5,925 research outputs found
Indications for Catheter-Directed Thrombolysis in the Management of Acute Proximal Deep Venous Thrombosis
Deep vein thromboses (DVTs) cause significant morbidity and mortality in the general population. Oral anticoagulation therapy may reduce thrombus propagation but does not cause clot lysis and therefore does not prevent postthrombotic syndrome (PTS). Catheter-directed thrombolysis (CDT) can be used to treat DVTs as an adjunct to medical therapy, but there is no consensus defining exact indications. Current evidence suggests that CDT can reduce clot burden and DVT recurrence and consequently prevents the formation of PTS compared with systemic anticoagulation. Appropriate indications include younger individuals with acute proximal thromboses, a long life expectancy, and relatively few comorbidities. Limb-threatening thromboses may also be treated with CDT, although the subsequent mortality remains high. A number of randomized controlled trials are currently under way comparing the longer-term outcomes of CDT compared with anticoagulation alone. Initial reports suggest that venous patency and valvular function are better maintained after CDT. The effectiveness of combined pharmacomechanical thrombectomy and the role of vena cava filters need to be investigated further before strong recommendations can be made. The reported short-term outcomes following catheter-based intervention for DVT are encouraging in selected patients. Further evidence is required to establish long-term benefits and cost-effectiveness
Signal Modeling in the Far-Infrared Region for Nondestructive Evaluation Applicatinos
Terahertz radiation (a.k.a. T‐ray) has emerged as a powerful inspection technique in recent years. It extends into the lower region of far‐infrared in the electromagnetic spectrum, and has been proven very effective in many NDE applications. T‐ray is particularly useful in some areas where accessibility is difficult or even not possible for other conventional NDE methods. Here we report a modeling effort of T‐ray signal in one such application: the detection of “hidden delamination”, a special situation that a delamination was shadowed by another. This special case was experimentally simulated by two parallel saw‐cuts in glass composites. In this paper, we also explore the feasibility of combing T‐ray and Fourier transform infrared spectroscopy using a unified least‐squares scheme for material characterization
Recommended from our members
Effect of Endovascular Aneurysm Repair on the Volume-Outcome Relationship in Aneurysm Repair
Background— We aim to quantify the relationship between the annual caseload (volume) and outcome from elective endovascular (EVR) or open repair of abdominal aortic aneurysms (AAAs) in England between 2005 and 2007.
Methods and Results— Individual patient data were obtained from the Hospital Episode Statistics. Statistical methods included multiple logistic regression models, mortality control charts, and safety plots to determine the nature of any relationship between volume and outcome. The case-mix between hospitals of different sizes was examined using observed and expected values for in-hospital mortality. Outcome measures included in-hospital mortality and hospital length of stay. Between 2005 and 2007, a total of 57 587 patients were admitted to hospitals in England with a diagnosis of AAA, and 11 574 underwent AAA repair. There were 7313 elective AAA repairs, of which 5668 (78%) were open and 1645 (22%) were EVR. In-hospital mortality rates were 5.63% for all elective AAA repairs with rates of 6.18% for open repair and 3.77% for EVR (odds ratio, 0.676; 95% CI, 0.501 to 0.913; P=0.011). High-volume aneurysm services were associated with significantly lower mortality rates overall (0.991; 0.988 to 0.994; P<0.0001), for open repairs (0.994; 0.991 to 0.998; P=0.0008), and EVR (0.989; 0.982 to 0.995; P=0.0007). Large endovascular units had low mortality rates for open repairs.
Conclusion— A strong relationship existed between the volume of surgery performed and outcome from both open and endovascular aneurysm repairs. These data support the concept that abdominal aortic surgery should be performed in specialized units that meet a minimum volume threshold
Thresholds for Abdominal Aortic Aneurysm Repair in England and the United States.
Background Thresholds for repair of abdominal aortic aneurysms vary considerably among countries. Methods We examined differences between England and the United States in the frequency of aneurysm repair, the mean aneurysm diameter at the time of the procedure, and rates of aneurysm rupture and aneurysm-related death. Data on the frequency of repair of intact (nonruptured) abdominal aortic aneurysms, in-hospital mortality among patients who had undergone aneurysm repair, and rates of aneurysm rupture during the period from 2005 through 2012 were extracted from the Hospital Episode Statistics database in England and the U.S. Nationwide Inpatient Sample. Data on the aneurysm diameter at the time of repair were extracted from the U.K. National Vascular Registry (2014 data) and from the U.S. National Surgical Quality Improvement Program (2013 data). Aneurysm-related mortality during the period from 2005 through 2012 was determined from data obtained from the Centers for Disease Control and Prevention and the U.K. Office of National Statistics. Data were adjusted with the use of direct standardization or conditional logistic regression for differences between England and the United States with respect to population age and sex. Results During the period from 2005 through 2012, a total of 29,300 patients in England and 278,921 patients in the United States underwent repair of intact abdominal aortic aneurysms. Aneurysm repair was less common in England than in the United States (odds ratio, 0.49; 95% confidence interval [CI], 0.48 to 0.49; P<0.001), and aneurysm-related death was more common in England than in the United States (odds ratio, 3.60; 95% CI, 3.55 to 3.64; P<0.001). Hospitalization due to an aneurysm rupture occurred more frequently in England than in the United States (odds ratio, 2.23; 95% CI, 2.19 to 2.27; P<0.001), and the mean aneurysm diameter at the time of repair was larger in England (63.7 mm vs. 58.3 mm, P<0.001). Conclusions We found a lower rate of repair of abdominal aortic aneurysms and a larger mean aneurysm diameter at the time of repair in England than in the United States and lower rates of aneurysm rupture and aneurysm-related death in the United States than in England. (Funded by the Circulation Foundation and others.)
