide compared with the groups treated with calcium hydroxide only. Treatments with only chlorhexidine or chlorhexidine in combination with calcium hydroxide were effective for elimination of C. albicansFAPESP 2007/00306-1FAPESP 2007/003061CAPESCAPE
Biocompatibility and setting time of CPM-MTA and white Portland cement clinker with or without calcium sulfate
To evaluate the biocompatibility and the setting time of Portland cement clinker with or without 2% or 5% calcium sulfate and MTA-CPM. Twenty-four mice (Rattus norvegicus) received subcutaneously polyethylene tubes filled with Portland cement clinker with or without 2% or 5% calcium sulfate and MTA. After 15, 30 and 60 days of implantation, the animals were killed and specimens were prepared for microscopic analysis. For evaluation of the setting time, each material was analyzed using Gilmore needles weighing 113.5 g and 456.5 g, according to the ASTM specification Number C266-08 guideline. Data were analyzed by ANOVA and Tukey's test for setting time and Kruskal-Wallis and Dunn test for biocompatibility at 5% significance level. Histologic observation showed no statistically significant difference of biocompatibility (p>0.05) among the materials in the subcutaneous tissues. For the setting time, clinker without calcium sulfate showed the shortest initial and final setting times (6.18 s/21.48 s), followed by clinker with 2% calcium sulfate (9.22 s/25.33 s), clinker with 5% calcium sulfate (10.06 s/42.46 s) and MTA (15.01 s/42.46 s). All the tested materials showed biocompatibility and the calcium sulfate absence shortened the initial and final setting times of the white Portland cement clinke
A IDEIA DE VETO POPULAR (PEOPLE'S VETO) DE TOM DONNELLY E A INSTRUMENTALIZAÇÃO DOS POSTULADOS DO CONSTITUCIONALISMO POPULAR
A Teoria do Constitucionalismo Popular defende a autoridade popular do exercício da interpretação constitucional. No entanto, percebe-se que pouco se elaborou quanto à viabilização e aplicação dos referidos preceitos no sistema constitucional americano, quiçá brasileiro. Para tanto, exsurge a ferramenta do veto popular para o fim de aplicação dos fundamentos do Popular Constitucionalism, amenizando-se a atual supremacia do judicial review e deslocado-se a autoridade para a figura do povo
A TEORIA DOS SISTEMAS DE LUHMANN APLICADA ÀS POLÍTICAS PÚBLICAS URBANAS
A forma de interpretar os problemas públicos e a sua assimilação pelo sistema político é tratada a partir da teoria sistêmica de Luhmann, notadamente no tocante às políticas públicas urbanas, necessidades apresentadas pelos cidadãos habitantes da cidade que são traduzidas em linguagem competente para a produção políticas urbanas capazes de concretizar as funções sociais da cidade
- …
