50 research outputs found
Development of technology for hot drape forming and nozzles for torus sections Final report, Jun. 1963 - Dec. 1965
Hot drape forming and heat treatment of aluminum base alloy toroidal shell segment
The Effect of Induced Intraocular Stray Light on Recognition Thresholds for Pseudo-High-Pass Filtered Letters
PURPOSE: The Moorfields Acuity Chart (MAC)—comprising pseudo-high-pass filtered “vanishing optotype” (VO) letters—is more sensitive to functional visual loss in age-related macular degeneration (AMD) compared to conventional letter charts. It is currently unknown the degree to which MAC acuity is affected by optical factors such as cataract. This is important to know when determining whether an individual's vision loss owes more to neural or optical factors. Here we estimate recognition acuity for VOs and conventional letters with simulated lens aging, achieved using different levels of induced intraocular light scatter. METHODS: Recognition thresholds were determined for two experienced and one naive participant with conventional and VO letters. Stimuli were presented either foveally or at 10 degrees in the horizontal temporal retina, under varying degrees of intraocular light scatter induced by white resin opacity-containing filters (WOFs grades 1 to 5). RESULTS: Foveal acuity only became significantly different from baseline (no filter) for WOF grade 5 with conventional letters and WOF grades 4 and 5 with VOs. In the periphery, no statistical difference was found for any stray-light level for both conventional and VOs. CONCLUSIONS: Recognition acuity measured with conventional and VOs is robust to the effects of simulated lens opacification, and thus its higher sensitivity to neural damage should not simultaneously be confounded by such optical factors. TRANSLATIONAL RELEVANCE: The MAC may be better able to differentiate between neural and optical deficits of visual performance, making it more suitable for the assessment of patients with AMD, who may display both types of functional visual loss
Ageing changes in retinal outer nuclear layer thickness and cone photoreceptor density using adaptive optics-free imaging
Purpose: To investigate age-related changes of the outer nuclear layer (ONL) thickness and cone density, and their associations in healthy participants using a modified, narrow scan-angle Heidelberg Retina Angiograph (HRA2). Methods: Retinal cones were imaged outside the fovea at 8.8° eccentricity and cone density was compared to ONL thickness measurements obtained by Spectral-Domain Optical Coherence Tomography (SD-OCT) at the same locations. Fifty-six eyes of 56 healthy participants with a median age (interquartile range, IQR) of 37 years (29–55) were included. Results: Median (IQR) cone count was 7,472 (7,188, 7,746) cones/mm2 and median (IQR) ONL thickness was 56 (52, 60) µm for healthy participants. Both cone density and ONL thickness were negatively associated with age: cone density, R2 = 0.16 (F(1,54) = 10.41, P = 0.002); ONL thickness, R2 = 0.12 (F(1,54) = 7.41, P = 0.009). No significant association was seen between cone density and ONL thickness (R2 = 0.03; F(1,54) = 1.66, P = 0.20). Conclusion: Cone density was lower, and ONL thinner, in older compared to younger participants, therefore, image-based structural measures should be compared to age-related data. However, cone density and ONL thickness were not strongly associated, indicating that determinants of ONL thickness measurements other than cone density measurements, and including measurement error, have a major influence
Controversies in the Use of MIGS
Abstract
Minimally invasive glaucoma surgery (MIGS) has fulfilled an unmet need in the management of glaucoma. This chapter highlights some controversial issues regarding the use of MIGS in clinical practice, including (1) whether there is sufficient evidence to advocate combining MIGS with cataract surgery over cataract surgery alone, (2) the merits and drawbacks of different approaches to trabecular bypass and canal-based MIGS procedures, (3) the effect of MIGS on endothelial cell loss, (4) suprachoroidal MIGS devices and whether there is still a role for these procedures, and (5) a comparison between subconjunctival MIGS and trabeculectomy. Several questions are still left unanswered and hopefully, further research and more clinical experience with these new technologies will help improve surgical outcomes for patients
Vasculitis-like hemorrhagic retinal angiopathy in Wegener’s granulomatosis
Background: Granulomatosis with polyangiitis, also known as Wegener’s granulomatosis, is a chronic systemic inflammatory disease that can also involve the eyes. We report a case of massive retinal and preretinal hemorrhages with perivascular changes as the initial signs in granulomatosis with polyangiitis (Wegener’s granulomatosis).