Measuring Accuracy of Automated Parsing and Categorization Tools and Processes in Digital Investigations
This work presents a method for the measurement of the accuracy of evidential
artifact extraction and categorization tasks in digital forensic
investigations. Instead of focusing on the measurement of accuracy and errors
in the functions of digital forensic tools, this work proposes the application
of information retrieval measurement techniques that allow the incorporation of
errors introduced by tools and analysis processes. This method uses a `gold
standard' that is the collection of evidential objects determined by a digital
investigator from suspect data with an unknown ground truth. This work proposes
that the accuracy of tools and investigation processes can be evaluated
compared to the derived gold standard using common precision and recall values.
Two example case studies are presented showing the measurement of the accuracy
of automated analysis tools as compared to an in-depth analysis by an expert.
It is shown that such measurement can allow investigators to determine changes
in accuracy of their processes over time, and determine if such a change is
caused by their tools or knowledge.Comment: 17 pages, 2 appendices, 1 figure, 5th International Conference on
Digital Forensics and Cyber Crime; Digital Forensics and Cyber Crime, pp.
147-169, 201
Lessons from Love-Locks: The archaeology of a contemporary assemblage
This document is the Accepted Manuscript version. The final, definitive version of this paper has been published in Journal of Material Culture, November 2017, published by SAGE Publishing, All rights reserved.Loss of context is a challenge, if not the bane, of the ritual archaeologist’s craft. Those who research ritual frequently encounter difficulties in the interpretation of its often tantalisingly incomplete material record. Careful analysis of material remains may afford us glimpses into past ritual activity, but our often vast chronological separation from the ritual practitioners themselves prevent us from seeing the whole picture. The archaeologist engaging with structured deposits, for instance, is often forced to study ritual assemblages post-accumulation. Many nuances of its formation, therefore, may be lost in interpretation. This paper considers what insights an archaeologist could gain into the place, people, pace, and purpose of deposition by recording an accumulation of structured deposits during its formation, rather than after. To answer this, the paper will focus on a contemporary depositional practice: the love-lock. This custom involves the inscribing of names/initials onto a padlock, its attachment to a bridge or other public structure, and the deposition of the corresponding key into the water below; a ritual often enacted by a couple as a statement of their romantic commitment. Drawing on empirical data from a three-year diachronic site-specific investigation into a love-lock bridge in Manchester, UK, the author demonstrates the value of contemporary archaeology in engaging with the often enigmatic material culture of ritual accumulations.Peer reviewe
Uptake and transport of novel amphiphilic polyelectrolyte-insulin nanocomplexes by caco-2 cells - towards oral insulin
“The original publication is available at www.springerlink.com”. Copyright SpringerPurpose: The influence of polymer architecture on cellular uptake and transport across Caco-2 cells of novel amphiphilic polyelectrolyte-insulin nanocomplexes was investigated. Method: Polyallylamine (PAA) (15 kDa) was grafted with palmitoyl chains (Pa) and subsequently modified with quaternary ammonium moieties (QPa). These two amphiphilic polyelectrolytes (APs) were tagged with rhodamine and their uptake by Caco-2 cells or their polyelectrolyte complexes (PECs) with fluorescein isothiocyanate-insulin (FITC-insulin) uptake were investigated using fluorescence microscopy. The integrity of the monolayer was determined by measurement of transepithelial electrical resistance (TEER). Insulin transport through Caco-2 monolayers was determined during TEER experiments. Result: Pa and insulin were co-localised in the cell membranes while QPa complexes were found within the cytoplasm. QPa complex uptake was not affected by calcium, cytochalasin D or nocodazole. Uptake was reduced by co-incubation with sodium azide, an active transport inhibitor. Both polymers opened tight junctions reversibly where the TEER values fell by up to 35 % within 30 minutes incubation with Caco-2 cells. Insulin transport through monolayers increased when QPa was used (0.27 ngmL-1 of insulin in basal compartment) compared to Pa (0.14 ngmL-1 of insulin in basal compartment) after 2 hours. Conclusion: These APs have been shown to be taken up by Caco-2 cells and reversibly open tight cell junctions. Further work is required to optimise these formulations with a view to maximising their potential to facilitate oral delivery of insulin.Peer reviewe
Identification and validation of oncologic miRNA biomarkers for Luminal A-like breast cancer
