2,857 research outputs found
Bessel beam propagation: Energy localization and velocity
The propagation of a Bessel beam (or Bessel-X wave) is analyzed on the basis
of a vectorial treatment. The electric and magnetic fields are obtained by
considering a realistic situation able to generate that kind of scalar field.
Specifically, we analyze the field due to a ring-shaped aperture over a
metallic screen on which a linearly polarized plane wave impinges. On this
basis, and in the far field approximation, we can obtain information about the
propagation of energy flux and the velocity of the energy.Comment: 6 pages, 4 figure
Delay in diabetic retinopathy screening increases the rate of detection of referable diabetic retinopathy
Aims - To assess whether there is a relationship between delay in retinopathy screening after diagnosis of Type 2 diabetes and level of retinopathy detected.
Methods - Patients were referred from 88 primary care practices to an English National Health Service diabetic eye screening programme. Data for screened patients were extracted from the primary care databases using semi-automated data collection algorithms supplemented by validation processes. The programme uses two-field mydriatic digital photographs graded by a quality assured team.
Results - Data were available for 8183 screened patients with diabetes newly diagnosed in 2005, 2006 or 2007. Only 163 with Type 1 diabetes were identified and were insufficient for analysis. Data were available for 8020 with newly diagnosed Type 2 diabetes. Of these, 3569 were screened within 6 months, 2361 between 6 and 11 months, 1058 between 12 and 17 months, 366 between 18 and 23 months, 428 between 24 and 35 months, and 238 at 3 years or more after diagnosis. There were 5416 (67.5%) graded with no retinopathy, 1629 (20.3%) with background retinopathy in one eye, 753 (9.4%) with background retinopathy in both eyes and 222 (2.8%) had referable diabetic retinopathy. There was a significant trend (P = 0.0004) relating time from diagnosis to screening detecting worsening retinopathy. Of those screened within 6 months of diagnosis, 2.3% had referable retinopathy and, 3 years or more after diagnosis, 4.2% had referable retinopathy.
Conclusions - The rate of detection of referable diabetic retinopathy is elevated in those who were not screened promptly after diagnosis of Type 2 diabetes
Why and when the Minkowski's stress tensor can be used in the problem of Casimir force acting on bodies embedded in media
It is shown that the criticism by Raabe and Welsch of the
Dzyaloshinskii-Lifshitz-Pitaevskii theory of the van der Waals-Casimir forces
inside a medium is based on misunderstandings. It is explained why and at which
conditions one can use the ''Minkowski-like '' stress tensor for calculations
of the forces. The reason, why approach of Raabe and Welsch is incorrect, is
discussed.Comment: Comment, 2 pages. 2 misprints were correcte
Photonic band mixing in linear chains of optically coupled micro-spheres
The paper deals with optical excitations arising in a one-dimensional chain
of identical spheres due optical coupling of whispering gallery modes (WGM).
The band structure of these excitations depends significantly on the
inter-mixing between WGMs characterized by different values of angular quantum
number, . We develop a general theory of the photonic band structure of
these excitations taking these effects into account and applied it to several
cases of recent experimental interest. In the case of bands originating from
WQMs with the angular quantum number of the same parity, the calculated
dispersion laws are in good qualitative agreement with recent experiment
results. Bands resulting from hybridization of excitations resulting from
whispering gallery modes with different parity of exhibits anomalous
dispersion properties characterized by a gap in the allowed values of
\emph{wave numbers} and divergence of group velocity.Comment: RevTex, 28 pages, 7 Figure
Force on a neutral atom near conducting microstructures
We derive the non-retarded energy shift of a neutral atom for two different
geometries. For an atom close to a cylindrical wire we find an integral
representation for the energy shift, give asymptotic expressions, and
interpolate numerically. For an atom close to a semi-infinite halfplane we
determine the exact Green's function of the Laplace equation and use it derive
the exact energy shift for an arbitrary position of the atom. These results can
be used to estimate the energy shift of an atom close to etched microstructures
that protrude from substrates.Comment: 7 pages, 5 figure
Exponential beams of electromagnetic radiation
We show that in addition to well known Bessel, Hermite-Gauss, and
Laguerre-Gauss beams of electromagnetic radiation, one may also construct
exponential beams. These beams are characterized by a fall-off in the
transverse direction described by an exponential function of rho. Exponential
beams, like Bessel beams, carry definite angular momentum and are periodic
along the direction of propagation, but unlike Bessel beams they have a finite
