18 research outputs found
L’effet de serre et le développement du Sud. Le cas de l’Amazonie
Le Brésil est lancé dans un fort développement économique. Il doit pourtant aussi, pour des raisons d’équilibre écologique global, prendre garde à ne pas surexploiter l’Amazonie. Comment concilier les deux sans faire reposer sur les pays du Sud des contraintes rendues impératives par un développement qui a profité au Nord ? Comment prendre en compte simultanément la vie des populations des régions amazoniennes, les intérêts nationaux brésiliens et l’enjeu climatique global
Teenage girls with type 1 diabetes have poorer metabolic control than boys and face more complications in early adulthood
Aims: To compare metabolic control between males and females with type 1 diabetes during adolescence and as young adults, and relate it to microvascular complications. Methods: Data concerning 4000 adolescents with type 1 diabetes registered in the Swedish paediatric diabetes quality registry, and above the age of 18 years in the Swedish National Diabetes Registry was used. Results: When dividing HbA1c values in three groups; amp;lt; 7.4% (57 mmol/mol), 7.4-93% (57-78 mmol/mol) and amp;gt;9.3% (78 mmol/mol), there was a higher proportion of females in the highest group during adolescence. In the group with the highest HbA1c values during adolescence and as adults, 51.7% were females, expected value 46.2%; in the group with low HbA1c values in both registries, 34.2% were females, p amp;lt; 0.001. As adults, more females had retinopathy, p amp;lt; 0.05. Females had higher mean HbAlc values at diagnosis, 112 vs. 10.9% (99 vs. 96 mmol/mol), p amp;lt; 0.03, during adolescence, 8.5 vs. 82% (69 vs. 66 mmol/mol) p amp;lt; 0.01, but not as young adults. Conclusions: Worse glycaemic control was found in adolescent females, and they had a higher frequency of microvascular complications. Improved paediatric diabetes care is of great importance for increasing the likelihood of lower mortality and morbidity later in life. (C) 2016 Elsevier Inc. All rights reserved.Funding Agencies|Association of Local Authorities and Regions, SALAR; Futurum - Academy for Health and Care, Jonkoping County Council, Sweden</p
Sensor-Augmented Insulin Pumps and Hypoglycemia Prevention in Type 1 Diabetes
Hypoglycemia can lead to seizures, unconsciousness, or death. Insulin pump treatment reduces the frequency of severe hypoglycemia compared with multiple daily injections treatment. The addition of a continuous glucose monitor, so-called sensor-augmented pump (SAP) treatment, has the potential to further limit the duration and severity of hypoglycemia as the system can detect and in some systems act on impending and prevailing low blood glucose levels. In this narrative review we summarize the available knowledge on SAPs with and without automated insulin suspension, in relation to hypoglycemia prevention. We present evidence from randomized trials, observational studies, and meta-analyses including nonpregnant individuals with type 1 diabetes mellitus. We also outline concerns regarding SAPs with and without automated insulin suspension. There is evidence that SAP treatment reduces episodes of moderate and severe hypoglycemia compared with multiple daily injections plus self-monitoring of blood glucose. There is some evidence that SAPs both with and without automated suspension reduces the frequency of severe hypoglycemic events compared with insulin pumps without continuous glucose monitoring
Sensor-Augmented Insulin Pumps and Hypoglycemia Prevention in Type 1 Diabetes
Hypoglycemia can lead to seizures, unconsciousness, or death. Insulin pump treatment reduces the frequency of severe hypoglycemia compared with multiple daily injections treatment. The addition of a continuous glucose monitor, so-called sensor-augmented pump (SAP) treatment, has the potential to further limit the duration and severity of hypoglycemia as the system can detect and in some systems act on impending and prevailing low blood glucose levels. In this narrative review we summarize the available knowledge on SAPs with and without automated insulin suspension, in relation to hypoglycemia prevention. We present evidence from randomized trials, observational studies, and meta-analyses including nonpregnant individuals with type 1 diabetes mellitus. We also outline concerns regarding SAPs with and without automated insulin suspension. There is evidence that SAP treatment reduces episodes of moderate and severe hypoglycemia compared with multiple daily injections plus self-monitoring of blood glucose. There is some evidence that SAPs both with and without automated suspension reduces the frequency of severe hypoglycemic events compared with insulin pumps without continuous glucose monitoring
