111 research outputs found

    Diving deep into digital literacy:emerging methods for research

    Get PDF
    Literacy studies approaches have tended to adopt a position which enables ethnographic explorations of a wide range of ‘literacies’. An important issue arising is the new challenge required for researchers to capture, manage, and analyse data that highlight the unique character of practices around texts in digital environments. Such inquiries, we argue, require multiple elements of data to be captured and analysed as part of effective literacy ethnographies. These include such things as the unfolding of digital texts, the activities around them, and features of the surrounding social and material environment. This paper addresses these methodological issues drawing from three educationally focused studies, and reporting their experiences and insights within uniquely different contexts. We deal with the issue of adopting new digital methods for literacy research through the notion of a ‘deep dive’ to explore educational tasks in classrooms. Through a discussion of how we approached the capture and analysis of our data, we present methods to better understand digital literacies in education. We then outline challenges posed by our methods, how they can be used more broadly for researching interaction in digital environments, and how they augment transdisciplinary debates and trends in research methods

    Challenges and potentials of forward osmosis process in the treatment of wastewater

    Full text link
    © 2019, © 2019 Taylor & Francis Group, LLC. An emerging osmotically driven membrane process, forward osmosis has attracted growing attention in the field of desalination and wastewater treatment. The present study provides a critical review of the forward osmosis process for wastewater treatment focusing on most recent studies. Forward osmosis is one of the technologies that has been widely studied for the treatment of a wide range of wastewater because of its low fouling and energy consumption compared to conventional techniques for wastewater treatment. To date, forward osmosis has limited applications in the field of wastewater treatment due to several technical and economic concerns. Although membrane cost is one of the critical issues that limit the commercial application of forward osmosis, there are other obstacles such as membrane fouling, finding an ideal draw solution that can easily be recycled, concentration polarization and reverse salt diffusion. Innovative technologies for in-situ real-time fouling monitoring can give us new insights into fouling mechanisms and fouling control strategies in forward osmosis. This study evaluated recent advancements in forward osmosis technology for wastewater treatment and the main challenges that need to be addressed in future research work

    A review of fouling mechanisms, control strategies and real-time fouling monitoring techniques in forward osmosis

    Full text link
    © 2019 by the authors. Forward osmosis has gained tremendous attention in the field of desalination and wastewater treatment. However, membrane fouling is an inevitable issue. Membrane fouling leads to flux decline, can cause operational problems and can result in negative consequences that can damage the membrane. Hereby, we attempt to review the different types of fouling in forward osmosis, cleaning and control strategies for fouling mitigation, and the impact of membrane hydrophilicity, charge and morphology on fouling. The fundamentals of biofouling, organic, colloidal and inorganic fouling are discussed with a focus on recent studies. We also review some of the in-situ real-time online fouling monitoring technologies for real-time fouling monitoring that can be applicable to future research on forward osmosis fouling studies. A brief discussion on critical flux and the coupled effects of fouling and concentration polarization is also provided

    A review of fouling mechanisms, control strategies and real-time fouling monitoring techniques in forward osmosis

    Get PDF
    Forward osmosis has gained tremendous attention in the field of desalination and wastewater treatment. However, membrane fouling is an inevitable issue. Membrane fouling leads to flux decline, can cause operational problems and can result in negative consequences that can damage the membrane. Hereby, we attempt to review the different types of fouling in forward osmosis, cleaning and control strategies for fouling mitigation, and the impact of membrane hydrophilicity, charge and morphology on fouling. The fundamentals of biofouling, organic, colloidal and inorganic fouling are discussed with a focus on recent studies. We also review some of the in-situ real-time online fouling monitoring technologies for real-time fouling monitoring that can be applicable to future research on forward osmosis fouling studies. A brief discussion on critical flux and the coupled effects of fouling and concentration polarization is also provided

    Fouling and Performance Investigation of Membrane Distillation at Elevated Recoveries for Seawater Desalination and Wastewater Reclamation.

    Get PDF
    This study reports on the impact of elevated recovery (i.e., 80%, 85%, and 90%) on the fouling and performance of air gap membrane distillation (AGMD) with real seawater and landfill leachate wastewater samples using polytetrafluoroethylene (PTFE) polymer membranes. Increasing the feed temperature from 55 °C to 65 °C improved the water flux of seawater and wastewater and shortened the operating time by 42.8% for all recoveries. The average water flux in the 80%, 85%, and 90% recovery experiments at the 65 °C feed temperature was 32%, 37.32%, and 36.7% higher than the case of 55 °C for the same recoveries. The water flux decline was more severe at a higher temperature and recovery. The highest flux decline was observed with a 90% recovery at 65 °C feed temperature, followed by an 85% recovery at 65 °C. Close examination of the foulants layer revealed that seawater formed a cake fouling layer made predominantly of metal oxides. In contrast, the landfill leachate fouling was a combination of pore blocking and cake formation, consisting mainly of carbonous and nitrogenous compounds. Physical cleaning with deionized (DI) water at 55 °C and 65 °C and chemical cleaning with hydrogen peroxide (H2O2) were investigated for their efficiency in removing membrane foulants. Analytical results revealed that seawater fouling caused membrane pore blockage while wastewater fouling formed a porous layer on the membrane surface. The results showed that membrane cleaning with hydrogen peroxide restored >97% of the water flux. Interestingly, the fouling factor in seawater tests was 10%, while it was 16% for the wastewater tests

    Iron slag/activated carbon-electrokinetic system with anolyte recycling for single and mixture heavy metals remediation.

