47 research outputs found

    Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    Get PDF
    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components

    Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: An experimental study

    Get PDF
    Today, the shoulder joint is the third most commonly replaced joint after the hip and knee joints and the incidence is increasing. In Sweden, 1863 primary Shoulder Arthroplasties and 195 revisions were performed in 2017. The most common diagnoses are Osteoarthritis and irreparable tears of the rotator cuff, with or without arthropathy, often referred to as cuff tear arthropathy. Different Shoulder Arthroplasty (SA) concepts include anatomical total shoulder arthroplasty (TSA), hemiarthroplasty (HSA) and reversed shoulder arthroplasty, but also humeral head resurfacing (HHR) and stemless arthroplasties. All concepts offer pain relief, improvement of function and in quality of life for the different diagnoses. Unfortunately, there are sometimes complications after SA. They involve periprosthetic joint infection, humeral and glenoid fractures, stress shielding, loosening of the glenoid and humeral component but also glenoid erosion and cuff rupture. Some of these complications are most common within 1 year after operation, some after several years, both may lead to a revision. This, together with the fact that new designs of implants and methods of fixation of SA continues to develop, stresses the importance of continuous monitoring of implant survival and follow-up. The overall aim of this thesis was to describe clinical examples of different methods to assess the outcome after Shoulder Arthroplasty. The most common methods are clinical examination, radiographic assessment, Patient Reported Outcome Measure (PROM), National Joint registries, where revisions are an important outcome, but also Clinical Trials. All of these methods are used in one or more of the 4 papers in this thesis and shows the complexity of the topic and the practical work. In paper I we used Radio Stereometric Analysis (RSA) in an experimental set-up and concluded that marker-free RSA can be used for a humeral head resurfacing arthroplasty. In paper II we used data from the Swedish Shoulder Arthroplasty Registry (SSAR) with PROM and revisions to conclude that age is the only factor that affects revision when comparing HSA and HHR. Paper III is a long-time follow-up of a Randomized controlled study where we used radiological assessment, PROM and revisions. The conclusion was that both TSA and HSA develop severe radiological changes 10 year after primary operation. Paper IV is a prospective RSA cohort study where we also evaluated PROM and revisions. The conclusion is that HHR seems to obtain a secure fixation in the humerus, after an initial migration. But also that the prostheses shows continuous glenoid wear. The main conclusion of this thesis is that patient’s operated with SA needs continuous monitoring and several methods may be used to evaluate the outcome

    The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures

    Get PDF
    Background and purpose: The application of radiostereometric analysis (RSA) to monitor stability of tibial plateau fractures during healing is both limited and yet to be validated. We therefore evaluated the accuracy and precision of RSA in a tibial plateau fracture model. Methods: Combinations of 3, 6, and 9 markers in a lateral condyle fracture were evaluated with reference to 6 proximal tibial arrangements. Translation and rotation accuracy was assessed with displacement-controlled stages, while precision was assessed with dynamic double examinations. A comparison of error according to marker number and arrangement was completed with 2-way ANOVA models. Results: The results were improved using more tantalum markers in each segment. In the fracture fragment, marker scatter in all axes was achieved by a circumferential arrangement (medial, anterior, and lateral) of the tantalum markers above the fixation devices. Markers placed on either side of the tibial tuberosity and in the medial aspect of the fracture split represented the proximal tibial reference segment best. Using 6 markers with this distribution in each segment, the translation accuracy (root mean square error) was less than 37 μm in all axes. The precision (95% confidence interval) was less than ± 16 μm in all axes in vitro. Rotation, tested around the x-axis, had an accuracy of less than 0.123° and a precision of ± 0.024°. Interpretation: RSA is highly accurate and precise in the assessment of lateral tibial plateau fracture fragment movement. The validation of our center's RSA system provides evidence to support future clinical RSA fracture studies.Lucian B Solomon, Aaron W Stevenson, Stuart A Callary, Thomas R Sullivan, Donald W Howie, and Mellick J Chehad

    Trombocitose essencial: o que é essencial saber

    No full text
    A trombocitose essencial (TE) faz parte do grupo de síndromes mieloproliferativas (SMP) cromossomo Philadelphia(Ph) negativas. Caracteriza-se pela hiperproliferação megacariocítica com consequente trombocitose periférica, favorecendo fenômenos trombo-hemorrágicos. Esta entidade estava esquecida até meados de 2005, quando as recentes publicações sobre as alterações moleculares na atividade da enzima tirosina quinase, JAK2, desencadeou um novo interesse sobre a patogenia, aspectos clínicos e terapêuticos da TE. A identificação das mutações de JAK2 e do gene MPL W515K, W515L e S505N impulsionou a nova proposta da Organização Mundial de Saúde (OMS) para reformular os critérios diagnósticos, reduzindo o número de plaquetas para 450x10(9)/L. O alicerce do tratamento são agentes redutores das contagens plaquetárias: hidroxiureia, anagrelide ou interferon associados à prevenção das complicações trombo-hemorrágicas. Não há um tratamento curativo para a TE, mas despontam perspectivas de que terapias alvo, bloqueadoras da mutação JAK2, possam incrementar o desfecho da doença. Inibidores de JAK2, específicos e inespecíficos, estão sendo estudados em fase I e II e parecem promissores num futuro próximo
    corecore