Time spent in hypoglycemia is comparable when the same amount of exercise is performed 5 or 2 days weekly:A randomized crossover study in people with type 1 diabetes
Time spent in hypoglycemia is comparable when the same amount of exercise is performed 5 or 2 days weekly: a randomized crossover study in people with type 1 diabetes
IntroductionPeople with type 1 diabetes are recommended to exercise regularly. However, limited evidence exists on how frequency and duration of exercise affect the risk of hypoglycemia. The study aimed to compare the percentage of time spent in hypoglycemia between two 5-day periods with different frequency and duration of physical activity.Research design and methodsIn this outpatient randomized crossover study, 26 participants aged 18–65 years with type 1 diabetes for ≥2 years and insulin pump use for ≥1 year were included. After a 7-day observation period, participants completed two 5-day intervention periods separated by a washout period of at least 14 days. One period included five exercise sessions on 5 consecutive days (5S), each consisting of 4 min of resistance training and 30 min of aerobic exercise. Another period included two exercise sessions on 2 days with at least 2 days in between (2S), each consisting of 10 min of resistance training and 75 min of aerobic exercise. During each period, participants performed in total 150 min of aerobic exercise and 20 min of resistance training and wore continuous glucose monitors (Dexcom G6) and accelerometers (ActiGraph wGT3X-BT).ResultsTwenty insulin pump-treated adults (10 women) with type 1 diabetes completed the study. The baseline median (range) age was 48 (24–64) years, glycated hemoglobin 55 (44–66) mmol/mol, diabetes duration 24 (8–57) years, and body mass index 28.4 (22.3–35.8) kg/m2. No differences were observed between 5S and 2S in the percentage (mean±SD) of time spent below 3.9 mmol/L (3.5%±2.8% vs 4.5%±4.2%, p=0.28), time spent in 3.9–10.0 mmol/L (65.3%±15.0% vs 68.5%±13.6%, p=0.31), time spent above 10.0 mmol/L (31.2%±16.4% vs 27.3%±14.5%, p=0.15), mean glucose (8.7±1.3 mmol/L vs 8.5±1.2 mmol/L, p=0.33) and glycemic variability (35.8%±5.3% vs 35.8%±6.6%, p=0.97).ConclusionsTime spent in hypoglycemia was comparable between the two 5-day periods with different duration and frequency of physical activity.Trial registration numberNCT04089462.</jats:sec
Comparison of Continuous Glucose Monitoring Accuracy Between Abdominal and Upper Arm Insertion Sites
Comparison of Continuous Glucose Monitoring Accuracy Between Abdominal and Upper Arm Insertion Sites
Preserved glucose response to low-dose glucagon after exercise in insulin-pump-treated individuals with type 1 diabetes:a randomised crossover study
Low-Carbohydrate Diet Impairs the Effect of Glucagon in the Treatment of Insulin-Induced Mild Hypoglycemia:A Randomized Crossover Study
OBJECTIVE
This study compared the ability of glucagon to restore plasma glucose (PG) after mild hypoglycemia in patients with type 1 diabetes on an isocaloric high-carbohydrate diet (HCD) versus a low-carbohydrate diet (LCD).
RESEARCH DESIGN AND METHODS
Ten patients with insulin pump–treated type 1 diabetes randomly completed 1 week of the HCD (≥250 g/day) and 1 week of the LCD (≤50 g/day). After each week, mild hypoglycemia was induced by a subcutaneous insulin bolus in the fasting state. When PG reached 3.9 mmol/L, 100 µg glucagon was given subcutaneously, followed by 500 µg glucagon 2 h later.
RESULTS
Compared with the HCD, the LCD resulted in lower incremental rises in PG after the first (mean ± SEM: 1.3 ± 0.3 vs. 2.7 ± 0.4 mmol/L, P = 0.002) and second glucagon bolus (4.1 ± 0.2 vs. 5.6 ± 0.5 mmol/L, P = 0.002). No differences were observed between the diets regarding concentrations of insulin, glucagon, and triglycerides.
CONCLUSIONS
The LCD reduces the treatment effect of glucagon on mild hypoglycemia. Carbohydrate intake should be considered when low-dose glucagon is used to correct hypoglycemia.
</jats:sec
