835 research outputs found
Measurements of the Cerenkov light emitted by a TeO2 crystal
Bolometers have proven to be good instruments to search for rare processes
because of their excellent energy resolution and their extremely low intrinsic
background. In this kind of detectors, the capability of discriminating alpha
particles from electrons represents an important aspect for the background
reduction. One possibility for obtaining such a discrimination is provided by
the detection of the Cerenkov light which, at the low energies of the natural
radioactivity, is only emitted by electrons. In this paper, the results of the
analysis of the light emitted by a TeO2 crystal at room temperature when
transversed by a cosmic ray are reported. Light is promptly emitted after the
particle crossing and a clear evidence of its directionality is also found.
These results represent a strong indication that Cerenkov light is the main, if
not even the only, component of the light signal in a TeO2 crystal. They open
the possibility to make large improvements in the performance of experiments
based on this kind of material
Measurements and optimization of the light yield of a TeO crystal
Bolometers have proven to be good instruments to search for rare processes
because of their excellent energy resolution and their extremely low intrinsic
background. In this kind of detectors, the capability of discriminating alpha
particles from electrons represents an important aspect for the background
reduction. One possibility for obtaining such a discrimination is provided by
the detection of the Cherenkov light which, at the low energies of the natural
radioactivity, is only emitted by electrons. This paper describes the method
developed to evaluate the amount of light produced by a crystal of TeO when
hit by a 511 keV photon. The experimental measurements and the results of a
detailed simulation of the crystal and the readout system are shown and
compared. A light yield of about 52 Cherenkov photons per deposited MeV was
measured. The effect of wrapping the crystal with a PTFE layer, with the aim of
maximizing the light collection, is also presented
First bolometric measurement of the two neutrino double beta decay of Mo with a ZnMoO crystals array
The large statistics collected during the operation of a ZnMoO array, for
a total exposure of 1.3 kg day of Mo, allowed the first
bolometric observation of the two neutrino double beta decay of Mo. The
observed spectrum of each crystal was reconstructed taking into account the
different background contributions due to environmental radioactivity and
internal contamination. The analysis of coincidences between the crystals
allowed the assignment of constraints to the intensity of the different
background sources, resulting in a reconstruction of the measured spectrum down
to an energy of 300 keV. The half-life extracted from the data is
T= [7.15 0.37 (stat) 0.66 (syst)] 10
y.Comment: 6 pages, 2 figure, Accepted for publication in Journal of Physics G:
Nuclear and Particle Physic
TeO bolometers with Cherenkov signal tagging: towards next-generation neutrinoless double beta decay experiments
CUORE, an array of 988 TeO bolometers, is about to be one of the most
sensitive experiments searching for neutrinoless double-beta decay. Its
sensitivity could be further improved by removing the background from
radioactivity. A few years ago it has been pointed out that the signal from
s can be tagged by detecting the emitted Cherenkov light, which is not
produced by s. In this paper we confirm this possibility. For the first
time we measured the Cherenkov light emitted by a CUORE crystal, and found it
to be 100 eV at the -value of the decay. To completely reject the
background, we compute that one needs light detectors with baseline noise below
20 eV RMS, a value which is 3-4 times smaller than the average noise of the
bolometric light detectors we are using. We point out that an improved light
detector technology must be developed to obtain TeO bolometric experiments
able to probe the inverted hierarchy of neutrino masses.Comment: 5 pages, 4 figures. Added referee correction
Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests
A prototype for a sampling calorimeter made out of cerium fluoride crystals
interleaved with tungsten plates, and read out by wavelength-shifting fibres,
has been exposed to beams of electrons with energies between 20 and 150 GeV,
produced by the CERN Super Proton Synchrotron accelerator complex. The
performance of the prototype is presented and compared to that of a Geant4
simulation of the apparatus. Particular emphasis is given to the response
uniformity across the channel front face, and to the prototype's energy
resolution.Comment: 6 pages, 6 figures, Submitted to NIM
First array of enriched ZnSe bolometers to search for double beta decay
The R&D activity performed during the last years proved the potential of ZnSe
scintillating bolometers to the search for neutrino-less double beta decay,
motivating the realization of the first large-mass experiment based on this
technology: CUPID-0. The isotopic enrichment in Se, the ZnSe
crystals growth, as well as the light detectors production have been
accomplished, and the experiment is now in construction at Laboratori Nazionali
del Gran Sasso (Italy). In this paper we present the results obtained testing
the first three ZnSe crystals operated as scintillating bolometers, and
we prove that their performance in terms of energy resolution, background
rejection capability and intrinsic radio-purity complies with the requirements
of CUPID-0
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered
The CMS ECAL Barrel HV system
The CMS electromagnetic calorimeter (ECAL) comprises 75848 scintillating lead tungstate crystals. 61200 crystals are contained in the ECAL Barrel section and are read out by avalanche photodiode (APD) with internal gain of about 50. This gain is achieved with a high voltage (HV) of about 400 Volts. The gain stability requirement implies a supply voltage stable to within 0.01%. We describe our experience with the installed Barrel HV power supply system, which has been used for data taking since 2008
ZnMoO4: a promising bolometer for neutrinoless double beta decay searches
We investigate the performances of two ZnMoO4 scintillating crystals operated
as bolometers, in view of a next generation experiment to search the
neutrinoless double beta decay of Mo-100. We present the results of the alpha
vs beta/gamma discrimination, obtained through the scintillation light as well
as through the study of the shape of the thermal signal alone. The
discrimination capability obtained at the 2615 keV line of Tl-208 is 8 sigma,
using the heat-light scatter plot, while it exceeds 20 sigma using the shape of
the thermal pulse alone. The achieved FWHM energy resolution ranges from 2.4
keV (at 238 keV) to 5.7 keV (at 2615 keV). The internal radioactive
contaminations of the ZnMoO4 crystals were evaluated through a 407 hours
background measurement. The obtained limit is < 32 microBq/kg for Th-228 and
Ra-226. These values were used for a Monte Carlo simulation aimed at evaluating
the achievable background level of a possible, future array of enriched ZnMoO4
crystals.Comment: 9 pages, 8 figure
- …