Introduction: Breast cancer is a common disease with distinct tumor subtypes phenotypically characterized by ER and HER2/neu receptor status. MiRNAs play regulatory roles in tumor initiation and progression, and altered miRNA expression has been demonstrated in a variety of cancer states presenting the potential for exploitation as cancer biomarkers. Blood provides an excellent medium for biomarker discovery. This study investigated systemic miRNAs differentially expressed in Luminal A-like (ER+PR+HER2/neu-) breast cancer and their effectiveness as oncologic biomarkers in the clinical setting. Methods: Blood samples were prospectively collected from patients with Luminal A-like breast cancer (n=54) and controls (n=56). RNA was extracted, reverse transcribed and subjected to microarray analysis (n=10 Luminal A-like; n=10 Control). Differentially expressed miRNAs were identified by artificial neural network (ANN) data-mining algorithms. Expression of specific miRNAs was validated by RQ-PCR (n=44 Luminal A; n=46 Control) and potential relationships between circulating miRNA levels and clinicopathological features of breast cancer were investigated. Results: Microarray analysis identified 76 differentially expressed miRNAs. ANN revealed 10 miRNAs for further analysis ( miR-19b, miR-29a, miR-93, miR-181a, miR-182, miR-223, miR-301a, miR-423-5p, miR-486-5 and miR-652 ). The biomarker potential of 4 miRNAs ( miR-29a, miR-181a , miR-223 and miR-652 ) was confirmed by RQ-PCR, with significantly reduced expression in blood of women with Luminal A-like breast tumors compared to healthy controls (p=0.001, 0.004, 0.009 and 0.004 respectively). Binary logistic regression confirmed that combination of 3 of these miRNAs ( miR-29a, miR-181a and miR-652 ) could reliably differentiate between cancers and controls with an AUC of 0.80. Conclusion: This study provides insight into the underlying molecular portrait of Luminal A-like breast cancer subtype. From an initial 76 miRNAs, 4 were validated with altered expression in the blood of women with Luminal A-like breast cancer. The expression profiles of these 3 miRNAs, in combination with mammography, has potential to facilitate accurate subtype- specific breast tumor detection
Recommended from our members
Endovascular aneurysm sealing for the treatment of ruptured abdominal aortic aneurysms.
PURPOSE: To assess the feasibility and report preliminary results of ruptured abdominal aortic aneurysm (rAAA) repair with endovascular aneurysm sealing (EVAS), a novel therapeutic alternative whose feasibility has not been established in rAAAs due to the unknown effects of the rupture site on the ability to achieve sealing. CASE REPORT: Between December 2013 and April 2014, 5 patients (median age 71 years, range 57-90; 3 men) with rAAAs were treated with the Nellix EVAS system at a single institution. Median aneurysm diameter was 70 mm (range 67-91). Aneurysm morphology in 4 of the 5 patients was noncompliant with instructions for use (IFU) for both EVAS and standard stent-grafts; the remaining patient was outside the IFU for standard stent-grafts but treated with EVAS under standard IFU for the Nellix system. Median Hardman index was 2 (range 0-3). Two patients died of multiorgan failure after re-laparotomy and intraoperative cardiac arrest, respectively. Among survivors, all devices were patent with no signs of endoleak or failed aneurysm sac sealing at 6 months (median follow-up 9.2 months). CONCLUSION: EVAS for the management of infrarenal rAAAs appears feasible. The use of EVAS in emergency repairs may broaden the selection criteria of the current endovascular strategy to include patients with more complex aneurysm morphology
Evaluation of Phage Display Discovered Peptides as Ligands for Prostate-Specific Membrane Antigen (PSMA)
The aim of this study was to identify potential ligands of PSMA suitable for further development as novel PSMA-targeted peptides using phage display technology. The human PSMA protein was immobilized as a target followed by incubation with a 15-mer phage display random peptide library. After one round of prescreening and two rounds of screening, high-stringency screening at the third round of panning was performed to identify the highest affinity binders. Phages which had a specific binding activity to PSMA in human prostate cancer cells were isolated and the DNA corresponding to the 15-mers were sequenced to provide three consensus sequences: GDHSPFT, SHFSVGS and EVPRLSLLAVFL as well as other sequences that did not display consensus. Two of the peptide sequences deduced from DNA sequencing of binding phages, SHSFSVGSGDHSPFT and GRFLTGGTGRLLRIS were labeled with 5-carboxyfluorescein and shown to bind and co-internalize with PSMA on human prostate cancer cells by fluorescence microscopy. The high stringency requirements yielded peptides with affinities KD∼1 μM or greater which are suitable starting points for affinity maturation. While these values were less than anticipated, the high stringency did yield peptide sequences that apparently bound to different surfaces on PSMA. These peptide sequences could be the basis for further development of peptides for prostate cancer tumor imaging and therapy. © 2013 Shen et al
- …