Case presentation: A 39-year-old Caucasian male presented with blurred vision in his right eye, myalgia and arthralgia, recurrent nose bleeds and anosmia. Fundus image of his right eye showed massive retinal hemorrhages and vasculitis-like angiopathy, although no fluorescein extravasation was present in fluorescein angiography. Laboratory investigations revealed an inflammation with increased C-reactive protein, elevated erythrocyte sedimentation rate and neutrophil count. Tests for antineutrophil cytoplasmic antibodies (ANCA) were positive for c-ANCA (cytoplasmatic ANCA) and PR3-ANCA (proteinase 3-ANCA). Renal biopsy demonstrated a focal segmental necrotizing glomerulonephritis. Granulomatosis with polyangiitis (Wegener’s granulomatosis) was diagnosed and a combined systemic therapy of cyclophosphamide and corticosteroids was initiated. During 3 months of follow-up, complete resorption of retinal hemorrhages was seen and general complaints as well as visual acuity improved during therapy.
Conclusion: Vasculitis-like retinal changes can occur in Wegener’s granulomatosis. Despite massive retinal and preretinal hemorrhages that cause visual impairment, immunosuppressive therapy can improve ocular symptoms
Comparative study of trabeculectomy using single sutures versus releasable sutures
BACKGROUND: The purpose of this study was to compare the outcomes of trabeculectomy using single sutures or releasable sutures.
METHODS: This retrospective study analyzed the medical records of 61 patients who had undergone trabeculectomy using single sutures (n = 33, 54.1%) or releasable sutures (n = 28, 45.9%). The scleral flap was secured with a mean 3.9 (range 3-5) single sutures in 33 patients and with three releasable sutures in 28 patients. Primary outcomes were the success rate, based on intraocular pressure and medication usage, and the frequency of complications and post-surgical interventions. The criteria used to determine complete success were, first, intraocular pressure =20% intraocular pressure reduction without glaucoma medication.
RESULTS: All patients had an intraocular pressure <= 21 mmHg; 87.5% in the single suture group and 92.6% in the releasable suture group had an intraocular pressure < 18 mmHg at 24 months. There was a highly significant reduction in intraocular pressure to baseline values in both groups at the last visit. Applying the first criterion, complete success was achieved in 57.6% of patients with single sutures and 71.4% with releasable sutures, and based on the second criterion, 66.7% and 71.4%, respectively. No significant difference was found between the groups with regard to intraocular pressure, or success or complication rates.
CONCLUSION: The results of trabeculectomy using single sutures or releasable sutures are equivalent. Therefore, the choice of suture technique should be based on individual patient requirements and surgeon experience
Quality of life following glaucoma surgery: canaloplasty versus trabeculectomy
Purpose: To evaluate quality of life (QoL) with a new questionnaire after canaloplasty (CP) and trabeculectomy (TE).
Patients and methods: We assessed outcomes of surgery, rate of revision surgeries, patients’ mood, and influence of postoperative care on QoL, surgery interference with daily activities, and postsurgical complaints. Patients completed the QoL questionnaire 24 months after surgery.
Results: Patients who underwent CP (n=175) were compared to TE patients (n=152). In the CP group, 57% of patients expressed high satisfaction, while 41% of patients in the TE group said they were highly satisfied. The satisfaction difference was statistically significant (P=0.034). Significantly fewer second surgeries were needed after CP (8% CP versus 35% TE, P<0.001). Patients were more positive in the CP group (54% CP versus 37% TE, P<0.009). Stress related to postoperative care was lower in the CP group compared to the TE group (14% versus 46%). Difficulties with activities of daily living, such as reading, were much lower or even nonexistent after CP, and complaints like eye burning or stinging were significantly lower in the CP group.
Conclusions: Compared with TE, CP is associated with less QoL impairment and higher patient satisfaction after surgery. However, long-term data on intraocular pressure reduction after surgery are needed to confirm long-term patient satisfaction with this surgery