energy per unit beam length. The analysis of these beams is greatly simplified
by an extensive use of the Riemann-Silberstein vector and the Whittaker
representation of the solutions of the Maxwell equations in terms of just one
complex function. The connection between the Bessel beams and the exponential
beams is made explicit by constructing the exponential beams as wave packets of
Bessel beams.Comment: Dedicated to the memory of Edwin Powe
Comment on "Effects of spatial dispersion on electromagnetic surface modes and on modes associated with a gap between two half spaces"
Recently Bo E. Sernelius [Phys. Rev. B {\bf 71}, 235114 (2005)] investigated
the effects of spatial dispersion on the thermal Casimir force between two
metal half spaces. He claims that incorporating spatial dispersion results in a
negligible contribution from the transverse electric mode at zero frequency as
compared to the transverse magnetic mode. We demonstrate that this conclusion
is not reliable because, when applied to the Casimir effect, the approximate
description of spatial dispersion used is unjustified.Comment: 9 pages, minor corrections in accordance with the journal publication
have been mad
System-level and patient-level explanations for non-attendance at diabetic retinopathy screening in Sutton and Merton (London, UK): a qualitative analysis of a service evaluation
Objectives: Non-attendance at diabetic retinopathy screening has financial implications for screening programmes and potential clinical costs to patients. We sought to identify explanations for why patients had never attended a screening appointment (never attendance) in one programme. Design: Qualitative analysis of a service evaluation. Setting: One South London (UK) diabetic eye screening programme. Participants and procedure: Patients who had been registered with one screening programme for at least 18 months and who had never attended screening within the programme were contacted by telephone to ascertain why this was the case. Patients’ general practices were also contacted for information about why each patient may not have attended. Framework analysis was used to interpret responses. Results: Of the 296 patients, 38 were not eligible for screening and of the 258 eligible patients, 159 were not contactable (31 of these had phone numbers that were not in use). We obtained reasons from patients/general practices/clinical notes for non-attendance for 146 (57%) patients. A number of patient-level and system-level factors were given to explain non-attendance. Patient-level factors included having other commitments, being anxious about screening, not engaging with any diabetes care and being misinformed about screening. System-level factors included miscommunication about where the patient lives, their clinical situation and practical problems that could have been overcome had their existence been shared between programmes. Conclusions: This service evaluation provides unique insight into the patient-level and system-level reasons for never attendance at diabetic retinopathy screening. Improved sharing of relevant information between providers has the potential to facilitate increased uptake of screening. Greater awareness of patient-level barriers may help providers offer a more accessible service
Delay in diabetic retinopathy screening increases the rate of detection of referable diabetic retinopathy
Aims - To assess whether there is a relationship between delay in retinopathy screening after diagnosis of Type 2 diabetes and level of retinopathy detected.\ud
\ud
\ud
Methods - Patients were referred from 88 primary care practices to an English National Health Service diabetic eye screening programme. Data for screened patients were extracted from the primary care databases using semi-automated data collection algorithms supplemented by validation processes. The programme uses two-field mydriatic digital photographs graded by a quality assured team.\ud
\ud
\ud
Results - Data were available for 8183 screened patients with diabetes newly diagnosed in 2005, 2006 or 2007. Only 163 with Type 1 diabetes were identified and were insufficient for analysis. Data were available for 8020 with newly diagnosed Type 2 diabetes. Of these, 3569 were screened within 6 months, 2361 between 6 and 11 months, 1058 between 12 and 17 months, 366 between 18 and 23 months, 428 between 24 and 35 months, and 238 at 3 years or more after diagnosis. There were 5416 (67.5%) graded with no retinopathy, 1629 (20.3%) with background retinopathy in one eye, 753 (9.4%) with background retinopathy in both eyes and 222 (2.8%) had referable diabetic retinopathy. There was a significant trend (P = 0.0004) relating time from diagnosis to screening detecting worsening retinopathy. Of those screened within 6 months of diagnosis, 2.3% had referable retinopathy and, 3 years or more after diagnosis, 4.2% had referable retinopathy.\ud
\ud
\ud
Conclusions - The rate of detection of referable diabetic retinopathy is elevated in those who were not screened promptly after diagnosis of Type 2 diabetes
- …