    Get PDF
    The electrokinetic process has been proposed for in-situ soil remediation to minimize excavation work and exposure to hazardous materials. The precipitation of heavy metals in alkaline pH near the cathode is still challenging. Reactive filter media and enhancement agents have been used in electrokinetics to enhance the removal of heavy metals. This study investigated coupling industrial iron slag waste and iron slag-activated carbon reactive filter media with electrokinetic for a single and mixture of heavy metals treatment. Instead of using acid enhancement agents, the anolyte solution was recycled to neutralize the alkaline front at the cathode, reducing the operation cost and chemical use. Experiments were conducted for 2 and 3 weeks at 20 mA electric current. Copper removal increased from 3.11 % to 23 % when iron slag reactive filter media was coupled with electrokinetic. Copper removal increased to 70.14 % in the electrokinetic experiment with iron slag-activated carbon reactive filter media. The copper removal increased to 89.21 % when the anolyte solution was recycled to the cathode compartment. Copper removal reached 93.45 % when the reactive filter media-electrokinetic process with anolyte recirculation was extended to 3 weeks. The reactive filter media- an electrokinetic process with anolyte recycling was evaluated for removing copper, nickel, and zinc mixture, and results revealed 81.1 % copper removal, 89.04 % nickel removal, and 92.31 % zinc removal in a 3-week experiment. The greater nickel and zinc removal is attributed to their higher solubility than copper. The results demonstrated the cost-effectiveness and efficiency of the electrokinetic with iron slag-activated carbon reactive filter media with anolyte recirculation for soil remediation from heavy metals

    Sodium docusate as a cleaning agent for forward osmosis membranes fouled by landfill leachate wastewater.

    Full text link
    Membrane cleaning is critical for economic and scientific reasons in wastewater treatment systems. Sodium docusate is a laxative agent and removes cerumen (ear wax). Docusate penetrates the hard ear wax, making it softer and easier to remove. The same concept could be applied to soften and remove fouling layers on the membrane surface. Once softened, the foulants can be easily flushed with water. This innovative approach can address the challenge of developing superior methods to mitigate membrane fouling and material degradation. In this study, we evaluated the efficiency of sodium docusate for cleaning fouled forward osmosis membranes with real landfill leachate wastewater. Experiments were conducted to examine the impact of dose rate, contact time, flow or static conditions, and process configuration (forward osmosis (FO) or pressure retarded osmosis (PRO) upon fouling created by landfill leachate dewatering. A remarkable (99%) flux recovery was achieved using docusate at a small concentration of only 0.1% for 30 min. Furthermore, docusate can also effectively restore flux with static cleaning without using pumps to circulate the cleaning solution. Furthermore, cleaning efficiency can be achieved at neutral pH compatible with most membrane materials. From an economic and energy-saving perspective, static cleaning can almost achieve the same cleaning efficiency as kinetic cleaning for fouled forward osmosis membranes without the expense of additional pumping energy compared to kinetic cleaning. Since pumping energy is a major contributor to the overall energy of the forward osmosis system, it can be minimized to a certain degree by using a static cleaning approach and can bring good energy savings when using larger membrane areas. Studies of the contact angle on the membrane surface indicated that the contact angle was decreased compared to the fouled membrane after cleaning (e.g. 70.3° to 63.2° or FO mode and static cleaning). Scanning Electron Microscopy revealed that the cleaning strategy was successful. Infrared Spectroscopy showed that a small amount of sodium docusate remained on the membrane surface. Docusate is more environmentally friendly than acid or alkaline solutions from an environmental perspective. Furthermore, the cleaning solution can be reused for several cycles without discarding it due to the surfactant properties of docusate

    Metasurface-Based Wideband MIMO Antenna for 5G Millimeter-Wave Systems

    Get PDF
    This paper presents a metasurface based multiple-input multiple-output (MIMO) antenna with a wideband operation for millimeter-wave 5G communication systems. The antenna system consists of four elements placed with a 90 degree shift in order to achieve a compact MIMO system while a 2 x 2 non-uniform metasurface (total four elements) is placed at the back of the MIMO configuration to improve the radiation characteristics of it. The overall size of the MIMO antenna is 24 x 24 mm(2) while the operational bandwidth of the proposed antenna system ranges from 23.5-29.4 GHz. The peak gain achieved by the proposed MIMO antenna is almost 7dB which is further improved up to 10.44 dB by employing a 2 x 2 metasurface. The total efficiency is also observed more than 80% across the operating band. Apart from this, the MIMO performance metrics such as envelope correlation coefficient (ECC), diversity gain (DG), and channel capacity loss (CCL) are analyzed which demonstrate good characteristics. All the simulations of the proposed design are carried out in computer simulation technology (CST) software, and measured results reveal good agreement with the simulated one which make it a potential contender for the upcoming 5G communication systems
    corecore